Support for Hoymiles HMT/HMS DTU PRO S Modbus TCP #29281
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Draft
jonilehtola
wants to merge
7
commits into
evcc-io:master
Choose a base branch
from
jonilehtola:feat/hoymiles-dtu
base: master
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
+191
−0
Draft
Changes from 5 commits
Commits
Show all changes
7 commits
Select commit
Hold shift + click to select a range
0a35cbf
First ver for yaml
jonilehtola 570b25a
Hoymiles DTU Modbus read working
jonilehtola 17887d6
Renaming of hoymiles-dtu-module
jonilehtola 2404ea9
Hoymiles-DTU: Changed end of panels behaviour. Robustness improvemen…
jonilehtola 3f62d83
Added newline at the end of file, quotation marks around description
jonilehtola 9834eb9
Device constraint in a const/hoymiles-dtu-mbtcp.go
jonilehtola 8da4567
Commentation clarification + inverter serial number conversion fix
jonilehtola File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,141 @@ | ||
| package meter | ||
|
|
||
| import ( | ||
| "context" | ||
| "encoding/binary" | ||
| "fmt" | ||
| "net" | ||
| "time" | ||
|
|
||
| "github.com/evcc-io/evcc/api" | ||
| "github.com/evcc-io/evcc/util" | ||
| "github.com/evcc-io/evcc/util/modbus" | ||
| ) | ||
|
|
||
| func init() { | ||
| registry.Add("hoymiles-dtu-mb", NewHoymilesDTUModbusTcpFromConfig) | ||
| } | ||
|
|
||
| type HoymilesDTUModbusTcpConfig struct { | ||
| Host string | ||
| Port string | ||
| ID uint8 | ||
| MaxACPower int | ||
| Cache time.Duration | ||
| } | ||
|
|
||
| type hoymilesDTUValues struct { | ||
| power float64 | ||
| totalEnergy float64 | ||
| } | ||
|
|
||
| type HoymilesDTUModbusTcp struct { | ||
| log *util.Logger | ||
| conn *modbus.Connection | ||
| maxAC float64 | ||
| valuesG func() (hoymilesDTUValues, error) | ||
| } | ||
|
|
||
| // NewHoymilesDTUModbusTcpFromConfig creates a Hoymiles DTU meter from generic config | ||
| func NewHoymilesDTUModbusTcpFromConfig(other map[string]any) (api.Meter, error) { | ||
| cc := HoymilesDTUModbusTcpConfig{ | ||
| Port: "502", | ||
| ID: 1, | ||
| Cache: time.Second * 15, | ||
| // cache results for 15 seconds to avoid hitting the DTU too often | ||
| } | ||
|
|
||
| if err := util.DecodeOther(other, &cc); err != nil { | ||
| return nil, err | ||
| } | ||
|
|
||
| uri := net.JoinHostPort(cc.Host, cc.Port) | ||
|
|
||
| modbus.Lock() | ||
| defer modbus.Unlock() | ||
|
|
||
| conn, err := modbus.NewConnection(context.Background(), uri, "", "", 0, modbus.Tcp, cc.ID) | ||
| if err != nil { | ||
| return nil, err | ||
| } | ||
|
|
||
| res := &HoymilesDTUModbusTcp{ | ||
| log: util.NewLogger("hoymiles-dtu-mb"), | ||
| conn: conn, | ||
| maxAC: float64(cc.MaxACPower), | ||
| } | ||
|
|
||
| res.valuesG = util.Cached(res.readCurrentValues, cc.Cache) | ||
|
|
||
| maxACPower := pvMaxACPower{MaxACPower: float64(cc.MaxACPower)} | ||
| return decorateMeter(res, res.TotalEnergy, nil, nil, nil, maxACPower.Decorator()), nil | ||
| } | ||
|
|
||
| var _ api.Meter = (*HoymilesDTUModbusTcp)(nil) | ||
|
|
||
| // Function to read single panel power from the DTU | ||
| // param panelIndex: the index of the panel to read (starting from 0), | ||
| // and modbus session, and returns the power in watts, or an error if the read fails | ||
| // returns the power in watts, totalCumulativeProduction in Wh, a flag indicating whether a panel exists, or an error if the read fails | ||
| func (m *HoymilesDTUModbusTcp) PanelPower(panelIndex int) (float64, float64, bool, error) { | ||
| PORT_LENGTH := uint16(0x28) // length of the data for each panel in bytes | ||
| START_REGISTER := uint16(0x1000) // starting register for the first panel | ||
| // calculate the starting register for the panel based on the index | ||
| startRegister := START_REGISTER + uint16(panelIndex)*PORT_LENGTH | ||
| // read PORT_LENGTH bytes from the DTU starting at startRegister | ||
| results, err := m.conn.ReadHoldingRegisters(startRegister, PORT_LENGTH) | ||
| if err != nil { | ||
| return 0, 0, false, fmt.Errorf("Failed to read hoymiles-dtu panel %d: %w", panelIndex, err) | ||
| } | ||
| // check that results has at least 24 bytes (to read power and total cumulative production) | ||
