FIX: Added 2 seconds to the Shelly timer to prevent short interruptio…
Browse files Browse the repository at this point in the history
…n between two continuous heating hours.
  • Loading branch information
LeivoSepp committed Dec 10, 2024
1 parent daeb6bb commit 8463a16
Showing 1 changed file with 24 additions and 23 deletions.
47 changes: 24 additions & 23 deletions SmartHeatingWidthShelly.js
Original file line number Diff line number Diff line change
Expand Up @@ -59,7 +59,7 @@ let s = {
elektrilevi: "VORK2", // ELEKTRILEVI transmission fee: VORK1 / VORK2 / VORK4 /VORK5 / NONE
alwaysOnLowPrice: 10, // Keep heating always ON if energy price lower than this value (EUR/MWh)
alwaysOffHighPrice: 300, // Keep heating always OFF if energy price higher than this value (EUR/MWh)
isOutputInverted: true, // Configures the relay state to either normal or inverted. (inverted required by Nibe, Thermia)
isOutputInverted: false, // Configures the relay state to either normal or inverted. (inverted required by Nibe, Thermia)
relayID: 0, // Shelly relay ID
defaultTimer: 60, // Default timer duration, in minutes, for toggling the Shelly state.
country: "ee", // Estonia-ee, Finland-fi, Lithuania-lt, Latvia-lv
Expand Down Expand Up @@ -123,7 +123,7 @@ let _ = {
rpcBlock: 1,
schedId: [],
missingParams: [],
version: 3.2,
version: 3.3,
};

/*
Expand Down Expand Up @@ -158,31 +158,33 @@ function checkSettingsKvs() {
Shelly.call('KVS.GetMany', null, processKVSData);
}
function processKVSData(res, err, msg, data) {
let kvsData;
if (res) {
kvsData = res;
kvsData = res.items;
res = null; //to save memory
}
//this old version number is used to maintain backward compatibility
let oldVersionNumber = (kvsData["items"]["version" + _.sId] != null && kvsData["items"]["version" + _.sId].value >= 3.2) ? 3.2 : 0;
let oldVersionNumber = (kvsData["version" + _.sId] != null && kvsData["version" + _.sId].value >= 3.2) ? 3.2 : 0;
let isExistInKvs = false;
//iterate through settings and then iterate through KVS
for (var k in s) {
for (var i in kvsData) {
//check if settings found in KVS
if (kvsData[i][k + _.sId] != null) {
if ([k] == "elektrilevi" || [k] == "country") {
if (oldVersionNumber >= 3.2) {
s[k] = kvsData[i][k + _.sId].value; //do not convert strings
}
else {
break; //store new versions of elektrilevi and country values <- this is for backward compatibility
}
if (i == k + _.sId) {
if (k == "elektrilevi" || k == "country") {
if (oldVersionNumber >= 3.2) {
s[k] = kvsData[i].value; //do not convert strings
}
else {
break; //store new versions of elektrilevi and country values <- this is for backward compatibility
}
}
else {
s[k] = JSON.parse(kvsData[i][k + _.sId].value); //convert string values to object
s[k] = JSON.parse(kvsData[i].value); //convert string values to object
}
isExistInKvs = true;
}
isExistInKvs = true;
break;
}
}
if (isExistInKvs) {
isExistInKvs = false;
Expand All @@ -194,6 +196,7 @@ function processKVSData(res, err, msg, data) {
_.missingParams.push([k, s[k]]);
}
}
kvsData = null; //save memory
//convert the elektrilevi packet value to variable
s.elektrilevi = eval(s.elektrilevi);

Expand Down Expand Up @@ -638,12 +641,11 @@ Set countdown timer to flip Shelly status
*/
function setShellyTimer(isOutInv, timerMin) {
let is_on = isOutInv ? "on" : "off";
let timerSec = timerMin * 60; //time in seconds
let timerSec = timerMin * 60 + 2; //time in seconds, +2sec to remove flap between continous heating hours
print(_.pId, "Set Shelly auto " + is_on + " timer for ", timerMin, " minutes.");
Shelly.call("Switch.SetConfig", {
"id": 0,
id: s.relayID,
config: {
"name": "Switch0",
"auto_on": isOutInv,
"auto_on_delay": timerSec,
"auto_off": !isOutInv,
Expand All @@ -656,9 +658,8 @@ function setShellyTimer(isOutInv, timerMin) {
function setShellyManualMode(reason) {
//remove ShellyTimer
Shelly.call("Switch.SetConfig", {
"id": 0,
id: s.relayID,
config: {
"name": "Switch0",
"auto_on": false,
"auto_off": false,
}
Expand Down Expand Up @@ -818,7 +819,7 @@ function createScript(id) {
/** Add code to the watchdog script */
function putCode(res, err, msg, data) {
if (err === 0) {
print(_.pId, "Watchdog script has been created.");
// print(_.pId, "Watchdog script has been created.");
let scId = res.id > 0 ? res.id : data.id;
Shelly.call('Script.PutCode', { id: scId, code: watchdog }, startScript, { id: scId });
}
Expand All @@ -829,7 +830,7 @@ function putCode(res, err, msg, data) {
/** Enable autostart and start the watchdog script */
function startScript(res, err, msg, data) {
if (err === 0) {
print(_.pId, "Insert code to watchdog script completed.");
// print(_.pId, "Insert code to watchdog script completed.");
if (!Shelly.getComponentConfig("script", data.id).enable) {
Shelly.call('Script.SetConfig', { id: data.id, config: { enable: true } },
function (res, err, msg, data) {
Expand All @@ -840,7 +841,7 @@ function startScript(res, err, msg, data) {
}
Shelly.call('Script.Start', { id: data.id }, function (res, err, msg, data) {
if (err === 0) {
print(_.pId, "Watchdog script started succesfully.");
print(_.pId, "Watchdog script created and started succesfully.");
}
else {
print(_.pId, "Watchdog script is not started.", msg, ". Schedules are not deleted if heating script is stopped or deleted.");
Expand Down

0 comments on commit 8463a16