Skip to content

Commit 156f131

Browse files
committed
Merge remote-tracking branch 'github/master'
2 parents d018db4 + 13b4f26 commit 156f131

File tree

9 files changed

+103
-94
lines changed

9 files changed

+103
-94
lines changed

Manuals/Bibliography/FDS_general.bib

Lines changed: 14 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -6257,11 +6257,23 @@ @TECHREPORT{Sung:TN2019
62576257
}
62586258

62596259
@TECHREPORT{Sung:TN2021,
6260-
author = {K. Sung and A. Hamins},
6260+
author = {K. Sung and R. Falkenstein-Smith and A. Hamins},
62616261
title = {{Velocity and Temperature Structure of Medium-Scale Pool Fires}},
62626262
institution = {National Institute of Standards and Technology},
62636263
year = {2021},
6264-
number = {in preparation},
6264+
month = {June},
6265+
number = {2162},
6266+
type = {NIST Technical Note},
6267+
address = {Gaithersburg, Maryland}
6268+
}
6269+
6270+
@TECHREPORT{Sung:TN2162r1,
6271+
author = {K. Sung and R. Falkenstein-Smith and M. Bundy and M. Fernandez and A. Hamins},
6272+
title = {{The Global and Local Structure of Medium-Scale Pool Fires}},
6273+
institution = {National Institute of Standards and Technology},
6274+
year = {2024},
6275+
month = {October},
6276+
number = {2162r1},
62656277
type = {NIST Technical Note},
62666278
address = {Gaithersburg, Maryland}
62676279
}

Manuals/FDS_Validation_Guide/Experiment_Chapter.tex

Lines changed: 5 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -2148,24 +2148,24 @@ \section{NIST Polymers}
21482148
\section{NIST Pool Fire Experiments}
21492149
\label{NIST_Pool_Fires_Description}
21502150

2151-
The NIST Pool Fire Experiments include temperature, species concentration, velocity, and heat flux measurements of 30~cm and 100~cm diameter circular liquid fuel fires, and 37~cm gaseous burner fires.
2151+
The NIST Pool Fire Experiments include temperature, species concentration, velocity, and heat flux measurements of 30~cm and 100~cm diameter circular liquid fuel fires, and 37~cm gaseous burner fires. The 30~cm and 37~cm fires are documented in Ref.~\cite{Sung:TN2162r1}.
21522152

21532153
The 30~cm burner is 15~cm deep and has a wall thickness of 1.6~mm. The burner is fitted with legs such that the burner rim is positioned 30~cm above the floor. The bottom of the burner is maintained at a constant temperature by flowing tap water (nominally 20~$^\circ$C) through a 3~cm section on the bottom of the fuel pan. The dimensions of the circular burner are similar to Weckman's methanol experiment described in Sec.~\ref{Waterloo_Methanol_Description}.
21542154

2155-
The 100~cm burner is also 15~cm deep, has a wall thickness of 1.6~mm, and is water-cooled.
2155+
The 37~cm burner is actually 38~cm in diameter with an effective diameter of 37~cm. It is water cooled, and the surface temperature is maintained at approximately 40~$^\circ$C. The measured fuel flow rate for the methane fire was 0.69~g/s and its estimated HRR was 34.5~kW. The heat release rates of the three propane fires were 20~kW, 34~kW, and 50~kW.
21562156

2157-
The 37~cm burner is actually 38~cm in diameter with an effective diameter of 37~cm. It is water cooled, and the surface temperature is maintained at approximately 40~$^\circ$C. The measured fuel flow rate for the methane fire was 0.69~g/s and its estimated HRR was 34.5~kW. The heat release rates of the two propane fires were 20~kW and 34~kW.
2157+
The 100~cm burner is also 15~cm deep, has a wall thickness of 1.6~mm, and is water-cooled.
21582158

21592159
Details and references with regard to the plume temperature measurements are given in Sec.~\ref{NIST_Pool_Fires_Plume_Temps}. Details on the heat flux measurements are given in Sec.~\ref{NIST_Pool_Fires_Heat_Flux_Results}. Details on the gas species measurements is given in Sec.~\ref{sec:NIST_Pool_Fires}. Details on the velocity measurements is given in Sec.~\ref{NIST_Pool_Fires_Velocity}.
21602160

