104 changes: 103 additions & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -327,7 +327,7 @@ For that, you need to add a `Device` node with the correct brand/model attribute

<!-- MyHome Up shutter actuator -->

<Device Brand="BTicino" Model="F418U2" SerialNumber="00A472A9">
<Device Brand="BTicino" Model="F411U2" SerialNumber="00A472A9">
<Endpoint Name="Living room/Shutter" Area="1" Point="3">
<Setting Name="Actuator type" Value="Automation" />
</Endpoint>
Expand Down Expand Up @@ -640,6 +640,108 @@ class MyEventHandler(OpenNettyEvents events) : IOpenNettyHandler
}
```

## Advanced settings

OpenNetty allows attaching specific settings to endpoints to control how events are handled or how commands are sent.
While using the default settings is generally enough, it can be useful to override them for some endpoints.

Settings can be attached programmatically or via the configuration file to devices, units or endpoints. E.g:

```xml
<Device Brand="Legrand" Model="67222" SerialNumber="487932">
<Setting Name="Action validation" Value="false" />

<Unit Id="4">
<Endpoint Name="Kitchen/Dimmable socket" />
</Unit>
</Device>
```

```csharp
options.AddEndpoint(new OpenNettyEndpoint
{
Address = OpenNettyAddress.FromNitooAddress(identifier: 487932, unit: 4),
Device = new OpenNettyDevice
{
Definition = OpenNettyDevices.GetDeviceByModel(OpenNettyBrand.Legrand, "67222")!,
Identity = new OpenNettyIdentity
{
Brand = OpenNettyBrand.Legrand,
Collection = "Céliane",
Model = "67222"
},
SerialNumber = "487932",
Settings = ImmutableDictionary.Create<OpenNettySetting, string>()
.Add(OpenNettySettings.ActionValidation, bool.FalseString)
},
Name = "Kitchen/Dimmable socket",
Protocol = OpenNettyProtocol.Nitoo,
Unit = new OpenNettyUnit
{
Definition = OpenNettyDevices.GetUnitByModel(OpenNettyBrand.Legrand, "67222", 4)!
}
});
```

### Actuator type (SCS-only)

Many MyHome/MyHome Up devices can be configured to either act as lighting or automation (i.e shutter/cover) devices.
To avoid ambiguities, OpenNetty requires that the actual type be specified for SCS products that support both modes:

```xml
<Device Brand="BTicino" Model="F411U2" SerialNumber="00B582A5">
<Endpoint Name="Garage/Recessed light 1" Area="4" Point="1">
<Setting Name="Actuator type" Value="Lighting" />
</Endpoint>
</Device>

<Device Brand="BTicino" Model="F411U2" SerialNumber="00A472A9">
<Endpoint Name="Living room/Shutter" Area="1" Point="3">
<Setting Name="Actuator type" Value="Automation" />
</Endpoint>
</Device>
```

### Action validation (Nitoo-only, powerline-only)

As they operate over an unreliable medium (i.e power lines), Nitoo PLC devices may not always receive some of the messages
sent by the OpenWebNet gateway. To mitigate that, these devices automatically report back whether a bus command or dimension set
demand was successfully applied or not using special VALID ACTION or INVALID ACTION diagnostic frames: OpenNetty monitors these
frames to determine whether the requested action was actually performed: when no confirmation is received, the initial message
is automatically retransmitted by OpenNetty until the maximum number of allowed retransmissions is reached (2 by default) or
the demand is confirmed by the remote device. If no positive confirmation is received, the command is assumed to be unsuccessful
and the state of the endpoint is assumed to be unchanged: for instance, when sending an ON command, the `SwitchStateReported`
event will not be triggered if the end device didn't report the command was succesful after the allowed number of retransmissions.

When necessary (e.g because a specific endpoint is known to have issues reporting frames back), this mechanism can be disabled:
in this case, every command is assumed to be successful (which is similar to Home Assistant's optimistic mode):

```xml
<Device Brand="Legrand" Model="67222" SerialNumber="487932">
<Setting Name="Action validation" Value="false" />

<Unit Id="4">
<Endpoint Name="Kitchen/Dimmable socket" />
</Unit>
</Device>
```

### Switch mode (SCS-only)

Using MyHome Suite, SCS devices can be configured to use a special PUL mode. When doing so, these devices basically work as
push buttons: they no longer react to area or general commands and automatically move back to the OFF state after being activated.

When using the PUL mode, it is strongly recommended to configure affected endpoints to use the `Push button`
switch mode so that OpenNetty can properly report the OFF state and ignore area and general commands.

```xml
<Device Brand="BTicino" Model="F411U1" SerialNumber="0019BF87">
<Endpoint Name="Patio/Doorbell" Area="9" Point="1">
<Setting Name="Switch mode" Value="Push button" />
</Endpoint>
</Device>
```

--------------