This repository contains the complete technical blueprints, deployment manifests, and automation scripts used to validate the integration of Cisco ACI VMM-Lite (Chained Mode) with Red Hat OpenShift. The test has been perfomed in an environment running OpenShift version 4.20 and uses the ACI Simulator 6.0 available at Cisco DevNet.
In traditional enterprise data centers, network infrastructure management is often centralized within the network security operations team using Cisco ACI Application Policy Infrastructure Controllers (APIC). When migrating workloads from VMware ESXi to Red Hat OpenShift Virtualization, a critical architectural challenge emerges: maintaining seamless, policy-driven network provisioning for Virtual Machines without disrupting existing operational structures or forcing the network team to manage Kubernetes manifests.
Source: https://www.cisco.com/c/en/us/td/docs/dcn/aci/containers/cno/cno-vmmlite-user-guide.html To bridge this operational gap, Cisco developed the Cisco Network Operator (CNO) VMM-Lite functionality. This specialized operator provides a non-intrusive, infrastructure-led integration model known as Chained Mode or Secondary CNI.
This tool was designed precisely for clients migrating from VMware + ACI VMM environments who want to maintain their exact current infrastructure workflows. Unlike a full CNI replacement where Cisco ACI replaces the entire default Kubernetes networking stack, VMM-Lite leaves the primary cluster network engine completely untouched:
- Primary Network Control Plane: Red Hat OpenShift retains its native, highly optimized OVN-Kubernetes CNI to handle all internal cluster networking, master-to-worker core communications, service load balancing, and secure ingress routing.
- Secondary Network Data Plane: Cisco CNO VMM-Lite acts as a specialized automation clerk. It opens a secure, persistent WebSocket channel to the Cisco APIC APIs, monitors for specific hardware policy mutations (specifically EPGs and AAEPs assigned to the OpenShift nodes), and leverages Multus CNI to dynamically provision Layer 2 networks via Network Attachment Definitions (NAD) exclusively for external attachments like Virtual Machines.
- Preservation of Operational Boundaries: The network infrastructure team continues to orchestrate networks, VLAN allocation, security domains, and endpoint groups centrally from the ACI APIC GUI or API pipelines, replicating almost 100% of the VMware operational experience.
- Dynamic Policy Reconciliation: When an engineer provisions or amends an Endpoint Group (EPG) in ACI and tags it with a target Kubernetes metadata namespace annotation, the CNO operator intercepts the event and automatically translates it into a local Kubernetes NetworkAttachmentDefinition (NAD) object.
- Zero Cluster Control Plane Intrusion: Because the core cluster nodes communicate over native OVN-Kubernetes paths, any infrastructure modification or firmware update on the Cisco ACI fabric cannot destabilize core Kubernetes cluster operations.
The integration architecture relies on four main software and hardware definition layers to bind the physical network fabric to the OpenShift virtualization runtime:
- Cisco Network Operator (CNO) VMM-Lite: The central controller deployed inside the
aci-containers-systemnamespace. It authenticates against the APIC controller via signature-based cryptographic keys and coordinates configuration tracking. - Multus CNI Engine: The standard Kubernetes Multi-Network plugin that allows individual Pods and Virtual Machine instances to attach to multiple isolated hardware network interfaces simultaneously.
AaepMonitorCustom Resource: A dedicated cluster-wide singleton object utilized by the CNO operator to discover and monitor the explicit physical Attachable Access Entity Profiles (AAEP) matching the physical network switch cables plugged into the back of the bare-metal servers.- Host Linux Bridge (
br-nad): A declarative, kernel-level software bridge deployed across the operating system layer of the OpenShift worker nodes via the Kubernetes NMState Operator, functioning as a physical or virtual trunk interface to pass Layer 2 frames.
To validate this architecture end-to-end within a virtualized demonstration or pipeline environment (such as a Single Node OpenShift (SNO) instance) without requiring a physical switch fabric, the deployment leverages a Cisco DevNet Sandbox running ACI Simulator 6.0. The standard "Always-On" sandbox model cannot be used because it is read-only and prevents object creation.