21612161

21622162
\subsubsection{Modeling Notes}
21632163

2164-
The 30~cm pool fires are modeled at three different grid resolutions---2~cm, 1~cm, and 0.5~cm. The 100~cm pool fires are modeled at 4~cm, 2~cm, and 1~cm resolution. The mass loss rate of the fuel is specified.
2164+
The 30~cm and 37~cm fires are modeled at three different grid resolutions---2~cm, 1~cm, and 0.5~cm. The 100~cm methanol pool fire is modeled at 4~cm, 2~cm, and 1~cm resolution. The mass loss rate of the fuel is specified for the 30~cm and 37~cm fires, and both predicted and specified for the 100~cm fire.
21652165

21662166
A two-step reaction mechanism is implemented. In the first reaction, fuel is converted to CO, soot, H$_2$, and H$_2$O. In the second reaction, the CO, soot, and H$_2$ are converted to CO$_2$ and H$_2$O. Both reactions employ fast kinetics, but proceed in series, not in parallel. The relative amounts of CO, soot, and H$_2$ produced in the first step are still subjects of study, and for the moment have been estimated based on measured results. The fractions of carbon atoms converted to CO in the first step are as follows---0.85 for acetone; 0.95 for ethanol; 0.97 for methane; 1.0 for methanol; 0.85 for propane. For all fuels, one half of the hydrogen atoms are converted to H$_2$ in the first step.
21672167

2168-
The radiative fractions are specified based on measured values---0.31 for acetone; 0.26 for ethanol; 0.15 for methane; 0.21 for 1~m methanol; 0.22 for 30~cm methanol; 0.22 for propane.
2168+
The radiative fractions are specified based on reported values from Ref.~\cite{Sung:TN2162r1}---0.31 for acetone; 0.26 for ethanol; 0.35 for heptane; 0.21 for methane; 0.21 for 1~m methanol; 0.23 for 30~cm methanol; 0.23, 0.30, and 0.33 for the 20~kW, 34~kW, and 50~kW propane fires, respectively.
21692169

21702170

21712171
\section{NIST Smoke Alarm Experiments}

Manuals/FDS_Validation_Guide/Plume_Chapter.tex

Lines changed: 14 additions & 11 deletions
Original file line numberDiff line numberDiff line change
@@ -214,8 +214,8 @@ \subsection{NIST Pool Fires}
214214

215215
Details of the NIST Pool Fires experiments and modeling are found in Sec.~\ref{NIST_Pool_Fires_Description}. On the following pages are comparisons of predicted and measured temperatures at various locations in and around liquid and gaseous pool fires.
216216
\begin{itemize}
217-
\item Figures~\ref{NIST_Pool_Fires_Temperature_1} and \ref{NIST_Pool_Fires_Temperature_2} display centerline profiles of mean and rms temperature for 30~cm diameter acetone, ethanol, and methanol liquid pool fires; and 37~cm methane and propane gaseous fires~\cite{Falkenstein-Smith:2019}.
218-
\item Figure~\ref{NIST_Pool_Fires_Temperature_3} displays radial profiles of mean and rms temperature for a 30~cm methanol fire at heights of $z=3$~cm (mean only), $z=30$~cm (mean only), $z=41$~cm, $z=51$~cm, and $z=61$~cm. The profiles at 3~cm and 30~cm are from Ref.~\cite{Hamins:TN1928} and the others are from Ref.~\cite{Sung:TN2021}.
217+
\item Figures~\ref{NIST_Pool_Fires_Temperature_1} and \ref{NIST_Pool_Fires_Temperature_2} display centerline profiles of mean and rms temperature for 30~cm diameter acetone, ethanol, heptane, and methanol liquid pool fires; and 37~cm methane and propane gaseous fires~\cite{Sung:TN2162r1}.
218+
\item Figure~\ref{NIST_Pool_Fires_Temperature_3} displays radial profiles of mean and rms temperature for a 30~cm methanol fire at heights of $z=3$~cm (mean only), $z=30$~cm (mean only), $z=41$~cm, $z=51$~cm, and $z=61$~cm. The profiles at 3~cm and 30~cm are from Ref.~\cite{Hamins:TN1928} and the others are from Ref.~\cite{Sung:TN2162r1}.
219219
\item Figures~\ref{NIST_Pool_Fires_Plume_Temps_1} and \ref{NIST_Pool_Fires_Plume_Temps_2} display centerline and radial profiles of mean and rms temperature for a 100~cm methanol fire. The radial profiles are located at heights of $z=20$~cm, $z=60$~cm, $z=100$~cm, $z=140$~cm, and $z=180$~cm~\cite{Sung:TN2019}.
220220
\end{itemize}
221221

