Caution
Working with high voltage is dangerous. Always follow local laws and regulations regarding high voltage work. If you are unsure about the rules in your country, consult a licensed electrician for more information.
- Schneider XW Pro Hybrid Inverter
⚠️ Testing ongoing SCHNEIDER_CAN
The Schneider inverter works via CAN. The CAN connection is done at the Gateway


ℹ️ Always check the termination resistance of the system! That way you know if resistor needs to be removed or not.
ℹ️ Grounding is extremely important. Make sure the battery case is connected to protective earth, and the shield part of the twisted pair CAN is connected to PE also! Failing to do this will result in CAN errors.
For this inverter type, use the option called "Schneider V2 SE BMS CAN" under the "Inverter Protocol" setting