Because an SNO instance hosted in a virtual cloud platform lacks secondary physical network adapters physically wired to real Cisco Nexus hardware, a dedicated cloud-native proxy bridge pod must be deployed to simulate control plane reachability.
Execute the following manifests to provision the dedicated cisco-vpn namespace, instantiate a secure DTLS tunnel using openconnect, and map automated port forwarding via socat to safely expose the APIC API endpoints inside the cluster host network space.
Save as cisco-vpn-setup.yaml and apply to the cluster:
apiVersion: v1
kind: Namespace
metadata:
name: cisco-vpn
spec: {}
---
apiVersion: v1
kind: Secret
metadata:
name: cisco-vpn-connection
namespace: cisco-vpn
type: Opaque
stringData:
server: "<<< VPN_SERVER >>>" # ==> REPLACE with the provided by Cisco DevNet Sandbox (email)
user: "<<< VPN_USER >>>" # ==> REPLACE with your sandbox VPN username
password: "<<< VPN_PASSWORD >>>" # ==> REPLACE with your sandbox VPN credentials
---
apiVersion: v1
kind: Secret
metadata:
name: cisco-apic-connection
namespace: cisco-vpn
type: Opaque
stringData:
server: "<<< APIC_SERVER >>>" # ==> REPLACE with the provided by Cisco DevNet Sandbox (APIC)
user: "<<< APIC_USER >>>" # ==> REPLACE with your sandbox APIC username
password: "<<< APIC_PASSWORD >>>" # ==> REPLACE with your sandbox APIC credentialsSave as cisco-vpn-bridge-pod.yaml and apply:
apiVersion: v1
kind: Pod
metadata:
name: cisco-vpn-bridge
namespace: cisco-vpn
spec:
hostNetwork: true
containers:
- name: vpn-client
image: fedora:latest
securityContext:
privileged: true
env:
- name: VPN_SERVER
valueFrom:
secretKeyRef:
name: cisco-vpn-connection
key: server
- name: VPN_USER
valueFrom:
secretKeyRef:
name: cisco-vpn-connection
key: user
- name: VPN_PASSWORD
valueFrom:
secretKeyRef:
name: cisco-vpn-connection
key: password
- name: APIC_SERVER
valueFrom:
secretKeyRef:
name: cisco-apic-connection
key: server
command:
- /bin/sh
- -c
args:
- |
# 1. Update package managers and provision system utilities
dnf install -y openconnect net-tools iproute socat
echo "Launching automated Port-Forwarding bridge via socat..."
# 2. Bind background socat to translate local cluster port 8443 to APIC SSL 443
socat TCP6-LISTEN:8443,fork,reuseaddr TCP:${APIC_SERVER}:443 &
echo "Starting automated Cisco VPN connection..."
# 3. Initialize openconnect in the foreground to persist the pod runtime lifecycle
echo "$VPN_PASSWORD" | openconnect "$VPN_SERVER" \
--user="$VPN_USER" \
--authgroup="SSLClient" \
--passwd-on-stdin \
--non-interTo safely audit the APIC configuration panel from a local engineering station, bridge the cluster proxy pod to your machine using the OpenShift CLI port-forward mechanism:
oc port-forward cisco-vpn-bridge 8443:8443 -n cisco-vpnOpen a local web browser and navigate to https://localhost:8443. You can now authenticate using the assigned administrative sandbox credentials. You will see the main APIC login screen:
Before the Cisco CNO operator can securely link a discovered fabric VLAN to a local Virtual Machine interface, a matching kernel bridge interface must exist across the target cluster node operating systems. In Red Hat OpenShift, host-level network engineering is managed declaratively via the Kubernetes NMState Operator.