@@ -227,25 +227,28 @@ \subsection{NIST Pool Fires}
227227
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Acetone_T_CL_RMS} \\
228228
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Ethanol_T_CL} &
229229
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Ethanol_T_CL_RMS} \\
230-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_T_CL} &
231-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_T_CL_RMS}
230+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Heptane_T_CL} &
231+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Heptane_T_CL_RMS} \\
232+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methanol_T_CL} &
233+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methanol_T_CL_RMS}
232234
\end{tabular*}
233-
\caption[NIST Pool Fires, centerline temperature, acetone, ethanol, methane]
234-
{NIST Pool Fires, centerline temperature profiles, 30~cm acetone, 30~cm ethanol, 37~cm methane.}
235+
\caption[NIST Pool Fires, centerline temperature, acetone, ethanol, heptane, methanol]{NIST Pool Fires, centerline temperature profiles, 30~cm pan, acetone, ethanol, heptane, and methanol.}
235236
\label{NIST_Pool_Fires_Temperature_1}
236237
\end{figure}
237238

238239
\begin{figure}[p]
239240
\begin{tabular*}{\textwidth}{l@{\extracolsep{\fill}}r}
240-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methanol_T_CL} &
241-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methanol_T_CL_RMS} \\
241+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_T_CL} &
242+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_T_CL_RMS} \\
242243
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_20kW_T_CL} &
243244
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_20kW_T_CL_RMS} \\
244245
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_34kW_T_CL} &
245-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_34kW_T_CL_RMS}
246+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_34kW_T_CL_RMS} \\
247+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_T_CL} &
248+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_T_CL_RMS}
246249
\end{tabular*}
247-
\caption[NIST Pool Fires, centerline temperature, methanol and propane]
248-
{NIST Pool Fires, centerline temperature profiles, 30~cm methanol and 37~cm propane.}
250+
\caption[NIST Pool Fires, centerline temperature, 37~cm pan, methane and propane]
251+
{NIST Pool Fires, centerline temperature profiles, 37~cm pan, methane and propane.}
249252
\label{NIST_Pool_Fires_Temperature_2}
250253
\end{figure}
251254

Manuals/FDS_Validation_Guide/Species_Chapter.tex

Lines changed: 16 additions & 29 deletions
Original file line numberDiff line numberDiff line change
@@ -1874,37 +1874,24 @@ \subsection{NIST Pool Fires}
18741874
\caption[NIST Pool Fires, centerline product species, propane, 34 kW]{NIST Pool Fires, centerline product species, propane, 34 kW.}
18751875
\label{NIST_Pool_Fires_Propane_34kW}
18761876
\end{figure}
1877+
1878+
\begin{figure}[p]
1879+
\begin{tabular*}{\textwidth}{l@{\extracolsep{\fill}}r}
1880+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_O2_CL} &
1881+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_Fuel_CL} \\
1882+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_CO2_CL} &
1883+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_CO_CL} \\
1884+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_H2O_CL} &
1885+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_H2_CL} \\
1886+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_N2_CL} &
1887+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_Soot_CL}
1888+
\end{tabular*}
1889+
\caption[NIST Pool Fires, centerline product species, propane, 50 kW]{NIST Pool Fires, centerline product species, propane, 50 kW.}
1890+
\label{NIST_Pool_Fires_Propane_50kW}
1891+
\end{figure}
1892+
18771893
\clearpage
18781894

1879-
%\subsection{PRISME DOOR Experiments}
1880-
%
1881-
%Each compartment in the PRISME DOOR experiments contained carbon monoxide measurements in the upper (haut) and lower (bas) layers.
1882-
%
1883-
%\begin{figure}[!ht]
1884-
%\begin{tabular*}{\textwidth}{l@{\extracolsep{\fill}}r}
1885-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D1_Room_1_CO} &
1886-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D2_Room_1_CO} \\
1887-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D3_Room_1_CO} &
1888-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D4_Room_1_CO} \\
1889-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D5_Room_1_CO} &
1890-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D6_Room_1_CO}
1891-
%\end{tabular*}
1892-
%\label{PRISME_CO_1}
1893-
%\end{figure}
1894-
%
1895-
%\begin{figure}[p]
1896-
%\begin{tabular*}{\textwidth}{l@{\extracolsep{\fill}}r}
1897-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D1_Room_2_CO} &
1898-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D2_Room_2_CO} \\
1899-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D3_Room_2_CO} &
1900-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D4_Room_2_CO} \\
1901-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D5_Room_2_CO} &
1902-
%\includegraphics[height=2.15in]{SCRIPT_FIGURES/PRISME/PRS_D6_Room_2_CO}
1903-
%\end{tabular*}
1904-
%\label{PRISME_CO_2}
1905-
%\end{figure}
1906-
%
1907-
%\clearpage
19081895

