2 changes: 1 addition & 1 deletion .travis.yml
Original file line number Diff line number Diff line change
Expand Up @@ -32,7 +32,7 @@ env:
global:
- DOCKER_REPONAME=lbnlblum
- BUILDINGSPY_VERSION=BuildingsPy@v5.2.0
- OMC_VERSION=ubuntu-2204-omc:1.24.0-1
- OMC_VERSION=ubuntu-2404-omc:1.26.3-1
- OPTIMICA_VERSION=travis-ubuntu-2404-optimica:1.66
- DYMOLA_VERSION=travis_ubuntu-2004_dymola:2024xRefresh1-x86_64
- ENERGYPLUS_9_6_0=EnergyPlus-9.6.0-f420c06a69-Linux-Ubuntu20.04-x86_64
Expand Down
80 changes: 62 additions & 18 deletions Buildings/Resources/Scripts/BuildingsPy/conf.yml
Original file line number Diff line number Diff line change
@@ -1,3 +1,7 @@
- model_name: Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Winter
openmodelica:
comment: 'TimeoutExpired: omc timed out after 300 seconds'
time_out: 600
- model_name: Buildings.Airflow.Multizone.Examples.PressurizationData
optimica:
comment: High solver tolerance required to avoid time out.
Expand Down Expand Up @@ -27,26 +31,33 @@
simulate: false
- model_name: Buildings.DHC.Examples.Cooling.ElectricChillersDirectETS
openmodelica:
comment: simulation terminated by an assertion at initialization
simulate: false
comment: translation failed on travis
translate: false
optimica:
comment: 'FMUException: Failed to update the events at time: 1.578082E+07.'
simulate: false
- model_name: Buildings.DHC.Examples.Steam.SingleBoiler
openmodelica:
comment: Timeout after 600 s
simulate: false
- model_name: Buildings.DHC.Loads.BaseClasses.Examples.CouplingTimeSeries
openmodelica:
comment: 'simulation terminated by an assertion at initialization, Invalid root: (0)^(-1.5), corrected in OMC 1.23.0~dev-206-g00d3636'
comment: 'simulation terminated by an assertion at initialization, Invalid root:
(0)^(-1.5), corrected in OMC 1.23.0~dev-206-g00d3636'
simulate: false
- model_name: Buildings.DHC.Loads.BaseClasses.Examples.CouplingTimeSeriesSingleLoop
openmodelica:
comment: simulation terminated by an assertion at initialization
simulate: false
- model_name: Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution2
openmodelica:
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution2_translate.mos'']'' returned non-zero exit status 2.'
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.DHC.Loads.BaseClasses.Validation.BenchmarkFlowDistribution2_translate.mos'']''
returned non-zero exit status 2.'
translate: false
- model_name: Buildings.DHC.Loads.BaseClasses.Validation.FlowDistributionPumpControl
openmodelica:
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.DHC.Loads.BaseClasses.Validation.FlowDistributionPumpControl_translate.mos'']'' returned non-zero exit status 2.'
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.DHC.Loads.BaseClasses.Validation.FlowDistributionPumpControl_translate.mos'']''
returned non-zero exit status 2.'
translate: false
- model_name: Buildings.DHC.Loads.Combined.Examples.BuildingTimeSeriesWithETS
openmodelica:
Expand All @@ -66,11 +77,12 @@
simulate: false
- model_name: Buildings.DHC.Networks.Examples.Distribution1PipeExample
openmodelica:
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.DHC.Networks.Examples.Distribution1PipeExample_translate.mos'']'' returned non-zero exit status 2.'
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.DHC.Networks.Examples.Distribution1PipeExample_translate.mos'']''
returned non-zero exit status 2.'
translate: false
- model_name: Buildings.DHC.Networks.Examples.Distribution2PipeExample
openmodelica:
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.DHC.Networks.Examples.Distribution2PipeExample_translate.mos'']'' returned non-zero exit status 2.'
comment: translation fails
translate: false
- model_name: Buildings.DHC.Plants.Combined.Examples.AllElectricCWStorage
dymola:
Expand All @@ -80,6 +92,10 @@
simulate: false
optimica:
time_out: 900
- model_name: Buildings.DHC.Plants.Combined.Subsystems.Validation.ChillerHeatRecoveryGroup
openmodelica:
comment: simulation terminated by an assertion at initialization.
simulate: false
- model_name: Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage
optimica:
time_out: 600
Expand Down Expand Up @@ -131,8 +147,14 @@
comment: Times out after 900 seconds.
time_out: 900
optimica:
comment: Fails with 'The rootfinding function failed in an unrecoverable manner.' Since oct-r26446
comment: Fails with 'The rootfinding function failed in an unrecoverable manner.'
