Problem

strain_to_G / G_to_strain convert thin-strip strain to energy release rate with

G = E / (1 - nu^2) * strain^2 * h / 2

E / (1 - nu^2) is the plane-strain modulus with sigma_xx = 0. In a thin strip, though, the region far ahead of the crack is in uniaxial strain: the fixed grips and the strip's length along the crack direction pin u_x (eps_xx = 0), and the periodic front gives eps_zz = 0. The stored energy density is then M eps_yy^2 / 2 with M = C'_yyyy, the stiffness rotated into the crack frame, so

G = M * strain^2 * h / 2

The old form underestimates G. For Si(110)[1-10] with nu = PoissonRatio_yx (as the staging thin-strip script stores it), Stillinger-Weber gives E / (1 - nu^2) = 131.8 GPa against M = 170.4 GPa: G is about 23% too low. The strain energy of a uniaxially strained Si cell measures 170.1-170.2 GPa, confirming M. For an MH-1 fine-tuned MACE the gap is 146.5 vs 175.0 GPa.

Changes

  • thin_strip_modulus(C, crack_direction, cleavage_plane, crack_front) returns M = C'_yyyy.
  • thin_strip_G(strain, M, h) / thin_strip_strain(G, M, h).
  • get_energy_release_rate uses atoms.info['ThinStripModulus']. Without it, it falls back to the old form with a UserWarning.
  • strain_to_G / G_to_strain are kept, with a note pointing to the new functions.
  • staging/fracture_mechanics/make_crack_thin_strip.py computes, stores and uses the new modulus.
  • ChangeLog entry.

Not changed here: get_stress_intensity_factor still converts G to K with E / (1 - nu^2) using PoissonRatio_yx, which is a separate (near-tip, anisotropic) approximation.

Tests

tests/test_thin_strip.py:

  • isotropic C gives lambda + 2 mu;
  • cubic (110) gives (C11 + C12)/2 + C44;
  • thin_strip_G / thin_strip_strain round-trip;
  • the strain energy of uniaxially strained SW Si matches M to 0.5% (central difference), and the old modulus is more than 20% below it;
  • get_energy_release_rate uses ThinStripModulus, and warns without it.

test_crack.py and test_cubic_crystal_crack.py still pass.

🤖 Generated with Claude Code

Far ahead of a thin-strip crack the fixed grips and the strip length leave
only eps_yy nonzero, so G = M strain^2 h / 2 with M = C'_yyyy in the crack
frame. strain_to_G / G_to_strain used E / (1 - nu^2) (sigma_xx = 0), which
underestimates G by more than 20% for Si(110)[1-10]. Add thin_strip_modulus,
thin_strip_G and thin_strip_strain; get_energy_release_rate uses
ThinStripModulus and warns on the old fallback; the staging thin-strip
script stores and uses the new modulus.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>