Far ahead of a thin-strip crack the fixed grips and the strip length leave only eps_yy nonzero, so G = M strain^2 h / 2 with M = C'_yyyy in the crack frame. strain_to_G / G_to_strain used E / (1 - nu^2) (sigma_xx = 0), which underestimates G by more than 20% for Si(110)[1-10]. Add thin_strip_modulus, thin_strip_G and thin_strip_strain; get_energy_release_rate uses ThinStripModulus and warns on the old fallback; the staging thin-strip script stores and uses the new modulus. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Problem
strain_to_G/G_to_strainconvert thin-strip strain to energy release rate withE / (1 - nu^2) is the plane-strain modulus with sigma_xx = 0. In a thin strip, though, the region far ahead of the crack is in uniaxial strain: the fixed grips and the strip's length along the crack direction pin u_x (eps_xx = 0), and the periodic front gives eps_zz = 0. The stored energy density is then M eps_yy^2 / 2 with M = C'_yyyy, the stiffness rotated into the crack frame, so
The old form underestimates G. For Si(110)[1-10] with
nu=PoissonRatio_yx(as the staging thin-strip script stores it), Stillinger-Weber gives E / (1 - nu^2) = 131.8 GPa against M = 170.4 GPa: G is about 23% too low. The strain energy of a uniaxially strained Si cell measures 170.1-170.2 GPa, confirming M. For an MH-1 fine-tuned MACE the gap is 146.5 vs 175.0 GPa.Changes
thin_strip_modulus(C, crack_direction, cleavage_plane, crack_front)returns M = C'_yyyy.thin_strip_G(strain, M, h)/thin_strip_strain(G, M, h).get_energy_release_rateusesatoms.info['ThinStripModulus']. Without it, it falls back to the old form with aUserWarning.strain_to_G/G_to_strainare kept, with a note pointing to the new functions.staging/fracture_mechanics/make_crack_thin_strip.pycomputes, stores and uses the new modulus.Not changed here:
get_stress_intensity_factorstill converts G to K with E / (1 - nu^2) usingPoissonRatio_yx, which is a separate (near-tip, anisotropic) approximation.Tests
tests/test_thin_strip.py:thin_strip_G/thin_strip_strainround-trip;get_energy_release_rateusesThinStripModulus, and warns without it.test_crack.pyandtest_cubic_crystal_crack.pystill pass.🤖 Generated with Claude Code