Security Policy

This project writes to live Fronius inverter Modbus registers when write.enabled=true (see docs/POWER_LIMIT_CONTROL.md), and exposes an unauthenticated HTTP control surface on the monitoring port when those writes are enabled. Vulnerabilities in either path can affect physical inverter operation, so we take reports seriously.

Supported versions

Security fixes are applied to the latest minor release and backported to the previous minor where practical. Older releases are best-effort.

Version Supported
1.8.x yes
1.7.x best-effort
< 1.7 no

Reporting a vulnerability

Please do not open a public GitHub issue for security reports.

Email stefan.maldaianu@gmail.com with:

  • A description of the issue and the affected component (collector, monitoring HTTP server, write protocol, MQTT command path, container image, build pipeline, …).
  • Steps to reproduce, including the configuration used (with secrets redacted) and the version / commit you tested against.
  • Impact: what an attacker on the same network / on the host / on the internet (if exposed) could achieve.
  • Any suggested fix, if you have one.

You can expect:

  • Acknowledgement within 5 business days.
  • A triage decision (accepted / declined / needs more info) within 10 business days.
  • A fix or mitigation plan for accepted reports within 30 days, depending on severity. Critical issues affecting write-path safety are prioritised.

I am a single maintainer working on this project in my spare time; realistic timelines are appreciated.

Out of scope

The following are explicitly out of scope:

  • Misconfiguration by the operator (e.g. exposing the monitoring port to the public internet without authentication, or enabling write on an untrusted network). The README and docs/MONITORING.md document the expected deployment model: behind a trusted network or a reverse proxy with authentication.
  • Vulnerabilities in third-party dependencies (pymodbus, paho-mqtt, influxdb-client, fastapi, uvicorn, psutil, etc.) — report those upstream. We will rebuild / bump versions when upstream releases a fix.
  • Issues in the Fronius DataManager firmware or in the Modbus TCP surface exposed by the inverter — report those to Fronius.
  • Denial of service achievable only by an attacker who already has full network access to a control-plane port (Modbus 502, monitoring HTTP). Those ports are not designed to survive a hostile actor on the same segment.

Hall of fame

Accepted reports will be credited in CHANGELOG.md under the release that fixes them, unless the reporter prefers to remain anonymous.

There aren't any published security advisories