There are a number of MCNP parameters that can be specified for individual cells such as FCL, ELPT, and BFLCL. These parameters work just like IMP in that it is possible to specify them in either the cell block or the data block, and they may also have particle identifiers; e.g. FCL:n, FCL:p. The MCNP importer does not recognize any of these parameters.