141 changes: 141 additions & 0 deletions meter/hoymiles-dtu-mbtcp.go
Original file line number Diff line number Diff line change
@@ -0,0 +1,141 @@
package meter

import (
"context"
"encoding/binary"
"fmt"
"net"
"time"

"github.com/evcc-io/evcc/api"
"github.com/evcc-io/evcc/util"
"github.com/evcc-io/evcc/util/modbus"
)

func init() {
registry.Add("hoymiles-dtu-mb", NewHoymilesDTUModbusTcpFromConfig)
}

type HoymilesDTUModbusTcpConfig struct {
Host string
Port string
ID uint8
MaxACPower int
Cache time.Duration
}

type hoymilesDTUValues struct {
power float64
totalEnergy float64
}

type HoymilesDTUModbusTcp struct {
log *util.Logger
conn *modbus.Connection
maxAC float64
valuesG func() (hoymilesDTUValues, error)
}

// NewHoymilesDTUModbusTcpFromConfig creates a Hoymiles DTU meter from generic config
func NewHoymilesDTUModbusTcpFromConfig(other map[string]any) (api.Meter, error) {
cc := HoymilesDTUModbusTcpConfig{
Port: "502",
ID: 1,
Cache: time.Second * 15,
// cache results for 15 seconds to avoid hitting the DTU too often
}

if err := util.DecodeOther(other, &cc); err != nil {
return nil, err
}

uri := net.JoinHostPort(cc.Host, cc.Port)

modbus.Lock()
defer modbus.Unlock()

conn, err := modbus.NewConnection(context.Background(), uri, "", "", 0, modbus.Tcp, cc.ID)
if err != nil {
return nil, err
}

res := &HoymilesDTUModbusTcp{
log: util.NewLogger("hoymiles-dtu-mb"),
conn: conn,
maxAC: float64(cc.MaxACPower),
}

res.valuesG = util.Cached(res.readCurrentValues, cc.Cache)

maxACPower := pvMaxACPower{MaxACPower: float64(cc.MaxACPower)}
return decorateMeter(res, res.TotalEnergy, nil, nil, nil, maxACPower.Decorator()), nil
}

var _ api.Meter = (*HoymilesDTUModbusTcp)(nil)

// Function to read single panel power from the DTU
// param panelIndex: the index of the panel to read (starting from 0),
// and modbus session, and returns the power in watts, or an error if the read fails
// returns the power in watts, totalCumulativeProduction in Wh, a flag indicating whether a panel exists, or an error if the read fails
func (m *HoymilesDTUModbusTcp) PanelPower(panelIndex int) (float64, float64, bool, error) {
PORT_LENGTH := uint16(0x28) // length of the data for each panel in bytes
START_REGISTER := uint16(0x1000) // starting register for the first panel
// calculate the starting register for the panel based on the index
startRegister := START_REGISTER + uint16(panelIndex)*PORT_LENGTH
// read PORT_LENGTH bytes from the DTU starting at startRegister
results, err := m.conn.ReadHoldingRegisters(startRegister, PORT_LENGTH)
Comment thread
sourcery-ai[bot] marked this conversation as resolved.
Outdated
if err != nil {
return 0, 0, false, fmt.Errorf("Failed to read hoymiles-dtu panel %d: %w", panelIndex, err)
}
// check that results has at least 24 bytes (to read power and total cumulative production)
if len(results) < 24 {
return 0, 0, false, fmt.Errorf("Invalid response length for panel %d: expected at least 24 bytes, got %d", panelIndex, len(results))
}

// inverterSerial in 0x1 – 0x6, hex to string
serialBytes := results[1:6]
inverterSerial := fmt.Sprintf("%X", serialBytes)
serialIsZero := binary.BigEndian.Uint32(serialBytes[:4]) == 0 && serialBytes[4] == 0
// portNumber in 0x7, hex to int
portNumber := int(results[7])
if serialIsZero || portNumber == 0 {
m.log.TRACE.Printf("Panel %d: No more panels to read", panelIndex)
// if the serial number is all zeros or the port number is zero, we assume there are no more panels to read
return 0, 0, false, nil
}
// power in 0x10 – 0x11, hex to uint16, divided by 10 to get actual power in watts (one decimal place precision)
power := float64(binary.BigEndian.Uint16(results[16:18])) / 10.0
// totalCumulativeProduction in bytes 0x14 – 0x17, hex to uint32, in Wh
totalCumulativeProduction := binary.BigEndian.Uint32(results[20:24]) // in Wh
m.log.TRACE.Printf("Panel %d: Inverter Serial: %s, Port Number: %d, Power: %.1f W, Total Cumulative Production: %d Wh", panelIndex, inverterSerial, portNumber, power, totalCumulativeProduction)
return power, float64(totalCumulativeProduction), true, nil
}

func (m *HoymilesDTUModbusTcp) readCurrentValues() (hoymilesDTUValues, error) {
var values hoymilesDTUValues
for i := 0; i < 99; i++ {
Comment thread
sourcery-ai[bot] marked this conversation as resolved.
Outdated
power, cumulative, found, err := m.PanelPower(i)
if err != nil {
return hoymilesDTUValues{}, fmt.Errorf("Failed to read hoymiles-dtu-panel %d: %w", i, err)
}
if !found {
break
}
values.power += power
values.totalEnergy += cumulative
}
m.log.DEBUG.Printf("Total power from all panels: %.2f W / %.2f W, Total cumulative production: %.2f Wh", values.power, m.maxAC, values.totalEnergy)
return values, nil
}

// CurrentPower implements the api.Meter interface
func (m *HoymilesDTUModbusTcp) CurrentPower() (float64, error) {
res, err := m.valuesG()
return res.power, err
}

// TotalEnergy implements the api.MeterEnergy interface
func (m *HoymilesDTUModbusTcp) TotalEnergy() (float64, error) {
res, err := m.valuesG()
return res.totalEnergy / 1e3, err // Wh to kWh
}
39 changes: 39 additions & 0 deletions templates/definition/meter/hoymiles-dtu-mb.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,39 @@
template: hoymiles-dtu-mb
products:
- brand: Hoymiles
description:
de: "HMT/HMS-Serie mit DTU PRO S / MODBUS TCP"
en: "HMT/HMS-Series with DTU PRO S / MODBUS TCP"
requirements:
description:
de: |
Benötigt wird ein Hoymiles Wechselrichter der HMT/HMS Serie mit DTU PRO S datalogger mit Modbus TCP aktiviert (verbunden mit LAN)
en: |
Requires a Hoymiles Inverter of the HMT/HMS Series with DTU PRO S datalogger with Modbus TCP enabled (connected with LAN)
params:
- name: usage
choice: ["pv"]
- name: host
help:
de: "IP-Adresse des DTU PRO S"
en: "IP address of the DTU PRO S"
- name: port
advanced: true
default: "502"
help:
de: "Port des Modbus TCP Servers (Standard: 502)"
en: "Port of the Modbus TCP Server (default: 502)"
- name: maxacpower
advanced: true
default: "0"
description:
de: "Gesamtleistung der Wechselrichter"
en: "Total maximum power of the inverters"
help:
de: "Gesamtleistung der Wechselrichter in Watt (z.B. 3000)"
en: "Total maximum power of the inverters in watt (e.g. 3000)"
render: |
type: hoymiles-dtu-mb
host: {{ .host }}
port: {{ .port }}
maxacpower: {{ .maxacpower }}
Loading