Pallet Pattern Editor

Web-based pallet pattern editor that communicates with a SIMATIC S7 PLC (or PLCSIM Advanced) at 192.168.0.10 via the SIMATIC S7 WebServer API.

PLC / PLCSIM-Advanced Setup

Before running the editor, ensure your PLC or PLCSIM Advanced instance is configured correctly:

  1. Reachability: The PLC must be reachable at 192.168.0.10 from your development machine. Verify with:

    ping 192.168.0.10
  2. Web Server: In TIA Portal, enable the Web Server and Web API for the PLC project:

    • Open the PLC device properties
    • Enable "Web server" and "Web API" features
  3. User Credentials: Create a user (e.g. Admin / 12345678) in the PLC web server configuration. The app uses these defaults; change them in src/services/auth.services.ts if needed.

  4. Browser Access: Open https://192.168.0.10 in a browser and accept the self-signed certificate. This helps avoid TLS warnings when the editor connects.

  5. Data Block: The PLC program must define a data block DB_WebPalletEditor with the structure expected by the editor (header, boxes array, command flags). See src/services/pallet-editor.services.ts for the PLC path mappings.

Development

npm install
npm run dev

The app runs at http://localhost:5173. In development, a Vite proxy forwards /api requests to the PLC to avoid CORS. Set VITE_PLC_TARGET to a different IP if needed:

VITE_PLC_TARGET=192.168.8.10 npm run dev

Build and Deploy

npm run build

Output goes to dist/palletEditor/. Deploy this folder to your PLC web server or any static host.

Manual Testing with PLCSIM-Advanced

  1. Start PLCSIM Advanced and load your TIA Portal project.
  2. Run the PLC (ensure DB_WebPalletEditor is present and the Web API is enabled).
  3. Run npm run dev and open http://localhost:5173.
  4. Connect: The status bar should show "Connected" after login.
  5. Load: Click "Load" to read the current pattern from the PLC.
  6. Edit: Move, rotate, add, or delete boxes. Status shows "Unsaved".
  7. Save: Click "Save" to write the pattern to the PLC. Status should show "Saved".
  8. Error cases: Stop the PLC or use a wrong IP to verify error messages appear in the status line.