2025-06-08 05:09:35,301:INFO: SMT triggers limit function: 8.9 -> -3.7: skipped
2025-06-08 05:09:32,717:INFO: SMT triggers limit function: 12.1 -> 1.4: executed
2025-06-08 05:09:32,717:INFO: Sun: 05:19 - 21:41 Demand: 196.4W, Panel DC: (0.0W), Hub DC: (195.0W), Inverter Limit: 392.0W, Hub Limit: 850.0W
2025-06-08 05:09:32,717:INFO: Setting inverter output limit to 392W (1 min moving average of 98W x 4)
2025-06-08 05:09:32,717:INFO: Solarflow is willing to contribute 98.0W (per channel) of the requested 196.4!
2025-06-08 05:09:32,717:INFO: Not setting solarflow output limit to 850.0W as it is identical to current limit!
2025-06-08 05:09:32,717:INFO: Based on time, solarpower ( 0.0W) minimum charge power (10W) and bypass state (False), hub could contribute 196.4W - Decision path: 1.3.1. (not enough power to cover demand and minimum charge power during night/dusk/dawn)
2025-06-08 05:09:32,716:INFO: Direct connected panel are producing 0.0W, trying to get 196.4W from hub.
2025-06-08 05:09:32,716:INFO: SFC: BatteryTarget: charging, SoC at sunrise: 2, SoC increase: 33
2025-06-08 05:09:32,716:INFO: SMT: T:Smartmeter P:-4.0W [ 23.5,23.5,21.1,18.0,12.1,1.4 ]
2025-06-08 05:09:32,716:INFO: INV: AC:196.1W, DC:206.5W (0.6|0.6|105.2|100.1), L:380W (94.9W/channel) [1500W]
2025-06-08 05:09:32,716:INFO: HUB: S:0.0W [ 0.0 ], B: 1% ( 1| 1| 1| 2) low: 0 high: 100 target: charging, V:47.1V (47.1|46.9|47.2|47.2), C:-196W, P:False (manual, possible), F:34.5h, E:-1.0h, CT:ON (120hrs) discharging, H:187W, L:850W
Hey,
I noticed on the latest master build that in the morning the HUB stops ingesting energy, as the - probably- the logic hits that the dusk SoC is taken and certain amount shall be charged to be batteries before discharging again.
From the above log: