16 changes: 8 additions & 8 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -3,9 +3,9 @@
This repository contains a collection of my custom components
for [ESPHome](https://esphome.io/).

[!["Buy Me A Coffee"](https://github.com/SzczepanLeon/esphome-components/blob/main/docs/buy_me_coffe.png)](https://www.buymeacoffee.com/szczepan)
[!["Buy Me A Coffee"](https://github.com/SzczepanLeon/esphome-components/blob/version_4/docs/buy_me_coffe.png)](https://www.buymeacoffee.com/szczepan)
\
[!["Kup mi kawę"](https://github.com/SzczepanLeon/esphome-components/blob/main/docs/postaw_kawe.png)](https://buycoffee.to/szczepanleon)
[!["Kup mi kawę"](https://github.com/SzczepanLeon/esphome-components/blob/version_4/docs/postaw_kawe.png)](https://buycoffee.to/szczepanleon)


## 1. Usage
Expand All @@ -15,7 +15,7 @@ with external components and add this to your `.yaml` definition:

```yaml
external_components:
- source: github://SzczepanLeon/esphome-components@main
- source: github://SzczepanLeon/esphome-components@version_4
```

## 2. Components
Expand All @@ -24,11 +24,11 @@ external_components:

Component to receive wMBus frame (via CC1101), create HA sensor and send decoded value.
You can also use this component with wmbusmeters HA addon:
https://github.com/SzczepanLeon/esphome-components/blob/main/docs/wmbus.md
https://github.com/SzczepanLeon/esphome-components/blob/version_4/docs/wmbus.md

[!["CC1101 to D1 mini PCB"](https://github.com/SzczepanLeon/esphome-components/blob/main/docs/pcb_v2.png)](https://www.pcbway.com/project/shareproject/CC1101_to_ESP_D1_mini_277f34e1.html)
[!["CC1101 to D1 mini PCB"](https://github.com/SzczepanLeon/esphome-components/blob/version_4/docs/pcb_v2.png)](https://www.pcbway.com/project/shareproject/CC1101_to_ESP_D1_mini_277f34e1.html)

> **_NOTE:_** Configuration for version 3.x is described [here](https://github.com/SzczepanLeon/esphome-components/blob/main/docs/version_3.md)
> **_NOTE:_** Configuration for version 3.x is described [here](https://github.com/SzczepanLeon/esphome-components/blob/version_4/docs/version_3.md)

#### 2.1.1. Fast start

Expand Down Expand Up @@ -75,7 +75,7 @@ You can decode that telegram on [wmbusmeters](https://wmbusmeters.org/analyze/4E

- everything is known, let's find field and unit
From decoded JSON:
![decoded JSON](https://github.com/SzczepanLeon/esphome-components/blob/main/docs/decoded_telegram.png)
![decoded JSON](https://github.com/SzczepanLeon/esphome-components/blob/version_4/docs/decoded_telegram.png)

find interesting data (in that case total_m3), split it into field (total) and unit (m3) and create sensor in YAML. In YAML config please use units from HA (ie. "m³" not "m3", etc).

Expand Down Expand Up @@ -114,7 +114,7 @@ time:
id: time_sntp

external_components:
- source: github://SzczepanLeon/esphome-components@main
- source: github://SzczepanLeon/esphome-components@version_4
refresh: 0d
components: [ wmbus ]

Expand Down
4 changes: 2 additions & 2 deletions components/wmbus/driver_apator162.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -72,7 +72,7 @@ namespace
vector<uchar> content;
t->extractPayload(&content);

map<string,pair<int,DVEntry>> vendor_values;
std::map<std::string,pair<int,DVEntry>> vendor_values;

