Skip to content

Conversation

@mar0x
Copy link

@mar0x mar0x commented Apr 15, 2022

After successful probe (G38.2 Z-20 F100) step control is blocked by STEP_CONTROL_END_MOTION flag. It blocks stepper prepare buffer and after jog action ($J=G91Z1F10) it is immediately turns to Idle and then to Run state. Although stepper actions are correct it is impossible to stop this jog action (see Candle #542 ).

[fix] After successful probe (G38.2 Z-20 F100) step control
is blocked by STEP_CONTROL_END_MOTION flag. It blocks stepper prepare buffer
and after jog action ($J=G91Z1F10) it is immediately turns to Idle and then
to Run state. Although stepper actions are correct it is impossible to stop
this jog action (see [Candle gnea#542](Denvi/Candle#542) ).
@mar0x
Copy link
Author

mar0x commented Jun 11, 2022

Please confirm the jog action is incorrect after probe or advise proper command sequence to enable jog stop after probe (see Candle #542 ).

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant