docs/loadflow/parameters.md

+6
Original file line numberDiff line numberDiff line change
@@ -170,6 +170,12 @@ either have different target voltages, then their voltage control is disabled if
170170
set to `false`, then only the control of the first generator is kept and applied to all the other generators.
171171
The default value is `false`.
172172

173+
**remoteVoltageControlIgnoreQPercent**
174+
Whether remote voltage control should ignore the qPercent data, an optional input that provides a repartition key for reactive power
175+
in case several bus control the same target, and systematically use the default repartition key instead which is based on reactive
176+
power range. The default value is `false`.
177+
178+
173179
**secondaryVoltageControl**
174180
Whether simulation of secondary voltage control should be enabled.
175181
Modeling of secondary voltage control has been designed to provide a fast, static, approximation of the equilibrium state of the generator reactive power