// The first 8 bytes are error flags and a date time.
// E.g. 0F005B5996000000 therefore we skip the first 8 bytes.
Expand Down Expand Up @@ -246,7 +246,7 @@ namespace

void Driver::processExtras(string miExtras)
{
map<string,string> extras;
std::map<std::string,std::string> extras;
bool ok = parseExtras(miExtras, &extras);
if (!ok)
{
Expand Down
138 changes: 118 additions & 20 deletions components/wmbus/driver_hydrodigit.cpp
Original file line number Diff line number Diff line change
@@ -1,5 +1,6 @@
/*
Copyright (C) 2019-2023 Fredrik Öhrström (gpl-3.0-or-later)
Extended 2025 to support frame 0x03 (BATTERY_VOLTAGE FRAUD_DATE)

This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
Expand All @@ -20,6 +21,10 @@
#include<string.h>

namespace {
using std::string;
using std::vector;
using std::shared_ptr;

struct Driver: public virtual MeterCommonImplementation {
Driver(MeterInfo &mi, DriverInfo &di);
void processContent(Telegram *t);
Expand All @@ -34,6 +39,7 @@ namespace {
di.addDetection(MANUFACTURER_BMT, 0x06, 0x17);
di.addDetection(MANUFACTURER_BMT, 0x07, 0x13);
di.addDetection(MANUFACTURER_BMT, 0x07, 0x15);
di.addDetection(MANUFACTURER_BMT, 0x07, 0x17);
di.usesProcessContent();
di.setConstructor([](MeterInfo &mi, DriverInfo &di) {
return shared_ptr<Meter>(new Driver(mi, di));
Expand All @@ -55,14 +61,25 @@ namespace {
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build().set(MeasurementType::Instantaneous).set(
VIFRange::DateTime), Unit::DateTimeLT);

addStringField("contents", "Contents of this telegrams",
DEFAULT_PRINT_PROPERTIES);

addNumericField("voltage", Quantity::Voltage, DEFAULT_PRINT_PROPERTIES,
"Voltage of the battery inside the meter", Unit::Volt);

addStringField("fraud_date", "Date of fraud/tampering detected by meter",
DEFAULT_PRINT_PROPERTIES);

addStringField("fraud_type", "Type of fraud/tampering detected",
DEFAULT_PRINT_PROPERTIES);

addStringField("leak_date", "Date of leakage detected by meter",
DEFAULT_PRINT_PROPERTIES);

addNumericField("backflow", Quantity::Volume, DEFAULT_PRINT_PROPERTIES,
"Backflow detected by the meter", Unit::M3);

addNumericField("January_total", Quantity::Volume,
DEFAULT_PRINT_PROPERTIES, "Total value at the end of January",
Unit::M3);
Expand Down Expand Up @@ -175,7 +192,16 @@ namespace {
default:
return 3.7; // 0, E and F all are 3.7
}
}

string getFraudType(uchar fraud_byte1, uchar fraud_byte2, uchar fraud_byte3) {
// Check if all bytes are 0x00 (no fraud detected)
if (fraud_byte1 == 0x00 && fraud_byte2 == 0x00 && fraud_byte3 == 0x00) {
return "no type info";
}
// If there's any non-zero value, it indicates some type of fraud
// The actual fraud type encoding needs to be documented by manufacturer
return "detected";
}

void Driver::processContent(Telegram *t) {
Expand All @@ -192,19 +218,92 @@ namespace {

if (i >= len) return;
uchar frame_identifier = bytes[i];
if (frame_identifier == 0x15) {

// Frame 0x03: BATTERY_VOLTAGE FRAUD_DATE
if (frame_identifier == 0x03) {
t->addSpecialExplanation(i + offset, 1, KindOfData::PROTOCOL,
Understanding::FULL, "*** %02X frame content: %s",
frame_identifier, "Battery voltage and fraud date");
setStringValue("contents", "BATTERY_VOLTAGE FRAUD_DATE");
i++;

// Process voltage
if (i >= len) return;
uchar somethingAndVoltage = bytes[i];
double voltage = getVoltage(somethingAndVoltage & 0x0F);
t->addSpecialExplanation(i + offset, 1, KindOfData::CONTENT,
Understanding::FULL,
"*** %02X voltage of battery %0.2f V",
somethingAndVoltage, voltage);
setNumericValue("voltage", Unit::Volt, voltage);
i++;

