Monitoring Dashboard — Reference

The collector ships with a built-in HTTP server that exposes:

  • A dark-theme HTML dashboard with auto-refresh and an interactive control modal per inverter.
  • A JSON API for programmatic consumers (pv-stack-ui, scripts, etc.).
  • Control endpoints for per-inverter power limit writes (covered in detail in POWER_LIMIT_CONTROL.md).

The server runs as a daemon thread inside the main process — it shares its lifetime with the collector and dies on shutdown.

Dashboard


1. Enabling

monitoring:
  enabled: true
  port: 8080            # In-container port; Docker maps this to the host

Environment overrides: MONITORING_ENABLED=true, MONITORING_PORT=8080.

Default Docker port mappings (set in docker-compose.production.yml):

services:
  fronius-inverters:
    ports: ["8082:8080"]
  fronius-meter:
    ports: ["8083:8080"]

2. Endpoints

Method Path Description
GET / HTML dashboard. Auto-refreshes every 30 s (paused while the control modal is open).
GET /?view=json Full JSON state — legacy alias kept for backwards compatibility.
GET /api/data Identical payload to ?view=json (preferred for new clients).
POST /api/inverter/{id}/power_limit Queue a power-limit write. Only registered when write.enabled: true. See POWER_LIMIT_CONTROL.md §3.
POST /api/inverter/{id}/restore Queue a restore-to-100 % write. Same enablement rules as above.

There is no authentication. The server binds on 0.0.0.0 inside the container — protect it at the network layer (Docker network, firewall, reverse proxy) if you expose it beyond the host.


3. JSON payload shape

{
  "app": {
    "version": "1.8.0",
    "uptime_seconds": 12345,
    "uptime_formatted": "3h25m",
    "container_type": "inverter",
    "hostname": "ee47163db2a5",
    "pid": 1,
    "timestamp": "2026-05-15 19:30:00"
  },
  "modbus": {
    "host": "192.168.88.240",
    "port": 502,
    "connected": true,
    "in_sleep_mode": false,
    "is_night_time": false,
    "successful_reads": 1234,
    "failed_reads": 5
  },
  "devices": [
    {
      "device_id": 1,
      "device_type": "inverter",
      "manufacturer": "Fronius",
      "model": "Symo Advanced 20.0-3-M",
      "serial_number": "34559971",
      "model_id": 103,
      "status": "online",
      "last_seen": "2026-05-15T19:30:00.123456",
      "read_errors": 0,
      "consecutive_errors": 0,
      "power_limit_pct": 100.0,
      "power_limit_enabled": false,
      "controls_updated_at": 1715794200.12,
      "active_override": null
    }
  ],
  "mqtt": {
    "enabled": true,
    "connected": true,
    "broker": "mosquitto",
    "port": 1883,
    "messages_published": 1206,
    "messages_skipped": 1053,
    "disconnection_count": 0
  },
  "influxdb": {
    "enabled": true,
    "connected": true,
    "url": "http://influxdb:8086",
    "bucket": "fronius",
    "writes_total": 47,
    "writes_failed": 0,
    "disconnection_count": 0
  },
  "write": {
    "enabled": true,
    "writes_total": 0,
    "writes_failed": 0,
    "active_limits": {},
    "queue_size": 0,
    "min_power_limit_pct": 10,
    "max_power_limit_pct": 100,
    "rate_limit_seconds": 30,
    "auto_revert_seconds": 3600
  },
  "system": {
    "memory_rss_mb": 72.6,
    "memory_vms_mb": 583.3,
    "threads": 8,
    "pid": 1
  },
  "logs": [
    "2026-05-15 19:30:00 - INFO - …",
    "..."
  ]
}

Inverter-specific fields

Field Type Meaning
power_limit_pct `float null`
power_limit_enabled `bool null`
controls_updated_at `float null`
active_override `object null`

4. UI feature reference

Header

  • Version badge, hostname, container type (inverter / meter), uptime, auto-refresh status, JSON link.

Cards (top row)

  • Modbus TCP — host:port, connection state, successful / failed read counters, sleep-mode indicator.
  • MQTT — broker, connection state, publish / skip counters, disconnection count.
  • InfluxDB — URL, connection state, write counters, disconnection count.
  • Modbus Write (only when write.enabled=true) — totals, queue depth, active limits summary.
  • System — RSS / VMS memory, thread count, PID.

Devices table

Column Notes
ID Modbus unit id.
Type inverter / meter.
Model SunSpec common-model Md string.
Serial SunSpec common-model SN.
Status online (green), offline (red), or unknown (amber, pre-first-poll).
Last Seen HH:MM:SS of the last successful poll.
Errors Read error counter across the device's lifetime.
Limit Inverters only. Live power_limit_pct with colour coding (green ≥ 99.5, amber ≥ 50, red < 50). OVR badge when an override is tracked locally. (disabled) annotation when WMaxLim_Ena=0.
Control Inverters only. Set button opens the power limit modal. Disabled (disabled text) when write.enabled=false. Always disabled for meters.

Log viewer

  • Reads the per-device log file (logs/inverter.log or logs/meter.log).
  • Newest first, capped at 200 displayed lines, 500 read, last 24 h.

5. Operational notes

  • The dashboard's auto-refresh is client-side JavaScript (was a <meta http-equiv="refresh"> until v1.8.0). It pauses while the control modal is open or a POST is in flight, so a write in progress is never interrupted by a page reload.
  • /api/data returns a fresh snapshot on every call — there is no intermediate cache. Each request collects:
    • Modbus / MQTT / InfluxDB live stats from each publisher.
    • Per-device runtime state from DevicePoller.
    • Process metrics via psutil.
    • Recent log lines from disk.
  • The log viewer's "last 24 h" filter is timestamp-based; lines without a parseable timestamp (e.g. multi-line tracebacks) are kept verbatim.
  • The HTTP server uses log_level="warning" and access_log=False — successful requests are not logged. Failed requests still log at WARNING. To debug a request, hit /api/data and inspect the response.

6. Integration with pv-stack-ui

pv-stack-ui consumes /api/data directly (no authentication required on the internal Docker network). The Control sub-tab in pv-stack-ui uses the MQTT path (see POWER_LIMIT_CONTROL.md §4) rather than the HTTP POST endpoints, so that other listeners (Node-RED OV protection, Home Assistant, etc.) can observe the result stream.

In short:

  • Diagnostics / one-off manual override → dashboard modal.
  • Automation / control loops → MQTT.
  • Programmatic state inspectionGET /api/data.