forked from Koyot-Digital/Wiki
-
Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathstartup.html
More file actions
282 lines (258 loc) · 12.8 KB
/
Copy pathstartup.html
File metadata and controls
282 lines (258 loc) · 12.8 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
<!DOCTYPE html>
<html lang="en">
<head>
<!-- Cookie Consent by TermsFeed https://www.TermsFeed.com -->
<script type="text/javascript" src="https://www.termsfeed.com/public/cookie-consent/4.2.0/cookie-consent.js"
charset="UTF-8"></script>
<script type="text/javascript" charset="UTF-8">
document.addEventListener('DOMContentLoaded', function () {
cookieconsent.run({ "notice_banner_type": "simple", "consent_type": "express", "palette": "dark", "language": "en", "page_load_consent_levels": ["strictly-necessary"], "notice_banner_reject_button_hide": false, "preferences_center_close_button_hide": false, "page_refresh_confirmation_buttons": false, "website_name": "ONPS Wiki" });
});
</script>
<!-- Google Analitics -->
<script type="text/plain" data-cookie-consent="tracking" async
src="https://www.googletagmanager.com/gtag/js?id=G-8C0MST73WK"></script>
<script type="text/plain" data-cookie-consent="tracking">
window.dataLayer = window.dataLayer || [];
function gtag(){dataLayer.push(arguments);}
gtag('js', new Date());
gtag('config', 'G-8C0MST73WK');
</script>
<!-- end of Google Analitics-->
<noscript>Free cookie consent management tool by <a href="https://www.termsfeed.com/">TermsFeed</a></noscript>
<!-- End Cookie Consent by TermsFeed https://www.TermsFeed.com -->
<!-- Below is the link that users can use to open Preferences Center to change their preferences. Do not modify the ID parameter. Place it where appropriate, style it as needed. -->
<!-- Primary Meta Tags -->
<meta name="title" content="ONPS - Startup Guide" />
<meta name="description" content="Oakridge Nuclear Power Station - Startup Guide" />
<!-- Open Graph / Facebook -->
<meta property="og:type" content="website" />
<meta property="og:url" content="https://wiki.koyot.digital/startup.html" />
<meta property="og:title" content="ONPS - Startup Guide" />
<meta property="og:description" content="Oakridge Nuclear Power Station - Startup Guide" />
<meta property="og:image" content="/images/Startup.webp" />
<!-- X (Twitter) -->
<meta property="twitter:card" content="summary_large_image" />
<meta property="twitter:url" content="https://wiki.koyot.digital/startup.html" />
<meta property="twitter:title" content="ONPS - Startup Guide" />
<meta property="twitter:description" content="Oakridge Nuclear Power Station - Startup Guide" />
<meta property="twitter:image" content="/images/Startup.webp" />
<meta charset="UTF-8" />
<meta name="viewport" content="width=device-width, initial-scale=1" />
<title>Oakridge Nuclear Power Station - Pre-Start Guide</title>
<script src="https://kit.fontawesome.com/a7bdae1ce6.js" crossorigin="anonymous"></script>
<link rel="apple-touch-icon" sizes="180x180" href="/images/Favicon/apple-touch-icon.png">
<link rel="icon" type="image/png" sizes="32x32" href="/images/Favicon/favicon-32x32.png">
<link rel="icon" type="image/png" sizes="16x16" href="/images/Favicon/favicon-16x16.png">
<link rel="manifest" href="/site.webmanifest">
<link rel="stylesheet" href="css/style.css" />
<link rel="stylesheet" href="css/calculator.css" />
<script src="https://cdn.jsdelivr.net/npm/mathjax@3/es5/tex-mml-chtml.js"></script>
</head>
<header id="header" style="
display: flex;
justify-content: space-between;
align-items: center;
padding: 8px;
">
<div style="display: flex; gap: 12px; align-items: center;">
<img src="images/home.svg" style="width: 24px; height: 24px; cursor: pointer;" onclick="relocate('index.html');">
<img src="images/settings.svg" style="width: 24px; height: 24px; cursor: pointer;"
onclick="relocate('settings.html');">
</div>
<h2 style="margin: 0;">Oakridge Nuclear Power Station Wiki</h2>
</header>
<body>
<header class="hero small-hero">
<div class="hero-overlay"></div>
<img src="images/Startup.webp" alt="Pre-Start Reactor" />
<div class="hero-content">
<h1>Start-Up Guide</h1>
<p>Prepare the RBMK-1500 reactor for a safe and stable startup by completing the Pre-Startup Checklist and
configuring all supporting systems.</p>
</div>
</header>
<main class="container">
<div id="NavGrid-placeholder"></div>
<section class="location-section">
<br>
<h2>Stage One Startup</h2>
<br>
<ul>
<li>Grab a bypass key from the key cabinet at the door of the Control Room.</li>
<li>Insert the key into the Auto-scram panel and disable Auto-scram.</li>
<li>Enable Reactor Mode 1.</li>
<li>Close Heat Exchanger A and B.</li>
<li>Disable OCC Circulation Pumps 1 and 2.</li>
<li>Mode Conflict alarm will flash, press the acknowledge button on the Middle Reactor Console. </li>
<li>Enable Shutdown Control Rods.</li>
<li>Click the Reset button next to the acknowledge button on the Middle Reactor Console. </li>
<li>Wait for the Out of Zone panel to flash, a bell will ring signalling the Shutdown Rods are fully removed.
