Notifications
You must be signed in to change notification settings - Fork 103
HydraFW binary raw wire mode guide
This guide is updated towards firmware release HydraFW v0.8 Beta and later
This mode allows to control 2-Wire and 3-Wire (called raw-wire)
- 2-Wire pins: CLK=PB3, IO=PB4
- For more details see https://github.com/hydrabus/hydrafw/wiki/HydraFW-2wire-guide
- 3-Wire pins: CLK=PB3, SDI=PB4, SDO=PB5
- For more details see https://github.com/hydrabus/hydrafw/wiki/HydraFW-3wire-guide
Once the raw-wire mode has been selected, the following commands are available :
-
0b00000000Return to main mode. ReturnsBBIO1 -
0b00000001Mode identification. ReturnsRAW1 -
0b00000110Read byte -
0b00000111Read bit -
0b00001000Peek input pin -
0b00001001Clock tick -
0b0000101xClock low(0) / high(1) -
0b0000110xData low(0) / high(1) -
0b0001xxxxBulk raw-wire transfer -
0b0010xxxxBulk clock ticks -
0b0011xxxxBulk send bits -
0b01000000Configure peripherals -
0b011000xxSet raw-wire speed -
0b10000xy0Configure raw-wire port -
0b11xxxxxxBinary Auxiliary pins
This command ready a byte on the raw-wire bus, and sends it back to the user.
This command will send a clock pulse, then return the value of the data line to the user.
This command returns the state of the data line.
This command sends a clock pulse on the CLK line. Returns 0x01 once done.
This commands sets the CLK line low(0) or high(1). Returns 0x01 once done.
This commands sets the data line low(0) or high(1). Returns 0x01 once done.
In this mode, the last 4 bits of the command define the number of bytes to write (from 1 to 16) (Command 0b00010000 will send 1 byte). Hydrabus will wait for the defined number of bytes, then send a 0x01 (acknowledge).
In this mode, the last 4 bits of the command define the number of clock ticks to send (from 1 to 16) (Command 0b00100000 will send 1 clock tick). Returns 0x01 once done.
In this mode, the last 4 bits of the command define the number of bits to send (from 1 to 16) (Command 0b00110000 will send 1 bit). Returns 0x01 once done.
Do nothing (to be defined for future evolution).
Returns 0x01.
This command sets the raw-wire device bitrate. The two last bits will select the speed (int bits/sec) within the following list :
-
0b00=> 5000 -
0b01=> 50000 -
0b10=> 100000 -
0b11=> 1000000
This commands returns 0x01 if successful, 0x00 in case of error.
This allows to set the following parameters :
-
wsets the pin output (0=open drain, 1=push-pull) -
xsets the mode (0=2-wire, 1=3-wire) -
ysets the endianness (0=MSB, 1=LSB) -
zsets the clock polarity (0=idle low, 1=idle high)
This commands returns 0x01 if successful, 0x00 in case of error.
- CHANGELOG
- Console commands
- Binary mode guide
-
NFC/HydraNFC v1 guide
- Read UID of an ISO/IEC_14443 Tag
- Read UID and data of a MIFARE Ultralight Tag
- Read UID of an ISO/IEC 15693 Tag
- Emul ISO14443a Tag
- Emul MIFARE Ultralight Tag
- Emul Mifare Classic Tag
- Unique NFC sniffer design
- Launch NFC sniffer from console
- Sniffer ISO14443A wireshark pcap
- Autonomous/stand-alone sniffer mode
- Sniffer ISO14443A real-time infinite trace mode
- HydraFW-HydraNFC-v1.x-TRF7970A-Tutorial