201 changes: 160 additions & 41 deletions src/devices/tuya.ts
Original file line number Diff line number Diff line change
Expand Up @@ -10401,69 +10401,85 @@ export const definitions: DefinitionWithExtend[] = [
tuya.whitelabel("Haozee", "HT-SP-ZB-01", "Smart plug (with power monitoring)", ["_TZ3210_w0qqde0g"]),
],
ota: true,
extend: [
tuya.modernExtend.tuyaBase(),
tuya.modernExtend.tuyaOnOff({
electricalMeasurements: true,
electricalMeasurementsFzConverter: tuya.fz.TS011F_electrical_measurement,

// Conditional features
powerOutageMemory: (manufacturerName) => manufacturerName !== "_TZ3000_cicwjqth",
indicatorMode: (manufacturerName) => manufacturerName !== "_TZ3000_ww6drja5",
childLock: (manufacturerName) => manufacturerName !== "_TZ3000_cicwjqth",
onOffCountdown: (manufacturerName) => manufacturerName !== "_TZ3000_cicwjqth",
switchTypeButton: true,
}),
m.identify(),
extend: [tuya.modernExtend.tuyaBase(), m.identify(), m.electricityMeter()],
fromZigbee: [
fz.on_off,
tuya.fz.on_off_countdown,
tuya.fz.power_outage_memory,
tuya.fz.child_lock,
tuya.fz.indicator_mode,
tuya.fz.switch_type_button,
],
toZigbee: [
tz.on_off,
tuya.tz.on_off_countdown,
tuya.tz.power_on_behavior_1,
tuya.tz.child_lock,
tuya.tz.backlight_indicator_mode_1,
tuya.tz.switch_type_button,
],
// Dynamic multi-gang: first endpoint stays as unsuffixed "state"; the rest become CH<ID>.
// A single function controls ordering: state -> CH2..CHN -> features.
exposes: (device) => {
const eps = !utils.isDummyDevice(device) ? device.endpoints.filter((ep) => ep.supportsInputCluster("genOnOff")) : [];
const mfr = device?.manufacturerName;
const feats = [];
feats.push(e.switch()); // first endpoint = state
for (const ep of eps.slice(1)) feats.push(e.switch().withEndpoint(`CH${ep.ID}`)); // CH2..CHN
// Features (mirrors the vendor-specific conditions of the original plug_1)
if (mfr !== "_TZ3000_cicwjqth") {
feats.push(tuya.exposes.countdown().withAccess(ea.ALL)); // first endpoint -> countdown
for (const ep of eps.slice(1)) feats.push(tuya.exposes.countdown().withAccess(ea.ALL).withEndpoint(`CH${ep.ID}`)); // CH2..CHN -> countdown_CHn
}
if (mfr !== "_TZ3000_cicwjqth") feats.push(tuya.exposes.powerOutageMemory());
if (mfr !== "_TZ3000_ww6drja5") feats.push(tuya.exposes.indicatorMode());
if (mfr !== "_TZ3000_cicwjqth") feats.push(e.child_lock());
feats.push(tuya.exposes.switchTypeButton());
return feats;
},
endpoint: (device) => {
const map: {[s: string]: number} = {};
const eps = device?.endpoints ? device.endpoints.filter((ep) => ep.supportsInputCluster("genOnOff")) : [];
for (const ep of eps.slice(1)) map[`CH${ep.ID}`] = ep.ID;
return map;
},
meta: {
multiEndpoint: true,
// Device-level attributes must not get an endpoint suffix.
// Do NOT list "state" here: multi-gang switching relies on "state" being suffixed per endpoint.
multiEndpointSkip: ["power", "current", "voltage", "energy", "child_lock", "power_outage_memory", "indicator_mode", "switch_type"],
},
configure: async (device, coordinatorEndpoint) => {
await tuya.configureMagicPacket(device, coordinatorEndpoint);
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ["genOnOff", "haElectricalMeasurement", "seMetering"]);

if (!["_TZ3000_okaz9tjs"].includes(device.manufacturerName)) {
// https://github.com/Koenkk/zigbee2mqtt/issues/29034
await reporting.currentSummDelivered(endpoint);
await reporting.rmsVoltage(endpoint, {change: 5});
await reporting.rmsCurrent(endpoint, {change: 50});
}

if (
!["_TZ3000_0zfrhq4i", "_TZ3000_okaz9tjs", "_TZ3000_typdpbpg", "_TZ3000_ww6drja5", "Zbeacon", "_TZ3000_cicwjqth"].includes(
device.manufacturerName,
)
) {
// Gives INVALID_DATA_TYPE error for _TZ3000_0zfrhq4i (as well as a few others in issue 20028)
// Gives INVALID_DATA_TYPE for _TZ3000_0zfrhq4i and a few others (issue 20028).
// https://github.com/Koenkk/zigbee2mqtt/discussions/19680#discussioncomment-7667035
// Don't do this for `_TZ3000_gjnozsaz` (was previously in the list, but removed after:
// https://github.com/Koenkk/zigbee2mqtt/issues/28729#issuecomment-3370261334
// Excludes _TZ3000_gjnozsaz per https://github.com/Koenkk/zigbee2mqtt/issues/28729#issuecomment-3370261334
await reporting.activePower(endpoint, {change: 10});
}

const acCurrentDivisor = ["_TZ3000_typdpbpg"].includes(device.manufacturerName) ? 2000 : 1000;
// Fallback scaling factors, used only when the device does not report its own
// multipliers/divisors. m.electricityMeter() reads them from the device and,
// when successful, overrides the values saved here.
endpoint.saveClusterAttributeKeyValue("haElectricalMeasurement", {
acCurrentDivisor,
acVoltageMultiplier: 1,
acVoltageDivisor: 1,
acPowerMultiplier: 1,
acPowerDivisor: 1,
acCurrentDivisor: 1000,
acCurrentMultiplier: 1,
});
// Some TS011F plugs (e.g. _TZ3008_reatplte) report voltage/power/current scaled by a non-default
// factor and expose the correct multipliers/divisors via the haElectricalMeasurement cluster.
// Try to read each attribute individually because some devices return UNSUPPORTED_ATTRIBUTE for a
// subset, and reading them in bulk would cause one failure to abort the rest. Successful reads are
// cached by zigbee-herdsman and override the hardcoded values saved above.
for (const attr of [
"acVoltageMultiplier",
"acVoltageDivisor",
"acPowerMultiplier",
"acPowerDivisor",
"acCurrentMultiplier",
"acCurrentDivisor",
] as const) {
try {
await endpoint.read("haElectricalMeasurement", [attr]);
} catch {
/* Not all Tuya plugs expose all multiplier/divisor attributes; fall back to defaults. */
}
}
endpoint.saveClusterAttributeKeyValue("seMetering", {
divisor: 100,
multiplier: 1,
Expand Down Expand Up @@ -10513,6 +10529,109 @@ export const definitions: DefinitionWithExtend[] = [
description: "Gas sensor",
extend: [m.iasZoneAlarm({zoneType: "gas", zoneAttributes: ["alarm_1", "alarm_2", "tamper", "battery_low"]})],
},
{
fingerprint: [
{modelID: "TS011F", manufacturerName: "_TZ3000_tary5dvv"},
{modelID: "TS011F", manufacturerName: "_TZ3210_iooniers"},
{modelID: "TS011F", manufacturerName: "_TZ3000_xvfd3nkp"},
{modelID: "TS011F", manufacturerName: "_TZ3000_qziabvzj"},
],
model: "TS011F_Socket",
description: "Smart plug (with power monitoring)",
vendor: "Tuya",
whiteLabel: [
tuya.whitelabel("EIGHTREE", "EIGHTREE Socket", "EIGHTREE ZigBee socket based on Tuya", [
"_TZ3000_tary5dvv",
"_TZ3210_iooniers",
"_TZ3000_xvfd3nkp",
"_TZ3000_qziabvzj",
]),
],
ota: true,
extend: [tuya.modernExtend.tuyaBase(), m.identify(), m.electricityMeter()],
fromZigbee: [
fz.on_off,
tuya.fz.on_off_countdown,
tuya.fz.power_outage_memory,
tuya.fz.child_lock,
tuya.fz.indicator_mode,
tuya.fz.switch_type_button,
],
toZigbee: [
tz.on_off,
tuya.tz.on_off_countdown,
tuya.tz.power_on_behavior_1,
tuya.tz.child_lock,
tuya.tz.backlight_indicator_mode_1,
tuya.tz.switch_type_button,
],
// Dynamic multi-gang: first endpoint stays as unsuffixed "state"; the rest become CH<ID>.
// A single function controls ordering: state -> CH2..CHN -> features.
exposes: (device) => {
const eps = !utils.isDummyDevice(device) ? device.endpoints.filter((ep) => ep.supportsInputCluster("genOnOff")) : [];
const _mfr = device?.manufacturerName;
const feats = [];
feats.push(e.switch()); // first endpoint = state
for (const ep of eps.slice(1)) feats.push(e.switch().withEndpoint(`CH${ep.ID}`)); // CH2..CHN
// Features (mirrors the vendor-specific conditions of the original plug_1)
feats.push(tuya.exposes.countdown().withAccess(ea.ALL)); // first endpoint -> countdown
for (const ep of eps.slice(1)) feats.push(tuya.exposes.countdown().withAccess(ea.ALL).withEndpoint(`CH${ep.ID}`)); // CH2..CHN -> countdown_CHn