19091896
\subsection{Summary, Products of Incomplete Combustion}
19101897
\label{Carbon Monoxide Concentration}

Manuals/FDS_Validation_Guide/Velocity_Chapter.tex

Lines changed: 8 additions & 38 deletions
Original file line numberDiff line numberDiff line change
@@ -306,50 +306,20 @@ \section{McCaffrey's Plume Correlation}
306306
\section{NIST Pool Fires}
307307
\label{NIST_Pool_Fires_Velocity}
308308

309-
% THE CL RMS VELOCITIES ARE CURRENTLY UNDER INVESTIGATTION...
310-
311-
% Figures~\ref{NIST_Pool_Fires_Velocity_1} and \ref{NIST_Pool_Fires_Velocity_2} display centerline profiles of mean and rms vertical velocity for 30~cm acetone, ethanol, and methanol pool fires; and 37~cm methane and propane gas burners~\cite{Sung:TN2021}.
312-
313-
% \begin{figure}[!h]
314-
% \begin{tabular*}{\textwidth}{l@{\extracolsep{\fill}}r}
315-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Acetone_w_CL} &
316-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Acetone_w_CL_RMS} \\
317-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Ethanol_w_CL} &
318-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Ethanol_w_CL_RMS} \\
319-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_w_CL} &
320-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_w_CL_RMS}
321-
% \end{tabular*}
322-
% \caption[NIST Pool Fires, centerline velocity]{NIST Pool Fires, centerline profiles of mean and rms vertical velocity for 30~cm acetone and ethanol liquid pool fires; and a 37~cm methane gaseous fire.}
323-
% \label{NIST_Pool_Fires_Velocity_1}
324-
% \end{figure}
325-
326-
% \newpage
327-
328-
% \begin{figure}[p]
329-
% \begin{tabular*}{\textwidth}{l@{\extracolsep{\fill}}r}
330-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methanol_w_CL} &
331-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methanol_w_CL_RMS} \\
332-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_20kW_w_CL} &
333-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_20kW_w_CL_RMS} \\
334-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_34kW_w_CL} &
335-
% \includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_34kW_w_CL_RMS}
336-
% \end{tabular*}
337-
% \caption[NIST Pool Fires, centerline velocity]{NIST Pool Fires, centerline profiles of mean and rms vertical velocity for a 30~cm methanol fire; and 37~cm propane fires of 20~kW and 34~kW.}
338-
% \label{NIST_Pool_Fires_Velocity_2}
339-
% \end{figure}
340-
341-
Figure~\ref{NIST_Pool_Fires_Velocity_1} displays centerline profiles of mean vertical velocity for 30~cm acetone, ethanol, and methanol pool fires; and 37~cm methane and propane gas burners~\cite{Sung:TN2021}.
309+
Figure~\ref{NIST_Pool_Fires_Velocity_1} displays centerline profiles of mean vertical velocity for 30~cm acetone, ethanol, heptane, and methanol pool fires; and 37~cm methane and propane gas burners~\cite{Sung:TN2162r1}.
342310

343311
\begin{figure}[!h]
344312
\begin{tabular*}{\textwidth}{l@{\extracolsep{\fill}}r}
345313
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Acetone_w_CL} &
314+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Ethanol_w_CL} \\
315+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Heptane_w_CL} &
346316
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methanol_w_CL} \\
347-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Ethanol_w_CL} &
348-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_w_CL} \\
349-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_20kW_w_CL} &
350-
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_34kW_w_CL}
317+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Methane_w_CL} &
318+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_20kW_w_CL} \\
319+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_34kW_w_CL} &
320+
\includegraphics[height=2.15in]{SCRIPT_FIGURES/NIST_Pool_Fires/NIST_Propane_50kW_w_CL}
351321
\end{tabular*}
352-
\caption[NIST Pool Fires, centerline velocity]{NIST Pool Fires, centerline profiles of mean vertical velocity for 30~cm acetone, methanol, and ethanol liquid pool fires, a 37~cm methane fire, and propane fires of 20~kW and 34~kW.}
322+
\caption[NIST Pool Fires, centerline velocity]{NIST Pool Fires, centerline profiles of mean vertical velocity for 30~cm acetone, ethanol, heptane, and methanol liquid pool fires, a 37~cm methane fire, and propane fires of 20~kW, 34~kW, and 50~kW.}
353323
\label{NIST_Pool_Fires_Velocity_1}
354324
\end{figure}
355325

0 commit comments

Comments
 (0)