Description
RFC 4108 includes this syntax:
FirmwarePackageLoadReceipt ::= SEQUENCE {
version FWReceiptVersion DEFAULT v1,
hwType OBJECT IDENTIFIER,
hwSerialNum OCTET STRING,
... }
FWReceiptVersion ::= INTEGER { v1(1) }
When I used asn1ate to compile the module, it did not handle this part properly.
It produced:
class FWReceiptVersion(univ.Integer):
pass
FWReceiptVersion.namedValues = namedval.NamedValues(
('v1', 1)
)
FirmwarePackageLoadReceipt.componentType = namedtype.NamedTypes(
namedtype.DefaultedNamedType('version', FWReceiptVersion().subtype(value=v1)),
namedtype.NamedType('hwType', univ.ObjectIdentifier()),
namedtype.NamedType('hwSerialNum', univ.OctetString()),
... )
It should have produced:
class FWReceiptVersion(univ.Integer):
pass
FWReceiptVersion.namedValues = namedval.NamedValues(
('v1', 1)
)
FirmwarePackageLoadReceipt.componentType = namedtype.NamedTypes(
namedtype.DefaultedNamedType('version', FWReceiptVersion().subtype(value='v1')),
namedtype.NamedType('hwType', univ.ObjectIdentifier()),
namedtype.NamedType('hwSerialNum', univ.OctetString()),
....
)