You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This commit was created on GitHub.com and signed with GitHub’s verified signature.
1.1.0 (2025-10-07)
DATE (Major UI Change)
Support additional method of entry of Duration objects:
compact string form, {dd}D{hh}H{mm}M{ss}S, e.g. 1D30M2S for DR{1,0,30,2}.
Obsoletes the "Duration Colon Modifier" entry form {nn}:{modifier}. Currently retained for backwards
compatibility.
incremental building of Duration components using the DAY>, HR>, MIN>, and SEC> menu functions
Add MenuFolder for the 7 Date types: D, T, DT, TZ, DZ, DR, DW
add convenience menu function that inserts the Date-type prefix
(i.e. "D{", "T{", "DT{", "TZ{", "DZ{", "DR{", "DW{"), to make
entering Date-objects much easier
add complete list of polymorphic functions that apply to each
Date-object under each menu folder
Remove DOPS folder, and scatter its functions (LEAP, DSHK, DEXD, DCUT, DLNK) under the 3 Date-object folders which support
them: D, DT, DZ
Assume that DT (DateTime) is always in UTC timezone whenever its
timezone is needed in a calculation
HMS functions
New Add HMS+ and HMS- menu functions under CONV menu folder.
Bug Fix: Add normalization to >HMS conversion function to
prevent bug that caused [1.32] [1.32] [HMS+] to return 3.0360
instead of 3.04.
Validate mm and ss fields of hh.mmss and throw Err:Invalid if
greater than than 60.
UNIT menu (Complete Reimplementation)
Reimplement the underlying architecture using a workflow similar to
the UNITS menu of the HP-19BII and TI-85
Pressing a UNIT menu converts a Real number to a Denominate number
(i.e. a number with units).
Pressing a subsequent UNIT menu converts that Denominate number
into the unit requested by the menu key.
Support misc Unit Functions (UFCN)
UVAL: return display value without units
UBAS: convert to its "base unit"
Increase number of supported units from 30 to 169.
Support all units in the HP-19BII and the TI-85.
Reorganize UNIT menus across 13 sub MenuFolders: UFCN, LENG, AREA,
VOL, TEMP, MASS, FORC, PRES, ENER, TIME, SPD, PWR, FUEL.
Support basic arithmetic operations on units: CHS, +, -, *, /
Support most NUM operations on units: %, %CH, IP, FP, FLR,CEIL, NEAR, ABS, SIGN, MOD, MIN, MAX, RNDF, RNDN, RNDG (i.e. all NUM functions except GCD, LCM, and PRIM)
Support Storage Register arithmetics with UNIT objects.
BASE (UI Reorganization)
move most menu functions under 5 new subfolders: LOGI, ROTS, BITS,
BFCN, BCFS ("Configs" or "Carry Flag and Word Size")
rename (B+ B- B* B/) to (BAS+ BAS- BAS* BAS/) for better
self-documentation
no functional change
RPN Stack (Bug Fixes)
Bug Fix: Fix incorrect stack lift behavior for functions that
produce a value without consuming the X register (e.g. PI, E, MEAN).
Previously, these functions would ignore the 'disable stack lift'
setting. Now, they will correctly interpret that flag and overwrite
the existing X register.
Bug Fix: Preserve LASTX during CLST (Clear Stack), consistent
with HP-42S.
Bug Fix: Handle an empty string input buffer correctly for all
commands including the 'disable stack lift' behavior.
Handle edge case of STO which consumes X but spits back the same
value. Input termination must occur and stack lift must be enabled.
Terminate input buffer and correctly enable stack lift for stack
manipulation commands: DUP, Rollup, Rolldown, DROP, X<>Y.
Input Termination (Consistency)
Update all functions and menu navigation to avoid input termination
for as long as it makes sense. See the new Input
Termination section for
full details.
Key bindings (New)
Add 2ND v as a shortcut to UVAL menu function under UNIT. Allows
quick extraction of the value part of a Denominate object.
SHOW (Workflow)
Pass along most button keys to the main command processor so that
their normal function are directly invoked from SHOW mode. Previously,
all button presses were consumed by the SHOW mode. So to enter a new
number from SHOW mode, the digit key (0-9) had to be pressed twice.
Preserve previous behavior for 4 buttons: DEL, CLEAR, ENTER, ON/EXIT. These buttons are consumed by the SHOW mode, and simply
cause the SHOW mode to exit back to the normal mode. The user must
press these buttons again in normal mode to invoke their normal
function.
RPN83P application size
increase to 64kiB (4 flash pages) from 48kiB
WARNING Most MODE settings will be lost when upgrading from v1.0 to
v1.1. Variables and registers will be preserved.
Lost
Pending entry in the input buffer
FIX, SCI, ENG selection
Trig modes (DEG, RAD)
Complex result (CRES,RRES)
Complex display modes (RECT, PRAD, PDEG)
,EE or EE, selection
{..} or ".." selection
'BASE > DEC|BIN|OCT|HEX' selection
'BASE > WSIZ' selection
'BASE > CF' flag
'DATE > EPCH' selection and custom epoch date
'DATE > CLK > ATZ' application timezone
'DATE > CLK > CTZ' clock timezone
TVM Solver parameters: IYR1, IYR2, TMAX
Preserved
Storage registers (R00-R99)
Storage variables (A-Z,Theta)
RPN stack registers (X,Y,Z,T,A,B,C,D)
STAT registers (ΣX to ΣYLX)
TVM variables: N, I%YR, PV, PMT, FV, P/YR, C/YR, BEG, END