Zib-Respiration #283
Draft
Zib-Respiration #283
Annotations
9 errors and 10 warnings
|
resources/nl-core/nl-core-Respiration.AdministrationDevice.xml#L116
Constraint failed: sd-pg-11: 'If an alias exists and this element is not the root element, mapping.map needs to be present.' (defined in https://informatiestandaarden.nictiz.nl/wiki/FHIR:V1.0_FHIR_Profiling_Guidelines_R4) (at StructureDefinition.differential.element[12])
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FiO2.xml#L90
Constraint failed: sd-pg-16: 'Patterns should be used instead of fixed values (except for extension definitions)' (defined in http://nictiz.nl/fhir/StructureDefinition/ProfilingGuidelinesR4-StructureDefinitions) (at StructureDefinition.differential.element[6])
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FiO2.xml#L86
Constraint failed: sd-pg-16: 'Patterns should be used instead of fixed values (except for extension definitions)' (defined in http://nictiz.nl/fhir/StructureDefinition/ProfilingGuidelinesR4-StructureDefinitions) (at StructureDefinition.differential.element[5])
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FlowRate.xml#L102
Constraint failed: sd-pg-16: 'Patterns should be used instead of fixed values (except for extension definitions)' (defined in http://nictiz.nl/fhir/StructureDefinition/ProfilingGuidelinesR4-StructureDefinitions) (at StructureDefinition.differential.element[8])
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FlowRate.xml#L94
Constraint failed: sd-pg-16: 'Patterns should be used instead of fixed values (except for extension definitions)' (defined in http://nictiz.nl/fhir/StructureDefinition/ProfilingGuidelinesR4-StructureDefinitions) (at StructureDefinition.differential.element[7])
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FlowRate.xml#L90
Constraint failed: sd-pg-16: 'Patterns should be used instead of fixed values (except for extension definitions)' (defined in http://nictiz.nl/fhir/StructureDefinition/ProfilingGuidelinesR4-StructureDefinitions) (at StructureDefinition.differential.element[6])
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FlowRate.xml#L86
Constraint failed: sd-pg-16: 'Patterns should be used instead of fixed values (except for extension definitions)' (defined in http://nictiz.nl/fhir/StructureDefinition/ProfilingGuidelinesR4-StructureDefinitions) (at StructureDefinition.differential.element[5])
|
|
resources/zib/zib-Respiration.AdministrationDevice.Product.xml#L0
An ignored issue was provided, but the issue didn't occur (at zib-Respiration.AdministrationDevice.Product)
|
|
resources/zib/zib-Respiration.AdministrationDevice.xml#L45
Constraint failed: sd-zpg-03: 'References to other resource profiles should be added next to the HL7 base references, unless they are added on a slice.' (at StructureDefinition.differential.element[1])
|
|
resources/zib/terminology/manual/ConceptMap-ContactTypeCodeLijst-to-ActEncounterCode.xml#L72
The target display 'inpatient' for the code 'http://terminology.hl7.org/CodeSystem/v3-ActCode|9.0.0#IMP' is not valid. Possible displays: 'inpatient encounter' (at ConceptMap.group[0].element[4].target[0].code)
|
|
resources/zib/terminology/manual/ConceptMap-ContactTypeCodeLijst-to-ActEncounterCode.xml#L69
The source display 'Inpatient' for the code 'http://terminology.hl7.org/CodeSystem/v3-ActCode|9.0.0#IMP' is not valid. Possible displays: 'inpatient encounter' (at ConceptMap.group[0].element[4].code)
|
|
resources/zib/terminology/manual/ConceptMap-ContactTypeCodeLijst-to-ActEncounterCode.xml#L63
The target display 'home' for the code 'http://terminology.hl7.org/CodeSystem/v3-ActCode|9.0.0#HH' is not valid. Possible displays: 'home health' (at ConceptMap.group[0].element[3].target[0].code)
|
|
resources/zib/terminology/manual/ConceptMap-ContactTypeCodeLijst-to-ActEncounterCode.xml#L60
The source display 'Home' for the code 'http://terminology.hl7.org/CodeSystem/v3-ActCode|9.0.0#HH' is not valid. Possible displays: 'home health' (at ConceptMap.group[0].element[3].code)
|
|
resources/zib/ext-Comment.xml#L0
Review the extension type for ext-Comment: extensions should not have a context of Element unless it's really intended that they can be used anywhere (at StructureDefinition.context[0])
|
|
resources/nl-core/nl-core-Respiration.AdministrationDevice.xml#L0
Unable to resolve profile http://nictiz.nl/fhir/StructureDefinition/nl-core-HealthProfessional.PractitionerRole (at StructureDefinition.differential.element[2].type[0].targetProfile[0])
|
|
resources/nl-core/nl-core-Respiration.AdministrationDevice.xml#L0
Cannot check whether the target profile http://nictiz.nl/fhir/StructureDefinition/nl-core-HealthProfessional.PractitionerRole on DeviceUseStatement.extension.value[x] is valid constraint on the base because it is not known (at StructureDefinition.differential.element[2])
|
|
resources/zib/zib-Wound.Drain.Product.xml#L0
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.1.1--20200901000000 could not be expanded (at StructureDefinition)
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FlowRate.xml#L2
Constraint failed: sdf-0: 'Name should be usable as an identifier for the module by machine processing applications such as code generation' (defined in http://hl7.org/fhir/StructureDefinition/StructureDefinition) (at StructureDefinition)
|
|
resources/zib/zib-Respiration.AdministeredOxygen.FlowRate.xml#L2
Constraint failed: sd-pg-07: 'The name of the StructureDefinition should conform to the profiling guidelines' (defined in https://informatiestandaarden.nictiz.nl/wiki/FHIR:V1.0_FHIR_Profiling_Guidelines_R4) (at StructureDefinition)
|
The logs for this run have expired and are no longer available.