- Code is fully migrated to .NET 8, thus, Mono dependency is obsolete
- Added an action for automatic building and testing on all code changes
- Added an action to produce self-contained and framework-based binaries for all major platforms on release
- Parquet format is updated to version 0.2
- Charge state array can be included in mzML and MGF output
- Precursor ion intensity in MGF output
- Support for precursor ion and neutral/loss gain scans
- Cleaner error messaging and improved error handling