// Process fraud date (3 bytes: DD MM YY in BCD format)
if (i + 2 >= len) return;
uchar fraud_day = bytes[i];
uchar fraud_month = bytes[i + 1];
uchar fraud_year = bytes[i + 2];

// Determine fraud type
string fraud_type = getFraudType(fraud_day, fraud_month, fraud_year);
setStringValue("fraud_type", fraud_type);

// Format fraud date
char fraud_buffer[17];
memset(fraud_buffer, 0, sizeof(fraud_buffer));
if (fraud_day == 0x00 && fraud_month == 0x00 && fraud_year == 0x00) {
// No fraud detected
snprintf(fraud_buffer, 16, "2000-00-00");
t->addSpecialExplanation(i + offset, 3, KindOfData::CONTENT,
Understanding::FULL,
"*** %02X%02X%02X fraud date: %02X.%02X.20%02X [%s]",
fraud_day, fraud_month, fraud_year,
fraud_day, fraud_month, fraud_year, fraud_type.c_str());
} else {
// Fraud detected - format as proper date
snprintf(fraud_buffer, 16, "20%02X-%02X-%02X", fraud_year, fraud_month, fraud_day);
t->addSpecialExplanation(i + offset, 3, KindOfData::CONTENT,
Understanding::FULL,
"*** %02X%02X%02X fraud date: %02X.%02X.20%02X [%s]",
fraud_day, fraud_month, fraud_year,
fraud_day, fraud_month, fraud_year, fraud_type.c_str());
}
setStringValue("fraud_date", fraud_buffer);
i += 3;

// Check for additional unknown data
if (i < len) {
uchar unknown = bytes[i];
t->addSpecialExplanation(i + offset, 1, KindOfData::CONTENT,
Understanding::NONE,
"*** %02X unknown data",
unknown);
i++;
}

return; // End processing for frame 0x03
}

// Frame 0x15: Backflow, alarms and monthly data
else if (frame_identifier == 0x15) {
t->addSpecialExplanation(i + offset, 1, KindOfData::PROTOCOL,
Understanding::FULL, "*** %02X frame content: %s",
frame_identifier, "Backflow, alarms and monthly data");
setStringValue("contents", "Backflow, alarms and monthly data");
} else if (frame_identifier == 0x95) {
}

// Frame 0x95: Backflow, leak date, alarms and monthly data
else if (frame_identifier == 0x95) {
t->addSpecialExplanation(i + offset, 1, KindOfData::PROTOCOL,
Understanding::FULL, "*** %02X frame content: %s",
frame_identifier,
"Backflow, leak date, alarms and monthly data");
setStringValue("contents",
"Backflow, leak date, alarms and monthly data");
} else {
}

// Unknown frame
else {
t->addSpecialExplanation(i + offset, 1, KindOfData::PROTOCOL,
Understanding::NONE,
"*** %02X frame content unknown, please open issue with this telegram for driver improvement",
Expand All @@ -215,12 +314,8 @@ namespace {
}
i++;


// Process voltage (for frames 0x15 and 0x95)
if (i >= len) return;
// only the bottom half changes the voltage, top half's purpose is unknown
// values obtained from software by changing value from 0x00-0F
// changing the top half didn't seem to change anything, but it might require a combination with other bytes
// my meters have 0x0A and 0x2A but the data seems same
uchar somethingAndVoltage = bytes[i];
double voltage = getVoltage(somethingAndVoltage & 0x0F);
t->addSpecialExplanation(i + offset, 1, KindOfData::CONTENT,
Expand All @@ -230,13 +325,13 @@ namespace {
setNumericValue("voltage", Unit::Volt, voltage);
i++;