| if len(results) < 24 { | ||
| return 0, 0, false, fmt.Errorf("Invalid response length for panel %d: expected at least 24 bytes, got %d", panelIndex, len(results)) | ||
| } | ||
|
|
||
| // inverterSerial in 0x1 – 0x6, hex to string | ||
| serialBytes := results[1:6] | ||
| inverterSerial := fmt.Sprintf("%X", serialBytes) | ||
| serialIsZero := binary.BigEndian.Uint32(serialBytes[:4]) == 0 && serialBytes[4] == 0 | ||
| // portNumber in 0x7, hex to int | ||
| portNumber := int(results[7]) | ||
| if serialIsZero || portNumber == 0 { | ||
| m.log.TRACE.Printf("Panel %d: No more panels to read", panelIndex) | ||
| // if the serial number is all zeros or the port number is zero, we assume there are no more panels to read | ||
| return 0, 0, false, nil | ||
| } | ||
| // power in 0x10 – 0x11, hex to uint16, divided by 10 to get actual power in watts (one decimal place precision) | ||
| power := float64(binary.BigEndian.Uint16(results[16:18])) / 10.0 | ||
| // totalCumulativeProduction in bytes 0x14 – 0x17, hex to uint32, in Wh | ||
| totalCumulativeProduction := binary.BigEndian.Uint32(results[20:24]) // in Wh | ||
| m.log.TRACE.Printf("Panel %d: Inverter Serial: %s, Port Number: %d, Power: %.1f W, Total Cumulative Production: %d Wh", panelIndex, inverterSerial, portNumber, power, totalCumulativeProduction) | ||
| return power, float64(totalCumulativeProduction), true, nil | ||
| } | ||
|
|
||
| func (m *HoymilesDTUModbusTcp) readCurrentValues() (hoymilesDTUValues, error) { | ||
| var values hoymilesDTUValues | ||
| for i := 0; i < 99; i++ { | ||
|
sourcery-ai[bot] marked this conversation as resolved.
Outdated
|
||
| power, cumulative, found, err := m.PanelPower(i) | ||
| if err != nil { | ||
| return hoymilesDTUValues{}, fmt.Errorf("Failed to read hoymiles-dtu-panel %d: %w", i, err) | ||
| } | ||
| if !found { | ||
| break | ||
| } | ||
| values.power += power | ||
| values.totalEnergy += cumulative | ||
| } | ||
| m.log.DEBUG.Printf("Total power from all panels: %.2f W / %.2f W, Total cumulative production: %.2f Wh", values.power, m.maxAC, values.totalEnergy) | ||
| return values, nil | ||
| } | ||
|
|
||
| // CurrentPower implements the api.Meter interface | ||
| func (m *HoymilesDTUModbusTcp) CurrentPower() (float64, error) { | ||
| res, err := m.valuesG() | ||
| return res.power, err | ||
| } | ||
|
|
||
| // TotalEnergy implements the api.MeterEnergy interface | ||
| func (m *HoymilesDTUModbusTcp) TotalEnergy() (float64, error) { | ||
| res, err := m.valuesG() | ||
| return res.totalEnergy / 1e3, err // Wh to kWh | ||
| } | ||
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,39 @@ | ||
| template: hoymiles-dtu-mb | ||
| products: | ||
| - brand: Hoymiles | ||
| description: | ||
| de: "HMT/HMS-Serie mit DTU PRO S / MODBUS TCP" | ||
| en: "HMT/HMS-Series with DTU PRO S / MODBUS TCP" | ||
| requirements: | ||
| description: | ||
| de: | | ||
| Benötigt wird ein Hoymiles Wechselrichter der HMT/HMS Serie mit DTU PRO S datalogger mit Modbus TCP aktiviert (verbunden mit LAN) | ||
| en: | | ||
| Requires a Hoymiles Inverter of the HMT/HMS Series with DTU PRO S datalogger with Modbus TCP enabled (connected with LAN) | ||
| params: | ||
| - name: usage | ||
| choice: ["pv"] | ||
| - name: host | ||
| help: | ||
| de: "IP-Adresse des DTU PRO S" | ||
| en: "IP address of the DTU PRO S" | ||
| - name: port | ||
| advanced: true | ||
| default: "502" | ||
| help: | ||
| de: "Port des Modbus TCP Servers (Standard: 502)" | ||
| en: "Port of the Modbus TCP Server (default: 502)" | ||
| - name: maxacpower | ||
| advanced: true | ||
| default: "0" | ||
| description: | ||
| de: "Gesamtleistung der Wechselrichter" | ||
| en: "Total maximum power of the inverters" | ||
| help: | ||
| de: "Gesamtleistung der Wechselrichter in Watt (z.B. 3000)" | ||
| en: "Total maximum power of the inverters in watt (e.g. 3000)" | ||
| render: | | ||
| type: hoymiles-dtu-mb | ||
| host: {{ .host }} | ||
| port: {{ .port }} | ||
| maxacpower: {{ .maxacpower }} |
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!
There was an error while loading. Please reload this page.