Skip to content

Mb/matpower transformer shunts#1422

Merged
jd-lara merged 2 commits into
psy5from
mb/matpower-transformer-shunts
Jun 18, 2025
Merged

Mb/matpower transformer shunts#1422
jd-lara merged 2 commits into
psy5from
mb/matpower-transformer-shunts

Conversation

@m-bossart

Copy link
Copy Markdown
Contributor

Reflect the shunt for a matpower transformer to the primary side.

@m-bossart m-bossart requested a review from rodrigomha June 17, 2025 23:00
@m-bossart

Copy link
Copy Markdown
Contributor Author

Related to PowerFlows#179

@rodrigomha rodrigomha left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This seems to be OK. In Matpower, a branch is always a transformer if it has tap different than zero right?

@m-bossart

Copy link
Copy Markdown
Contributor Author

This seems to be OK. In Matpower, a branch is always a transformer if it has tap different than zero right?

Yes I believe so. Transformers always have non-zero tap and lines always have zero tap

@jd-lara jd-lara self-assigned this Jun 18, 2025
@jd-lara jd-lara merged commit 0d42a68 into psy5 Jun 18, 2025
1 of 9 checks passed
@jd-lara jd-lara deleted the mb/matpower-transformer-shunts branch July 15, 2025 04:14