eyebrow Docs · Using the client
lede connectTo() opens a connection from a plain config array — no entry in config/opcua.php required. The right tool for fleet-style deployments where endpoints are discovered at runtime.
see_also
href meta
./named-connections.md
5 min
href meta
../configuration/connections.md
8 min
href meta
./connection-lifecycle.md
5 min
prev
label href
Named connections
./named-connections.md
next
label href
Connection lifecycle
./connection-lifecycle.md

Ad-hoc connections

Opcua::connectTo() opens a connection from a plain PHP array without needing an entry in config/opcua.php. Use it when the endpoint is genuinely dynamic — discovered from a fleet registry, derived from a request parameter, or coming from another system.

The signature

The endpoint URL is the first positional argument, not a key inside the config array:

Opcua::connectTo(
    string $endpointUrl,
    array $config = [],
    ?string $as = null,
): OpcUaClientInterface

The shape

use PhpOpcua\LaravelOpcua\Facades\Opcua;

$client = Opcua::connectTo(
    endpointUrl: "opc.tcp://plc-{$serial}.factory.local:4840",
    config:      ['timeout' => 5.0],
);

$dv = $client->read('ns=2;s=Speed');

The $config array accepts the same keys as a connections.* entry in config/opcua.php (except for endpoint, which is the first argument). Missing keys take sensible defaults (security policy None, anonymous, default timeout).

If you intend to retrieve the same client later (or close it by name), pass an $as label:

$client = Opcua::connectTo('opc.tcp://...', $cfg, as: 'plc-line-a');
// ...later:
Opcua::connection('plc-line-a');  // same instance
Opcua::disconnect('plc-line-a');

Without an $as, the manager keys the connection internally as 'ad-hoc:' . $endpointUrl.

Why not just use named connections?

Named connections are best when the set is closed and known ahead of time. Ad-hoc is best when the set is open:

Scenario Use
Three PLCs in a fixed plant layout Named connections
One historian per tenant, configured statically Named connections
200-PLC fleet discovered from a registry Ad-hoc
User-provided endpoint (operator tool) Ad-hoc
Edge gateway that connects to whichever PLC is online Ad-hoc

The line: does the config live in code (config/opcua.php) or in data (a database, a registry, a request)?

Caching identity

connectTo() stores the resulting client under a name. Two calls with the same $as (or, when $as is null, the same endpointUrl) return distinct ad-hoc connections in the manager — but if you pass the same name, the second connectTo() creates a new client and overwrites the cached one. To reuse the cached client, call Opcua::connection($as) instead:

$a = Opcua::connectTo('opc.tcp://plc-1:4840', as: 'plc-1');
$b = Opcua::connection('plc-1');
// $a === $b

Disconnecting an ad-hoc client

disconnect() takes the name (string), not the client instance:

Opcua::connectTo('opc.tcp://plc-1:4840', as: 'plc-1');
// ...
Opcua::disconnect('plc-1');          // by name
// OR
Opcua::disconnectAll();              // closes everything

There is no overload that accepts a client instance — use the $as name (or 'ad-hoc:' . $endpointUrl if you didn't pass one). In managed mode, disconnect() also tells the daemon to close the underlying session.

Fleet pattern

class FleetReader
{
    public function __construct(
        private readonly OpcuaManager $opcua,
        private readonly PlcRegistry  $registry,
    ) {}

    public function readSpeed(string $plcSerial): ?float
    {
        $entry = $this->registry->findOrFail($plcSerial);

        $client = $this->opcua->connectTo(
            endpointUrl: $entry->endpoint,
            config: [
                'security_policy'    => $entry->security_policy,
                'security_mode'      => $entry->security_mode,
                'client_certificate' => $entry->cert_path,
                'client_key'         => $entry->key_path,
                'username'           => $entry->username,
                'password'           => $entry->password,
                'timeout'            => 8.0,
            ],
            as: 'plc-' . $plcSerial,
        );

        return $client->read('ns=2;s=Speed')->getValue();
    }
}

PlcRegistry is your domain. The package doesn't define a storage shape for it — store the fleet in Eloquent, in Redis, in a config file, wherever fits your operational picture.

Caveat — credentials in config arrays

A config array passed to connectTo() contains plaintext credentials. Two implications:

  1. Don't log it. The package never logs config payloads, but if your application code does (e.g. Log::debug($config)), secrets leak.
  2. Don't serialise it. The same constraint as Facade vs injection — don't store a config array in a job's properties unless you accept that it ends up on the queue, on disk, and in Horizon's UI.

The right shape for queued jobs is to store the registry key, re-resolve credentials from the registry inside handle():

class SamplePlc implements ShouldQueue
{
    public function __construct(public string $plcSerial) {}

    public function handle(FleetReader $reader): void
    {
        $speed = $reader->readSpeed($this->plcSerial);
        // ...
    }
}

When the endpoint comes from a user

If the endpoint URL is user-controlled (admin tool, operator interface), validate it before passing to connectTo():

$request->validate([
    'endpoint' => [
        'required',
        'string',
        'starts_with:opc.tcp://',
        // narrow further: allowed hostnames, allowed port ranges
        function (string $attr, string $value, Closure $fail) {
            $parts = parse_url($value);
            if (!str_ends_with($parts['host'] ?? '', '.factory.local')) {
                $fail('Endpoint must be on the factory network.');
            }
        },
    ],
]);

The package doesn't sandbox connections — if you pass a config, the package tries to open it. Network-layer egress filtering is the right place for the hard guarantee.

Mixed style

Named connections and ad-hoc connections coexist freely. A typical multi-plant deployment has:

  • Named: historian, mes, scada-gateway — fixed infrastructure.
  • Ad-hoc: per-PLC clients resolved from a fleet registry.

Opcua::connection('historian') and Opcua::connectTo([...]) resolve through the same manager and share connection caching.

Where to read next