feats.push(tuya.exposes.powerOutageMemory());
feats.push(tuya.exposes.indicatorMode());
feats.push(e.child_lock());
feats.push(tuya.exposes.switchTypeButton());
return feats;
},
endpoint: (device) => {
const map: {[s: string]: number} = {};
const eps = device?.endpoints ? device.endpoints.filter((ep) => ep.supportsInputCluster("genOnOff")) : [];
for (const ep of eps.slice(1)) map[`CH${ep.ID}`] = ep.ID;
return map;
},
meta: {
multiEndpoint: true,
// Device-level attributes must not get an endpoint suffix.
// Do NOT list "state" here: multi-gang switching relies on "state" being suffixed per endpoint.
multiEndpointSkip: ["power", "current", "voltage", "energy", "child_lock", "power_outage_memory", "indicator_mode", "switch_type"],
},
configure: async (device, coordinatorEndpoint) => {
await tuya.configureMagicPacket(device, coordinatorEndpoint);
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ["genOnOff", "haElectricalMeasurement", "seMetering"]);
await reporting.currentSummDelivered(endpoint);
await reporting.rmsVoltage(endpoint, {change: 5});
await reporting.rmsCurrent(endpoint, {change: 50});

if (
!["_TZ3000_0zfrhq4i", "_TZ3000_okaz9tjs", "_TZ3000_typdpbpg", "_TZ3000_ww6drja5", "Zbeacon", "_TZ3000_cicwjqth"].includes(
device.manufacturerName,
)
) {
// Gives INVALID_DATA_TYPE for _TZ3000_0zfrhq4i and a few others (issue 20028).
// https://github.com/Koenkk/zigbee2mqtt/discussions/19680#discussioncomment-7667035
// Excludes _TZ3000_gjnozsaz per https://github.com/Koenkk/zigbee2mqtt/issues/28729#issuecomment-3370261334
await reporting.activePower(endpoint, {change: 10});
}
// Fallback scaling factors, used only when the device does not report its own
// multipliers/divisors. m.electricityMeter() reads them from the device and,
// when successful, overrides the values saved here.
endpoint.saveClusterAttributeKeyValue("haElectricalMeasurement", {
acVoltageMultiplier: 1,
acVoltageDivisor: 1,
acPowerMultiplier: 1,
acPowerDivisor: 1,
acCurrentDivisor: 1000,
acCurrentMultiplier: 1,
});
endpoint.saveClusterAttributeKeyValue("seMetering", {
divisor: 100,
multiplier: 1,
});
utils.attachOutputCluster(device, "genOta");
device.save();
},
},
{
fingerprint: [
{modelID: "TS011F", applicationVersion: 192, manufacturerName: "_TZ3000_2uollq9d", priority: -1},
Expand Down
6 changes: 4 additions & 2 deletions test/index.test.ts
Original file line number Diff line number Diff line change
Expand Up @@ -132,6 +132,8 @@ describe("ZHC", () => {
const definition3 = await findByDevice(device3);

expect(definition1.model).toStrictEqual("HG06338");
// TS011F_plug_3 version-only fingerprints have priority:-1, so they still win
// over TS011F_plug_1's zigbeeModel match but lose to priority-0 fingerprints.
expect(definition2.model).toStrictEqual("TS011F_plug_3");
expect(definition3.model).toStrictEqual("TS011F_plug_1");
});
Expand Down Expand Up @@ -498,10 +500,10 @@ describe("ZHC", () => {
expect(ts011fPlug1.options.map((t) => t.name)).toStrictEqual([
"power_calibration",
"power_precision",
"current_calibration",
"current_precision",
"voltage_calibration",
"voltage_precision",
"current_calibration",
"current_precision",
"energy_calibration",
"energy_precision",
"identify_timeout",
Expand Down