Notifications
You must be signed in to change notification settings - Fork 2
Open
Description
On the t2/t2.nii.gz data, fslhd gives:
qform_code 2
qto_xyz:1 0.000000 0.000000 1.000000 -32.219284
qto_xyz:2 -1.000000 0.000000 -0.000000 31.786606
qto_xyz:3 0.000000 1.000000 -0.000000 -19.321671
qto_xyz:4 0.000000 0.000000 0.000000 1.000000
qform_xorient Anterior-to-Posterior
qform_yorient Inferior-to-Superior
qform_zorient Left-to-Right
sform_name Aligned Anat
sform_code 1
sto_xyz:1 0.000000 0.000000 1.000000 -32.219284
sto_xyz:2 -1.000000 0.000000 0.000000 31.786606
sto_xyz:3 0.000000 1.000000 0.000000 -19.321671
sto_xyz:4 0.000000 0.000000 0.000000 1.000000
qform_code=2 means that the physical coordinate system is "unknown" and that some software will then consider the sform instead.
I think we should set the qform_code=1 for our testing data, because this is how we expect NIFTI header to be presented to SCT's functions.
Related to spinalcordtoolbox/spinalcordtoolbox#3283
Metadata
Metadata
Assignees
Labels
No labels