By omitting the physical port definition block within the NMState policy manifest, the host engine safely initializes a fully functional virtual software bridge interface named br-nad. This allows Multus bindings and container interfaces to attach and pass local traffic within memory without risking network disruption or cutting off host cloud connectivity.
Save as nmstate-operator.yaml and apply to initialize the engine components:
apiVersion: v1
kind: Namespace
metadata:
name: openshift-nmstate
finalizers:
- kubernetes
---
apiVersion: operators.coreos.com/v1
kind: OperatorGroup
metadata:
name: openshift-nmstate
namespace: openshift-nmstate
spec:
targetNamespaces:
- openshift-nmstate
---
apiVersion: operators.coreos.com/v1alpha1
kind: Subscription
metadata:
name: kubernetes-nmstate-operator
namespace: openshift-nmstate
spec:
channel: stable
installPlanApproval: Automatic
name: kubernetes-nmstate-operator
source: redhat-operators
sourceNamespace: openshift-marketplaceSave as nmstate-singleton.yaml and apply to distribute the host configuration daemons:
apiVersion: nmstate.io/v1
kind: NMState
metadata:
name: nmstateSave as nmstate-bridge-policy.yaml and apply:
apiVersion: nmstate.io/v1
kind: NodeNetworkConfigurationPolicy
metadata:
name: br-nad-bridge-policy
spec:
nodeSelector:
kubernetes.io/os: linux
desiredState:
interfaces:
- name: br-nad
type: linux-bridge
state: up
bridge:
options:
stp:
enabled: falseVerify that the policy states have compiled successfully by executing:
oc get nncp br-nad-bridge-policyExpected Status Outcome:
SuccessfullyConfigured
The generation of the VMM-Lite controller manifests is driven by Cisco's specialized deployment utility, acc-provision. This CLI tool processes a centralized infrastructure parameters file to compile the entire target Kubernetes resource bundle. We need first to install the tool:
pip install acc-provisionCreate the input configuration layout. Note that the kubeapi_vlan field is intentionally omitted from this definition file. In a VMM-Lite Chained Mode deployment, kubeapi_vlan is a legacy flag; because the primary host network is independently orchestrated by OVN-Kubernetes, the CNO operator completely ignores it.
aci_config:
apic_hosts:
- X.X.X.X # ==> REPLACE with the IP given by the Cisco sandbox for the admin user.
vmm_lite_config:
aaep_monitoring_enabled: True
bridge_name: "br-nad"
cno_identifier: "cno-id1"
bridge_nad_config_file: "bridge_cni_config.yaml"
apic_username: "admin"Create the secondary network attachment rules mapping file.
Note on hairpinMode: false: The hairpinMode flag dictates whether a Linux bridge interface allows a packet to pull an immediate 180-degree U-turn and return through the exact same virtual port it originated from. While this capability is mandatory for primary container service layers, it is set to false for the secondary Cisco network. This maintains standard, secure, loop-free switching behavior for dedicated Virtual Machines.
isGateway: false
isDefaultGateway: false
forceAddress: false
mtu: 1500
ipMasq: false
hairpinMode: false
promiscMode: false
enabledad: false
disableContainerInterface: false
portIsolation: false
ipam:
type: host-local
subnet: 10.1.1.0/24When executing the compilation script with automated fabric injection commands:
export PASSWORD="<<< APIC_PASSWORD >>>" # ==> REPLACE <<< APIC_PASSWORD >>> with the admin password provided by the ACI Simulator 6.0.
acc-provision -a \
-c acc-provision-input.yaml \
-f openshift-vmm-lite-baremetal \
-u admin \
-p $PASSWORD \
-o aci_deployment_vmm_lite.yamlThe routine may complete manifest generation but fail to communicate with the simulator fabric, throwing the following exception:
ERR: Max retries reached for POST request to /api/node/mo/uni/userext/user-admin.json.
ERR: Error in provisioning: APIC REST Error: {'attributes': {'code': '107', 'text': 'User admin privileges cannot be changed'}}
This failure occurs because public sandbox environments explicitly implement read-only security gates across local user privilege structures. The script is blocked from programmatically uploading the runtime authentication certificates to the root admin account profile.