// Process leak date (only for frame 0x95)
if (frame_identifier == 0x95) {
if (i + 2 >= len) return;
uchar leak_year = bytes[i];
uchar leak_month = bytes[i + 1];
uchar leak_day = bytes[i + 2];
// its BCD so I just print it as is

t->addSpecialExplanation(i + offset, 3, KindOfData::CONTENT,
Understanding::FULL,
"*** %02X%02X%02X date of leakage: %02X.%02X.20%02X",
Expand All @@ -251,9 +346,8 @@ namespace {
i += 3;
}


// Process backflow (for frames 0x15 and 0x95)
if (i + 3 >= len) return;
// backflow detected by the meter, has higher precision than normal values
double backflow = fromBackflow(bytes[i], bytes[i + 1], bytes[i + 2],
bytes[i + 3]);
t->addSpecialExplanation(i + offset, 4, KindOfData::CONTENT,
Expand All @@ -264,17 +358,18 @@ namespace {

i += 4;

// Process monthly data (for frames 0x15 and 0x95)
double monthData;
string month_field_name;
for (int month = 1; month <= 12; ++month) {
if (i + 2 >= len) return;
month_field_name.clear();
month_field_name.append(getMonth(month)).append("_total");
monthData = fromMonthly(bytes[i], bytes[i + 1], bytes[i + 2]);
// one of our meters was installed backwards so we know the max value is 99999,99
// anything above (which should only be FFFFFF, more on that below) should be 0

// FFFFFF (167772,15) means module was not active back then (before installation) - translates to 0
if (monthData >= 100000) monthData = 0;

t->addSpecialExplanation(i + offset, 3, KindOfData::CONTENT,
Understanding::FULL,
"*** %02X%02X%02X total consumption at the end of %s: %0.2f m3",
Expand All @@ -285,16 +380,14 @@ namespace {
i += 3;
}

// Process unknown trailing byte (for frames 0x15 and 0x95)
if (i >= len) return;
// changing this byte didn't seem to do anything
// and it's always 00 on my meters
uchar unknown = bytes[i];
t->addSpecialExplanation(i + offset, 1, KindOfData::CONTENT,
Understanding::NONE,
"*** %02X unknown data",
unknown);
i++;
// there should not be any more data
}
}

Expand All @@ -304,20 +397,25 @@ namespace {
// |HydrodigitWater;86868686;3.866;2019-10-30 08:39;1111-11-11 11:11.11

// Test: HydridigitWaterr hydrodigit 03245501 NOKEY
// Comment: Frame 0x03 with battery voltage and fraud date
// telegram=|2444B4090155240317068C00487AC0000000_0C1335670000046D172EEA280F030000000000|
// {"contents": "unknown, please open issue with this telegram for driver improvement","id": "03245501","media": "warm water","meter": "hydrodigit","meter_datetime": "2023-08-10 14:23","name": "HydridigitWaterr","timestamp": "1111-11-11T11:11:11Z","total_m3": 6.735}
// {"contents": "BATTERY_VOLTAGE FRAUD_DATE","fraud_date":"2000-00-00","fraud_type":"no type info","id": "03245501","media": "warm water","meter": "hydrodigit","meter_datetime": "2023-08-10 14:23","name": "HydridigitWaterr","timestamp": "1111-11-11T11:11:11Z","total_m3": 6.735,"voltage_v":3.7}
// |HydridigitWaterr;03245501;6.735;2023-08-10 14:23;1111-11-11 11:11.11


