The collector ships with a built-in HTTP server that exposes:
- A dark-theme HTML dashboard with auto-refresh and an interactive control modal per inverter.
- A JSON API for programmatic consumers (pv-stack-ui, scripts, etc.).
- Control endpoints for per-inverter power limit writes (covered in detail in POWER_LIMIT_CONTROL.md).
The server runs as a daemon thread inside the main process — it shares its lifetime with the collector and dies on shutdown.
monitoring:
enabled: true
port: 8080 # In-container port; Docker maps this to the hostEnvironment overrides: MONITORING_ENABLED=true, MONITORING_PORT=8080.
Default Docker port mappings (set in docker-compose.production.yml):
services:
fronius-inverters:
ports: ["8082:8080"]
fronius-meter:
ports: ["8083:8080"]| Method | Path | Description |
|---|---|---|
GET |
/ |
HTML dashboard. Auto-refreshes every 30 s (paused while the control modal is open). |
GET |
/?view=json |
Full JSON state — legacy alias kept for backwards compatibility. |
GET |
/api/data |
Identical payload to ?view=json (preferred for new clients). |
POST |
/api/inverter/{id}/power_limit |
Queue a power-limit write. Only registered when write.enabled: true. See POWER_LIMIT_CONTROL.md §3. |
POST |
/api/inverter/{id}/restore |
Queue a restore-to-100 % write. Same enablement rules as above. |
There is no authentication. The server binds on 0.0.0.0 inside
the container — protect it at the network layer (Docker network, firewall,
reverse proxy) if you expose it beyond the host.
{
"app": {
"version": "1.8.0",
"uptime_seconds": 12345,
"uptime_formatted": "3h25m",
"container_type": "inverter",
"hostname": "ee47163db2a5",
"pid": 1,
"timestamp": "2026-05-15 19:30:00"
},
"modbus": {
"host": "192.168.88.240",
"port": 502,
"connected": true,
"in_sleep_mode": false,
"is_night_time": false,
"successful_reads": 1234,
"failed_reads": 5
},
"devices": [
{
"device_id": 1,
"device_type": "inverter",
"manufacturer": "Fronius",
"model": "Symo Advanced 20.0-3-M",
"serial_number": "34559971",
"model_id": 103,
"status": "online",
"last_seen": "2026-05-15T19:30:00.123456",
"read_errors": 0,
"consecutive_errors": 0,
"power_limit_pct": 100.0,
"power_limit_enabled": false,
"controls_updated_at": 1715794200.12,
"active_override": null
}
],
"mqtt": {
"enabled": true,
"connected": true,
"broker": "mosquitto",
"port": 1883,
"messages_published": 1206,
"messages_skipped": 1053,
"disconnection_count": 0
},
"influxdb": {
"enabled": true,
"connected": true,
"url": "http://influxdb:8086",
"bucket": "fronius",
"writes_total": 47,
"writes_failed": 0,
"disconnection_count": 0
},
"write": {
"enabled": true,
"writes_total": 0,
"writes_failed": 0,
"active_limits": {},
"queue_size": 0,
"min_power_limit_pct": 10,
"max_power_limit_pct": 100,
"rate_limit_seconds": 30,
"auto_revert_seconds": 3600
},
"system": {
"memory_rss_mb": 72.6,
"memory_vms_mb": 583.3,
"threads": 8,
"pid": 1
},
"logs": [
"2026-05-15 19:30:00 - INFO - …",
"..."
]
}| Field | Type | Meaning |
|---|---|---|
power_limit_pct |
`float | null` |
power_limit_enabled |
`bool | null` |
controls_updated_at |
`float | null` |
active_override |
`object | null` |
- Version badge, hostname, container type (inverter / meter), uptime, auto-refresh status, JSON link.
- Modbus TCP — host:port, connection state, successful / failed read counters, sleep-mode indicator.
- MQTT — broker, connection state, publish / skip counters, disconnection count.
- InfluxDB — URL, connection state, write counters, disconnection count.
- Modbus Write (only when
write.enabled=true) — totals, queue depth, active limits summary. - System — RSS / VMS memory, thread count, PID.
| Column | Notes |
|---|---|
| ID | Modbus unit id. |
| Type | inverter / meter. |
| Model | SunSpec common-model Md string. |
| Serial | SunSpec common-model SN. |
| Status | online (green), offline (red), or unknown (amber, pre-first-poll). |
| Last Seen | HH:MM:SS of the last successful poll. |
| Errors | Read error counter across the device's lifetime. |
| Limit | Inverters only. Live power_limit_pct with colour coding (green ≥ 99.5, amber ≥ 50, red < 50). OVR badge when an override is tracked locally. (disabled) annotation when WMaxLim_Ena=0. |
| Control | Inverters only. Set button opens the power limit modal. Disabled (disabled text) when write.enabled=false. Always disabled for meters. |
- Reads the per-device log file (
logs/inverter.logorlogs/meter.log). - Newest first, capped at 200 displayed lines, 500 read, last 24 h.
- The dashboard's auto-refresh is client-side JavaScript (was a
<meta http-equiv="refresh">until v1.8.0). It pauses while the control modal is open or aPOSTis in flight, so a write in progress is never interrupted by a page reload. /api/datareturns a fresh snapshot on every call — there is no intermediate cache. Each request collects:- Modbus / MQTT / InfluxDB live stats from each publisher.
- Per-device runtime state from
DevicePoller. - Process metrics via
psutil. - Recent log lines from disk.
- The log viewer's "last 24 h" filter is timestamp-based; lines without a parseable timestamp (e.g. multi-line tracebacks) are kept verbatim.
- The HTTP server uses
log_level="warning"andaccess_log=False— successful requests are not logged. Failed requests still log at WARNING. To debug a request, hit/api/dataand inspect the response.
pv-stack-ui consumes /api/data directly (no authentication required
on the internal Docker network). The Control sub-tab in pv-stack-ui
uses the MQTT path (see POWER_LIMIT_CONTROL.md §4)
rather than the HTTP POST endpoints, so that other listeners (Node-RED
OV protection, Home Assistant, etc.) can observe the result stream.
In short:
- Diagnostics / one-off manual override → dashboard modal.
- Automation / control loops → MQTT.
- Programmatic state inspection →
GET /api/data.