Since oct-r26446
simulate: false
- model_name: Buildings.Examples.VAVReheat.ASHRAE2006
openmodelica:
comment: 'TimeoutExpired: Command ''[''omc'', ''Buildings.Examples.VAVReheat.ASHRAE2006_simulate.mos'']''
timed out after 300 seconds'
time_out: 600
- model_name: Buildings.Examples.VAVReheat.Guideline36
openmodelica:
comment: Timeout during translation
Expand Down Expand Up @@ -171,6 +193,16 @@
openmodelica:
comment: timed out after 300 seconds
simulate: false
- model_name: Buildings.Fluid.FixedResistances.BuriedPipes.Examples.SingleBuriedPipe
openmodelica:
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.Fluid.FixedResistances.BuriedPipes.Examples.SingleBuriedPipe_simulate.mos'']''
returned non-zero exit status 255.'
simulate: false
- model_name: Buildings.Fluid.FixedResistances.BuriedPipes.Examples.TwoBuriedPipes
openmodelica:
comment: 'CalledProcessError: Command ''[''omc'', ''Buildings.Fluid.FixedResistances.BuriedPipes.Examples.TwoBuriedPipes_simulate.mos'']''
returned non-zero exit status 255.'
simulate: false
- model_name: Buildings.Fluid.FixedResistances.BuriedPipes.Examples.TwoPipesConduit
openmodelica:
comment: Assertion due to what looks like wrong results, see https://github.com/lbl-srg/modelica-buildings/issues/3687
Expand All @@ -195,36 +227,45 @@
optimica:
comment: Timeout after 300 s
time_out: 600
- model_name: Buildings.Fluid.HeatExchangers.Radiators.Examples.RadiatorEN442_2
openmodelica:
comment: Translation failed. See https://github.com/OpenModelica/OpenModelica/issues/14791
translate: false
- model_name: Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator
openmodelica:
comment: simulation terminated by an assertion at initialization.
simulate: false
- model_name: Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingMixing
openmodelica:
comment: Timeout after 600 s on travis, https://app.travis-ci.com/github/lbl-srg/modelica-buildings/jobs/600714398#L489
comment: Timeout after 300 s. See also OpenModelica, issue 13341
simulate: false
optimica:
comment: 'CVodeError: ''The rootfinding function failed in an unrecoverable manner. At time 32392.196613.'''
comment: 'CVodeError: ''The rootfinding function failed in an unrecoverable manner.
At time 32392.196613.'''
simulate: false
- model_name: Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DiversionOpenLoop
optimica:
comment: 'The following equation(s) could not be matched to any variable: isEna.u = loa.ctl.cha.pre_u_start, isEna.u = loa1.ctl.cha.pre_u_start'
comment: 'The following equation(s) could not be matched to any variable: isEna.u
= loa.ctl.cha.pre_u_start, isEna.u = loa1.ctl.cha.pre_u_start'
translate: false
- model_name: Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayCheckValve
openmodelica:
comment: 'Simulation terminated by an assert at time: 21600.1.'
simulate: false
- model_name: Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn
optimica:
comment: 'The following equation(s) could not be matched to any variable: loaOpe.mode = loaOpe.loa.ctl.cha.pre_u_start...'
comment: 'The following equation(s) could not be matched to any variable: loaOpe.mode
= loaOpe.loa.ctl.cha.pre_u_start...'
translate: false
- model_name: Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.ThrottleOpenLoop
optimica:
comment: 'The following equation(s) could not be matched to any variable: con.mode = loa.ctl.cha.pre_u_start, con.mode = loa1.ctl.cha.pre_u_start'
comment: 'The following equation(s) could not be matched to any variable: con.mode
= loa.ctl.cha.pre_u_start, con.mode = loa1.ctl.cha.pre_u_start'
translate: false
- model_name: Buildings.Fluid.HydronicConfigurations.PassiveNetworks.Examples.SingleMixingOpenLoop
optimica:
comment: 'The following equation(s) could not be matched to any variable: con.mode = loa.ctl.cha.pre_u_start, con.mode = loa1.ctl.cha.pre_u_start'
comment: 'The following equation(s) could not be matched to any variable: con.mode
= loa.ctl.cha.pre_u_start, con.mode = loa1.ctl.cha.pre_u_start'
translate: false
- model_name: Buildings.Obsolete.Examples.VAVReheat.Validation.Guideline36SteadyState
openmodelica:
Expand Down Expand Up @@ -279,15 +320,17 @@
simulate: false
- model_name: Buildings.ThermalZones.Detailed.Examples.FFD.RoomOnlyConstructionBoundary
openmodelica:
comment: Failed to copy array. Dimension sizes are not equal and destination array is not flexible.
comment: Failed to copy array. Dimension sizes are not equal and destination array
is not flexible.
simulate: false
- model_name: Buildings.ThermalZones.Detailed.Examples.FFD.RoomOnlyExteriorWallNoWindow
openmodelica:
comment: Timeout after 300 s
simulate: false
- model_name: Buildings.ThermalZones.Detailed.Examples.FFD.RoomOnlySurfaceBoundary
openmodelica:
comment: Failed to copy array. Dimension sizes are not equal and destination array is not flexible.
comment: Failed to copy array. Dimension sizes are not equal and destination array
is not flexible.
simulate: false
- model_name: Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection
dymola:
Expand Down Expand Up @@ -379,7 +422,7 @@
- model_name: Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Winter
openmodelica:
comment: Timeout on travis
time_out: 600
simulate: false
- model_name: Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSpring
openmodelica:
comment: returned non-zero exit status 255.
Expand All @@ -404,7 +447,8 @@
simulate: false
- model_name: Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase11
openmodelica:
comment: Inputs differ by more than threShold. Check output 'satisfied' for when violation(s) happened. Segmentation fault (core dumped)
comment: Inputs differ by more than threShold. Check output 'satisfied' for when
violation(s) happened. Segmentation fault (core dumped)
simulate: false
- model_name: Buildings.Utilities.IO.Python_3_8.Examples.KalmanFilter
openmodelica:
Expand Down
Loading