Summary
Document how the Tier 0 metadata tier mirrors metadata across a node's local drives (D+x) and how that copy count follows the system redundancy level.
Type
Conceptual
Suggested Content
- Audience: Admins sizing or deploying controller nodes
- Prerequisites: Understanding vSAN Redundancy Levels
- Key sections:
- Metadata matches system resilience locally: N+1 → 2 local copies (D+1), N+2 → 3 local copies (D+2)
- Copy count is capped by T0 drives present per node: 1 drive → 1 copy, 2 drives → 2 copies, 3+ drives → 3 copies
- Usable T0 capacity ≈ one drive's size; additional drives hold mirror copies (e.g. 2 × 1.6TB → ~1.6TB usable)
- Sizing implication: N+2 systems need 3 T0 drives per controller node for metadata resilience to match the system level
- Suggested location: extend the vSAN Redundancy Levels page or the Tier 0 section of Storage Tiers
Context
Requested via support interaction. Behavior confirmed by engineering; current docs cover only cross-node copy counts (N+1/N+2), not the metadata tier's local drive mirroring.
Summary
Document how the Tier 0 metadata tier mirrors metadata across a node's local drives (D+x) and how that copy count follows the system redundancy level.
Type
Conceptual
Suggested Content
Context
Requested via support interaction. Behavior confirmed by engineering; current docs cover only cross-node copy counts (N+1/N+2), not the metadata tier's local drive mirroring.