Skip to content

ORCA hangs when handing over with triggers enabled at low voltage #530

@tannerbk

Description

@tannerbk

In order to reproduce:

  1. Enable triggers on any crate at low voltage.
  2. Save and close Orca
  3. Open Orca and you should see a message: "Crate 11 HV is not at nominal voltage, but triggers are currently enabled"
  4. Click "Yes" to disable to the triggers
    Then Orca hangs. I found clicking "No" allowed you to get rid of the message(s) and then you can just turn off triggers the normal way.