Skip to content

Add test case for item 9 in WECON #1301

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Open
wants to merge 1 commit into
base: master
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
229 changes: 229 additions & 0 deletions wecon_wtest/3D_WECON_9.DATA
Original file line number Diff line number Diff line change
@@ -0,0 +1,229 @@
-- This reservoir simulation deck is made available under the Open Database
-- License: http://opendatacommons.org/licenses/odbl/1.0/. Any rights in
-- individual contents of the database are licensed under the Database Contents
-- License: http://opendatacommons.org/licenses/dbcl/1.0/

-- Copyright (C) 2016 SINTEF ICT, Applied Mathematics
-- Copyright (C) 2016 Statoil
-- Copyright (C) 2018 IRIS
-- Copyright (C) 2025 Equinor

-- Is modified from 3D_WECON to test opening of follow on wells (item 9 in WECON)

RUNSPEC

DIMENS
30 20 6/

GRIDOPTS
'YES' 0 /

OIL

WATER

GAS

DISGAS

VAPOIL


METRIC


START
06 'NOV' 1997 /

EQLDIMS
1 /
-- 5 100 20 /

WELLDIMS
130 36 15 84 /


TABDIMS
--ntsfun ntpvt nssfun nppvt ntfip nrpvt ntendp
1 1 33 60 16 60 /

REGDIMS
1 1 1 0 /

PIMTDIMS
1 51 /

NSTACK
30 /

UNIFIN
UNIFOUT

---------------------------------------------------------
--
-- Input of grid geometry
--
---------------------------------------------------------
GRID

NEWTRAN

GRIDFILE
2 /

INIT

NOECHO

--------------------------------------------------------
--
-- Grid and faults
--
--------------------------------------------------------
INCLUDE
'common/GRDECL.INC' /

INCLUDE
'common/ACTNUM.INC' /

--------------------------------------------------------
--
-- Input of grid parametres
--
--------------------------------------------------------
INCLUDE
'common/PORO.INC' /

INCLUDE
'common/PERMX.INC' /

INCLUDE
'common/PERMY.INC' /

INCLUDE
'common/PERMZ.INC' /

--------------------------------------------------------------------------------

--------------------------------------------------------------------------------

PROPS

INCLUDE
'common/PROPS.INC' /

NOECHO


---------------------------------------------------------------------------------
SOLUTION

EQUIL
-- Datum P woc Pc goc Pc Rsvd Rvvd
2010 269.46 2120 0.0 2010.0 0.0 1* 0 0/

RPTSOL
FIP=3 SWAT SGAS PRESS SOIL /

SUMMARY

WOPR
'PROD01'
'PROD02'
/

WGPR
'PROD01'
'PROD02'
/

WBHP
'INJE01'
'PROD01'
'PROD02'
/

WWIR
'INJE01'
/

WWPR
'PROD01'
'PROD02'
/

WWCT
'PROD01'
'PROD02'
/

CWCT
'PROD01' /
'PROD02' /
/

COPR
'PROD01' /
'PROD02' /
/
ALL
--------------------------------------------------------------------------------


SCHEDULE

RPTRST
BASIC=2 /

NOECHO

WELSPECS
'INJE01' 'I' 13 10 1* 'WATER' /
'PROD01' 'P' 24 16 1* 'OIL' 7* /
'PROD02' 'P' 9 9 1* 'OIL' 7* /
/

COMPDAT
'INJE01' 13 10 4 6 'OPEN' 1* 181.866 0.5 /
'PROD01' 24 16 1 2 'OPEN' 1* 218.457 0.5 /
'PROD02' 9 9 1 6 'OPEN' 1* 218.457 0.5 /
/
COMPLUMP
'PROD02' 2* 1 2 1/
'PROD02' 2* 3 4 2/
/

WCONPROD
'PROD01' 'OPEN' 'BHP' 5* 230 /
'PROD02' 'SHUT' 'BHP' 5* 230 /
/

WECON
'PROD01' 1000 4* WELL NO 'PROD02' /
-- 'PROD02' 1* 800 0.1 2* CON NO /
/

WTEST
'PROD01' 100 E /
-- 'PROD02' 100 E /
/

WCONINJE
'INJE01' 'WATER' 'OPEN' 'RATE' 250.00 1* 290 /
/

TSTEP
1
3
6
10
/

WCONINJE
'INJE01' 'WATER' 'OPEN' 'RATE' 5000.00 1* 290 /
/

TSTEP
50*30
/