To bypass this limitation and establish authenticated WebSocket tunnels, the operator public key certificate must be injected manually via the APIC console interface:
- Locate the public certificate file (
user-admin.crt) generated locally on your file system by the tool execution pass. Open it with a text editor and copy the entire string block. - Log into the APIC console at
https://localhost:8443. - From the primary menu array, select Admin ➔ AAA ➔ Users and then the Local tab.
- Click on the user profile row designated for
admin. - Within the dropdown on the right side of the window, click on Edit and then in Advanced Settings and finally on Add X509 Certificate.
- Click the + (Add) button:
- Name:
user-admin - Certificate Data: Paste the public key block exactly as copied.
- Name:
- Click Submit.
In production corporate fabrics, altering the core administrative user is strictly prohibited. Infrastructure teams deploy a dedicated, long-lived automation account using explicit cryptographic signature keys. Instead of generating random credentials, you map the acc-provision-input.yaml manifest to a pre-existing 10-year certificate pair via the sync_login block:
aci_config:
apic_hosts:
- X.X.X.X # ==> REPLACE with the IP given by the Cisco sandbox for the admin user.
sync_login:
username: "openshift-operator-svc"
certfile: "/usr/local/etc/aci-cert/production-user.crt"
keyfile: "/usr/local/etc/aci-cert/production-user.key"Once the finalized deployment manifest is generated, push the structural operator configurations to the cluster:
oc apply -f aci_deployment_vmm_lite.yamlExpect the operator pods are up and running:
To bind the cluster monitoring daemons to the virtual hardware interfaces, create the AaepMonitor object. This ensures the operator tracks the relevant physical advancement profiles (e.g., Heroes_phys and SnV_phys profiles). For instance, in the simulation environment we have:
We can create then the Monitoring object, which tells the operator the profiles to observe:
apiVersion: aci.attachmentmonitor/v1
kind: AaepMonitor
metadata:
name: aaepmonitor
namespace: aci-containers-system
spec:
aaeps:
- Heroes_phys
- SnV_physLog into the APIC console interface, navigate to your active Tenant workspace, select an Application EPG (such as vm-integration-vlan120), and navigate to the Static AAEP folder mapping. Select your targeted physical profile domain (Heroes_phys) and bind an initial VLAN ID tag (e.g., 131).
To trigger the automation sync, annotate the EPG object metadata property (observe the prefix cno-id1. It has been set up in the acc-provision-input.yaml file in the key .vmm_lite_config.cno_identifier:
NOTE: Namespace
cisco-integration-vlan120must be created to see the NAD.
- Key:
cno-id1-namespace - Value:
cisco-integration-vlan120
Execute the following search query within the target namespace to confirm that the CNO operator successfully processed the WebSocket frame and auto-generated the matching Multus configuration:
oc get network-attachment-definitions -n cisco-integration-vlan120To audit the underlying JSON config structure and verify that the VLAN ID has been injected cleanly, run:
oc get network-attachment-definition -n cisco-integration-vlan120 -o jsonpath='{.items[0].spec.config}' | jqAs an example
Return to the APIC interface panel, modify the active Encap and Primary Encap VLAN parameters, shifting the tag from value 131 down to 120, and click Submit.
Re-execute the OpenShift JSON inspection utility. The CNO operator will automatically update the target object parameters in place without needing a restart or manual intervention:
oc get network-attachment-definition -n cisco-integration-vlan120 -o jsonpath='{.items[0].spec.config}' | jq .vlanOutput Result:
120
Delete the Application EPG from the Cisco APIC console tree. Run an administrative query against the OpenShift cluster namespace:
oc get network-attachment-definitions -n cisco-integration-vlan120Expected Final Outcome:
No resources found.
This confirms that the automated network lifecycle cleanup is working perfectly and the integration is ready for production use.