Skip to content

Check for incorrectly specified inlets #638

Open
@g-rydquist

Description

@g-rydquist

The newly added inlet BC does not have any check to make sure the inlet velocity is actually flowing into the domain. Instead, an out-flowing velocity would be handled as a subsonic inlet. Some type of check should be added to check for this.