Notifications
You must be signed in to change notification settings - Fork 36
Using the MQTT set commands
With release 0.9.1 a list of set commands have been added to the MQTT set topic list. So from now on you can control your OTGW through MQTT using a list of logical names "set command" topics.
In the table below is the list of all the set commands available to you, and how they translate to the OTGW commands.
| settopic | OTGW command send | value |
|---|---|---|
| command | string | |
| setpoint | TT | temp = [number e.g. 20.5] |
| constant | TC | temp = [number e.g. 20.5] |
| outside | OT | temp = [number e.g. 20.5] |
| hotwater | HW | temp = [number e.g. 20.5] |
| gatewaymode | GW | on = 1 or off = R or 0 |
| setback | SB | temp = [number e.g. 20.5] |
| maxchsetpt | SH | temp = [number e.g. 20.5] |
| maxdhwsetpt | SW | temp = [number e.g. 20.5] |
| maxmodulation | MM | level = [0-100]% |
| ctrlsetpt | CS | temp = [number e.g. 20.5] |
| ctrlsetpt2 | C2 | temp = [number e.g. 20.5] |
| chenable | CH | on = 1 or off = 0 |
| chenable2 | H2 | on = 1 or off = 0 |
| ventsetpt | VS | level = [0-100]% |
| temperaturesensor | TS | function |
| addalternative | AA | function |
| delalternative | DA | function |
| unknownid | UI | function |
| knownid | KI | function |
| priomsg | PM | function |
| setresponse | SR | function |
| clearrespons | CR | function |
| resetcounter | RS | function |
| ignoretransitations | IT | function |
| overridehb | OH | function |
| forcethermostat | FT | function |
| voltageref | VR | function |
| debugptr | DP | function |
To find out what all commands mean you should read Schelte's firmware command page: https://otgw.tclcode.com/firmware.html
So from 0.9.1 onward you can simply send the right command, using a right set command.
topic: OTGW/set/otgw-8CAAB55908D6/setpoint
value: 21.5
The firmware will receive the MQTT message from the set topic and forward it to the OTGW this: TT=21.5
The generic command set topic is still available, to make sure it's backward compatible to all pre-0.9.1 releases.
topic: OTGW/set/otgw-8CAAB55908D6/command
value: TT=21.5
The firmware will convert this to the same message for the OTGW: TT=21.5
This way your automation in Node-red or YAML will be more readable.