// Test: Hydro3 hydrodigit 87654321 NOKEY
// Comment: This is a nice one to showcase the backflow encoding.
// telegram=|4644B4092143658713077A9C000000_0C1364390400_046D212F1635_0F152A0F000000440F00C00F00511000D51000B20B00180C007C0C00E60C00560D00D10D00400E00C60E0000|
// {"media":"water","meter":"hydrodigit","name":"Hydro3","id":"87654321","April_total_m3":43.09,"August_total_m3":33.02,"December_total_m3":37.82,"February_total_m3":40.32,"January_total_m3":39.08,"July_total_m3":31.96,"June_total_m3":30.96,"March_total_m3":41.77,"May_total_m3":29.94,"November_total_m3":36.48,"October_total_m3":35.37,"September_total_m3":34.14,"backflow_m3":0.015,"meter_datetime":"2024-05-22 15:33","total_m3":43.964,"voltage_v":3.05,"contents":"Backflow, alarms and monthly data","timestamp":"1111-11-11T11:11:11Z"}
// |Hydro3;87654321;43.964;2024-05-22 15:33;1111-11-11 11:11.11


// Test: Hydro4 hydrodigit 87654322 NOKEY
// Comment: This one adds a leak date to the definition, plus shows how the monthly data looks before module installation.
// telegram=|4944B4092243658713077A7F000000_0C1363020400_046D242C1236_0F950A24042507000000A405006E0700850900CA0B004A0E00FFFFFFFFFFFF020000020000250000B3010095030000|
// {"media":"water","meter":"hydrodigit","name":"Hydro4","id":"87654322","April_total_m3":30.18,"August_total_m3":0.02,"December_total_m3":9.17,"February_total_m3":19.02,"January_total_m3":14.44,"July_total_m3":0,"June_total_m3":0,"March_total_m3":24.37,"May_total_m3":36.58,"November_total_m3":4.35,"October_total_m3":0.37,"September_total_m3":0.02,"backflow_m3":0.007,"meter_datetime":"2024-06-18 12:36","total_m3":40.263,"voltage_v":3.05,"contents":"Backflow, leak date, alarms and monthly data","leak_date":"25.04.2024","timestamp":"1111-11-11T11:11:11Z"}
// |Hydro4;87654322;40.263;2024-06-18 12:36;1111-11-11 11:11.11

// Test: HydroFrame03 hydrodigit 03273936 NOKEY
// Comment: Frame 0x03 - Battery voltage and fraud date (your telegram)
// telegram=|2144B4093639270317077A23000000_0C1310000000046D0C2F263B0F030000000000|
// {"contents":"BATTERY_VOLTAGE FRAUD_DATE","fraud_date":"2000-00-00","fraud_type":"no type info","id":"03273936","media":"water","meter":"hydrodigit","meter_datetime":"2025-11-06 15:12","name":"HydroFrame03","timestamp":"1111-11-11T11:11:11Z","total_m3":0.01,"voltage_v":3.7}
// |HydroFrame03;03273936;0.01;2025-11-06 15:12;1111-11-11 11:11.11
11 changes: 11 additions & 0 deletions components/wmbus/driver_hydrus.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -31,6 +31,7 @@ namespace
di.setDefaultFields("name,id,total_m3,total_at_date_m3,status,timestamp");
di.setMeterType(MeterType::WaterMeter);
di.addLinkMode(LinkMode::T1);
di.addLinkMode(LinkMode::C1);
di.addDetection(MANUFACTURER_DME, 0x07, 0x70);
di.addDetection(MANUFACTURER_DME, 0x07, 0x76);
di.addDetection(MANUFACTURER_HYD, 0x07, 0x24);
Expand Down Expand Up @@ -88,6 +89,16 @@ namespace
.set(StorageNr(1))
);

addNumericFieldWithExtractor(
"flow_temperature_c",
"The flow temperature",
DEFAULT_PRINT_PROPERTIES,
Quantity::Temperature,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::FlowTemperature));

addNumericFieldWithExtractor(
"flow",
"The current water flow.",
Expand Down
10 changes: 10 additions & 0 deletions components/wmbus/driver_unismart.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -159,6 +159,16 @@ namespace
.set(IndexNr(2))
);

addNumericFieldWithExtractor(
"battery",
"Remaining battery life in days.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Time,
VifScaling::None, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::RemainingBattery),
Unit::Day);
}
}

Expand Down