</li>
<li>Enable Auto Control Rods.<p>
<li>Type the numbers <strong>1500</strong> into the keypad next to the Auto Control Rods switch and click the
grey button to set.<p>
<li>Once the reactor reaches 1500 MW enable Reactor Mode 2. Keep an eye on the Core Heat Distribution.</li>
<li>Enable Feedwater Pump 1 and set it to speed 2.</li>
<li>Enable Condensate Pump 1 and set it to speed 2.</li>
</ul>
<br>
<h2>Stage Two Startup</h2>
<p>Withdraw Control Rods until power reaches <strong>2100</strong> MW.
<p>
<h3>Turbine A Run-up</h3>
<br>
<ul>
<li>Call Engineering, click Turning gear, and disengage Turbine A. </li>
<li>At the Turbine Panel enable the Synchroscope for Turbine A.</li>
<li>Reduce Turbine A bypass valve to around <strong>20-30%</strong> at the Turbine Panel.</li>
<li>Slowly increase the Turbine Valve to around <strong>60-70%</strong></li>
<li>The RPM should start rising, it should add 30 to the RPM every time it updates.</li>
<li>Open the Grid Sync cap.</li>
<li>Once the RPM reaches above +1770 RPM the Synchroscope will flash and make an audible sound when the needle
passes over the red zone at the top of the gauge.</li>
<li>Once the needle slows down and the RPM is around 1800, wait for the green light to light up and then click
Grid Sync.</li>
<li>If you synced it correctly the RPM will stabilize at 1800.</li>
</ul>
<br>
<h3>If sync is unsuccessful</h3>
<br>
<ul>
<li>Click the Acknowledge button, the corresponding one to silence the Turbine Trip Alarm will be glowing.</li>
<li>Wait for the RPM to drop below 600.</li>
<li>Click the reset button next to the Acknowledge button you just pressed.</li>
<li>Retry the Turbine Sync Process.</li>
</ul>
<br>
<h3>If sync is successful</h3>
<br>
<ul>
<li>Acknowledge the Reverse Power alert.</li>
<li>Increase the Turbine Valve <strong>SLOWLY</strong> to 100%.</li>
<li>Decrease the Bypass valve to 0%.</li>
<li>Once the generator load is positive, click the Reset button next to the Acknowledge button.</li>
</ul>
<ul>
<li>Enable Breaker 64 A-M.</li>
<li>Call Engineering and click Reset Breakers.</li>
<li>Set both Deaerator A and B Relief Valves to 25%.</li>
<li>Set both Deaerator A and B Inlet Valves to 45%.</li>
<li>Enable Condensate Pump 2.</li>
<li>Enable Feedwater Pump 2.</li>
<li>Open Deaerator A-B Bleed Valve.</li>
</ul>
<br>
<h2>Stage Three Startup</h2>
<ul>
<li>Set Main Circulation Pumps A1 and A2 to speed 3.</li>
<li>Enable Main Circulation Pumps B1 and B2.</li>
<li>Set Condenser Coolant Pumps A1 and A2 to speed 3.</li>
<li>Type the numbers <strong>3000</strong> into the Auto Control Rod panel and click the grey button.</li>
<li>Withdraw Control rods until power reaches 3000 MW, Keep an eye on Core Heat Distribution.</li>
<li>Enable Condenser Coolant Pumps B1 and B2 and set to speed 3.</li>
</ul>
<br>
<h3>Turbine B Run-up</h3>
<ul>
<li>Call Engineering, click Turning gear, and disengage Turbine B. </li>
<li>At the Turbine Panel enable the Synchroscope for Turbine B.</li>
<li>Reduce Turbine B bypass valve to around <strong>20-30%</strong> at the Turbine Panel.</li>
<li>Slowly increase the Turbine Valve to around <strong>60-70%</strong></li>
<li>The RPM should start rising, it should add 30 to the RPM every time it updates.</li>
<li>Open the Grid Sync cap.</li>
<li>Once the RPM reaches above +1770 RPM the Synchroscope will flash and make an audible sound when the needle
passes over the red zone at the top of the gauge.</li>
