This component has been created to be used with Home Assistant.
The Luxtronik integration lets you control heat pump units controlled by a Luxtronik controller. It is used by various manufacturers such as:
- Alpha Innotec
- Siemens Novelan
- Roth
- Elco
- Buderus
- Nibe
- Wolf Heiztechnik
Its only necessary to connect the Luxtronik controller to your network, no additional hard- or software is needed.
To enable this component, add the following lines to your configuration.yaml file:
# Example configuration.yaml entry
luxtronik:
host: 192.168.178.10
port: 8889- host
- description: IP address or hostname of the Luxtronik controller.
- required: true
- type: string
- port
- description: The port name of the Luxtronik controller.
- required: true
- default: 8889
- type: integer
- safe
- description: Enables the writing of unknown parameters if set to false.
- required: false
- default: true
- type: boolean
- lock_timeout
- description: Lock timeout for concurrent read- and write operations in seconds.
- required: false
- default: 30
- type: integer
- update_immediately_after_write
- description: Update sensor data after every write operation
- required: false
- default: false
- type: boolean
Note:
Not all data received by the Luxronik controller is understood by now as the protocol is not publicly documented.
Take these files as a reference to figure ot which IDs to use:
- https://github.com/Bouni/python-luxtronik/blob/master/luxtronik/parameters.py
- https://github.com/Bouni/python-luxtronik/blob/master/luxtronik/calculations.py
- https://github.com/Bouni/python-luxtronik/blob/master/luxtronik/visibilities.py
In order to change parameters on the Luxtronik conroller, you can use the following service:
Domain: luxtronik
Service: write
Service Data: {"parameter": "ID_Ba_Hz_akt", "value": "Automatic"}- parameter
- description: ID of the parameter.
- type: string
- value
- description: Value you want to set the parameter to.
- type: [string, float]
Only a small number of the over 1100 parameters have a known funtion and only these can be written, these are:
ID_Ba_Hz_aktThe mode of operation of the heating circuit, possible values are "Automatic", "Second heatsource", "Party", "Holidays", "Off"ID_Ba_Bw_aktThe mode of operation of the hot water circuit, possible valus are "Automatic", "Second heatsource", "Party", "Holidays", "Off"ID_Soll_BWS_aktThe set point for hot water generation, for example 50.0 for 50.0°CID_Einst_BA_Kuehl_aktThe mode of operation of the cooling circuit, possible values are "Automatic", "Off"ID_Einst_KuehlFreig_aktThe outdoor temprature from wher on the cooling should start to operate, for example 24.0ID_Ba_Sw_aktThe mode of operation of the swimming pool heating circuit, possible values are "Automatic", "Party", "Holidays", "Off"ID_Einst_TDC_Max_aktMax. temperature difference of the hot water buffer tank, for example 70.0ID_Sollwert_KuCft1_aktCooling set point for mixer circuit 1, for example 19.0ID_Sollwert_KuCft2_aktCooling set point for mixer circuit 2, for example 19.0ID_Sollwert_AtDif1_aktCooling working temperature difference 1, for example 5.0ID_Sollwert_AtDif2_aktCooling working temperature difference 2, for example 5.0ID_Ba_Hz_MK3_aktThe mode of operation of the heating mixer circuit 3, possible values are "Automatic", "Party", "Holidays", "Off"ID_Einst_Kuhl_Zeit_Ein_aktCooling outdoor temperature overrun, for example 0.0ID_Einst_Kuhl_Zeit_Aus_aktCooling outdoor temperature underrun, for example 0.0ID_Einst_Solar_aktMode of operation for solar heat generation, "Automatic", "Second heatsource", "Party", "Holidays", "Off"ID_Einst_BA_Lueftung_aktMode of operation of the integrated ventilation unit, posisble values are "Automatic", "Party", "Holidays", "Off"ID_Sollwert_KuCft3_aktCooling set point for mixer circuit 3, for example 20.0ID_Sollwert_AtDif3_aktCooling working temperature difference 3, for example 5.0
Note:
Before changing a parameter it smart to first read the current value and note it somewhere in case you want to set it back to its original value.
All parameters can be configured as sensors and read that way.
If you want to write unknown parameters, set the config option safe to false.
The Luxtronik sensor platform allows you to monitor the status values of a heat pump unit controlled by a Luxtronik controller.
Sensors are read-only. To write to the heatpump, use the provided service Luxtronik Integration - Service.
To use a Luxtronik sensor in your installation, add the following lines to your configuration.yaml file:
# Example configuration.yaml entry
sensor:
- platform: luxtronik
sensors:
- group: calculations
id: ID_WEB_Temperatur_TVL- group:
- description: Value group where the ID is located, possible values are
calculations,parameters,visibilities. - required: true
- type: string
- description: Value group where the ID is located, possible values are
- id:
- description: The id of the value.
- required: true
- type: string
- friendly_name:
- description: Sets a meaningful name for the sensor, if not provided the sensor will be named after the id,
luxtronik.id_webemperatur_tvlfor example, otherwiseluxtronik.temperature_forerun. - required: false
- type: string
- description: Sets a meaningful name for the sensor, if not provided the sensor will be named after the id,
- icon:
- description: Set an icon for the sensor
- required: false
- type: string
# Example configuration.yaml entry
sensor:
- platform: luxtronik
sensors:
- group: calculations
id: ID_WEB_Temperatur_TVL
friendly_name: Temperature forerun
icon: mdi:thermometerThe Luxtronik binary sensor platform allows you to monitor the status values of a heat pump unit controlled by a Luxtronik controller.
Binary sensors are read-only. To write to the heatpump, use the provided service Luxtronik Integration - Service.
To use a Luxtronik binary sensor in your installation, add the following lines to your configuration.yaml file:
# Example configuration.yaml entry
binary_sensor:
- platform: luxtronik
sensors:
- group: calculations
id: ID_WEB_EVUin- group:
- description: Value group where the ID is located, possible values are
calculations,parameters,visibilities. - required: true
- type: string
- description: Value group where the ID is located, possible values are
- id:
- description: The id of the value.
- required: true
- type: string
- friendly_name:
- description: Sets a meaningful name for the sensor, if not provided the sensor will be named after the id,
luxtronik.id_web_evuinfor example, otherwiseluxtronik.utility_company_lock. - required: false
- type: string
- description: Sets a meaningful name for the sensor, if not provided the sensor will be named after the id,
- icon:
- description: Set an icon for the sensor
- required: false
- type: string
- invert:
- description: Inverts the value
- required: false
- type: boolean
- default: false
# Example configuration.yaml entry
binary_sensor:
- platform: luxtronik
sensors:
- group: calculations
id: ID_WEB_EVUin
friendly_name: Utility company lock
icon: mdi:lock