  • Motor Control Protocol Suite implements drive and monitor functionality
  • Controller: host PC or other mcu sending motor control commands
  • Performer: stm32 motor controller
  • ASPEP used as low level protocol that then feeds into the Motor Control Protocol that controls the motor
  • MCP requires the low level protocol have 2 independent communication channels
    • Must specify which channel the data comes from when it reaches MCP
  • MCP does not provide message segmentation features, all data must be sent in one message
  • MCP designed to minimze the amount of computing power needed by performer to operate it
  • 4 services:
    • Command: Controller sends command to Performer to execute. performer returns a status and other data (ie START_MOTOR)
    • Registery: Formalizes the access to the internal variables and state of Performer
      • Registers let Controller read measurements, write run time parameters, or trigger actions
      • ie Ia that monitors phase A current, CONTROL_MODE REGISTER, OR speed_ramp
    • Datalog: Lets Controller monitor chaning values of registers in a controlled way, and allows for plotting in real time
    • Notification: Allows Controller to be notified when values of a set register change, ie STATUS register
  • Command Service
    • 3 core commands for all MCP implementations:
    • 1 user defined command
    • Command indentified by Command ID and can have additional data
    • Immediately executed by Performer adn return status + data
    • Only 1 command can be pending at a time
    • Command service uses ysnchronous channel of the lower level protocol: command and response messages are transferred on this channel
    • Command format:
      • 0-3 bits: Motor #
        • 0 = all motors
      • 3-16 bits: Command ID
      • 16-(16+8*N): Command Payload
    • Response message:
      • N bytes: Response Payload
      • N - N+8 bits: Status Code
        • See table Table 1: Common MCP command status codes in documentation
  • Registry service
    • Registers are a way to provide application on the Controller side with variables, state, and other data
    • register identifier
      • 0-3 bites: motor #
      • 3-6 bits: info on size of value of data element (8,16,132)
      • 6-16 bits: identifier: uniquely identify register of given type
    • The full list of registers depends of the application and can change in time: new registers are added periodically to go with the evolution of the MCSDK
  • Datalog service
    • periodic recording by Performer of values of a number of registers that are then trasnmitted to Controller
    • Controler can configure the number of registers to record, their identifiers and sampling frequency
    • recorded values are accumulated and sent by the performer to controller in a datalog message
    • Datalog service uses an asynchronous channel of the low level protocol
    • Datalog service is optional
    • high freq registers recorded as 16bit values, medium frequency registers recorded as 32bit values
    • timestamp field is 32bit counter incremented on high freq task execution
      • can be used to detect if data is lost between 2 datalog messages
    • Async Datalog ID field is set to 0, and identifies the message as a Datalog message
    • Mark field identifies the configuration of the datalog service corresponding to the content of the Datalog message
      • Value set by controller at configuration time, 8bit integer that can't be 0
      • This value is useful when changing from one Datalog configuration to another
        • ie Controller changes the Datalog service configuration
  • ASPEP (asymemetric serial packet exchange protocol)
    • point to point protocol
    • involves 2 Hosts, a Controller, and a Performer that exchange Packets
    • Controller initiates the connection
    • Performer is stm32 that only responds
    • Packet made of 4 byte header followed by a Payload
      • Size of payload indicated in header
    • First, the Controller initiates connection to the Performer
      • purpose is to negotiate the values of a set of parameters that are needed for the connection to work, mainly maximum packet sizes and other protocol options
    • 3 communication channels:
      • Synchronous: mainly for sending commands from controller to performer
        • Controller sends a DATA packet
        • Performer sends back a RESPONSE packet
      • Asynchronous: Allows Performer to send ASYNC packets
        • used to send real-time data
      • Control: used to establish and manage connection. 3 packets used are BEACON, PING, and ERROR
        • Connection establishment procedure involves BEACON and PING
        • Keep-alive feature uses PING packet
        • Recovery procedure handles cases where transmission issues encountered. Allows for recovering the synchronization and communication
      • 3 channels are multiplexed over the serial link with different priorities: synchronous > control > asynchronous
    • optional 16-bit CRC
    • Packet structure:
      • Header: 4 bytes
        • 0-4 bits: type field
          • BEACON
          • PING
          • ERROR
          • REQUEST
          • RESPONSE
          • ASYNC
        • 4-28 bits: header content
        • 28-32 bits: CRCH
          • CRC check computed on first 28 bits of the header