<li>Once the needle slows down and the RPM is around 1800, wait for the green light to light up and then click
Grid Sync.</li>
<li>If you synced it correctly the RPM will stabilize at 1800.</li>
</ul>
<br>
<h3>If sync is unsuccessful</h3>
<br>
<ul>
<li>Click the Acknowledge button, the corresponding one to silence the Turbine Trip Alarm will be glowing.</li>
<li>Wait for the RPM to drop below 600.</li>
<li>Click the reset button next to the Acknowledge button you just pressed.</li>
<li>Retry the Turbine Sync Process.</li>
</ul>
<br>
<h3>If sync is successful</h3>
<br>
<ul>
<li>Acknowledge the Reverse Power alert.</li>
<li>Increase the Turbine Valve <strong>SLOWLY</strong> to 100%.</li>
<li>Decrease the Bypass valve to 0%.</li>
<li>Once the generator load is positive, click the Reset button next to the Acknowledge button.</li>
<li>Enable Feedwater Pump 2 to speed 2.</li>
<li>Enable Condensate Pump 2 to speed 2.</li>
</ul>
<br>
<h2>Stage Four Startup</h2>
<ul>
<li>Type into the Auto Control Rods keypad <strong>4000</strong> MW.</li>
<li>Set Main Circulation Pumps B1 and B2 to speed 3.</li>
<li>Enable Condenser Coolant Pumps A3 and B3.</li>
<li>Call the Grid Controller and click Go Online.</li>
<li>Enables Bypass valves A and B.</li>
<li>Enable Auto Bypass Valves A and B.</li>
</ul>
<br>
<h2>Reactor Variability</h2>
<h3>Low Power Range [4000MW - 4200MW]</h3>
<ul>
<li>Enable Main Circulation Pumps C1 and C2.</li>
</ul>
<br>
<h3>Medium Power Range [4200MW - 4500MW]</h3>
<ul>
<li>Enable Main Circulation Pumps C1 and C2 and set to speed 2.</li>
<li>Set Condenser Coolant Pumps A3 and B3 to speed 2.</li>
<li>Set Condensate 1 and Feedwater 1 to speed 3</li>
</ul>
<br>
<h3>High Power Range [4500MW - 4800MW]</h3>
<ul>
<li>Enable Main Circulation Pumps C1 and C2 and set to speed 3.</li>
<li>Set Condenser Coolant Pumps A3 and B3 to speed 3.</li>
</ul>
<br>
<h2 class="section-title">Auto Bypass</h2>
<ul class="info-list">
<p>The formula for what to input into each auto-bypass <span class="g"><strong>with</strong></span> extra
efficiency is:</p>
<div class="math-display">
\( \frac{\text{Demand}}{2} + 12 = \text{...} \)
</div>
<p>The formula for what to input into each auto-bypass <span class="r"><strong>without</strong></span> extra
efficiency is:</p>
<div class="math-display">
\( \frac{\text{Demand}}{2} = \text{...} \)
</div>
Here's a basic calculator to help you figure this out!
</ul>
<div class="calculator">
<label for="demandSlider">Demand:</label>
<input type="range" id="demandSlider" name="demandSlider" min="950" max="1500" step="10" value="1000"
oninput="runCalculationTurbine()">
<span id="demandValue">950 MW</span>
<br>
<h3>AutoBalance MW: <span class="inline-codeblock" id="calculation-span">—</span></h3>
<h3>AutoBalance MW (+12): <span class="inline-codeblock" id="calculation-span2">—</span></h3>
</div>
<br>
<br>
<p class="r">The Deaerator significantly contributes to the amount of steam the reactor can produce;
adjust the inlet and relief valves accordingly.</p>
</section>
</main>
<footer>
<p>© 2025 Koyot Digital</p> Our Discord Server, <a href="https://discord.gg/RT3Y6egQhR"><i
class="fa-brands fa-discord"> Koyot Digital</i></a> <br> Play on <a
href="https://www.roblox.com/games/15684145480/Oakridge-Nuclear-Power-Station-V0-2-4-BETA" target="_blank"
rel="noopener"><i>Roblox</i></a>
</footer>
<script src="js/calc.js"></script>
<script src="js/script.js" defer></script>
</body>
</html>