FreeStreamVelocityCorrection is causing unexpected changes in the density distribution and incorrect velocity profile near the outlet

@Xiangyu-Hu
Copy link
Owner

How long is the runtime of this test?

@anastazja-virtonomy
Copy link
Contributor Author

The test is set for 200 sec. of physical time, but the flow disturbance is visible already after 1-2 sec. which took around 1 min to simulate on my PC

@Xiangyu-Hu
Copy link
Owner

The test is set for 200 sec. of physical time, but the flow disturbance is visible already after 1-2 sec. which took around 1 min to simulate on my PC

Does problem solved?

@YuVirtonomy
Copy link
Collaborator

The test is set for 200 sec. of physical time, but the flow disturbance is visible already after 1-2 sec. which took around 1 min to simulate on my PC

Does problem solved?

This problem is solved.

  • Need to add TimeDependentAcceleration
  • Should not use parabolic flow for the inlet but uniform flow.
    I think this pull/issue should be closed

@Xiangyu-Hu
Copy link
Owner

The test is set for 200 sec. of physical time, but the flow disturbance is visible already after 1-2 sec. which took around 1 min to simulate on my PC

Does problem solved?

This problem is solved.

  • Need to add TimeDependentAcceleration
  • Should not use parabolic flow for the inlet but uniform flow.
    I think this pull/issue should be closed

Could you make a ci test in the pull request ao that we can merge it to master. Thanks.

@Xiangyu-Hu Xiangyu-Hu linked an issue Mar 1, 2023 that may be closed by this pull request
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

FreeStreamVelocityCorrection not working properly in 3D

3 participants