The 2nd generation 5 kVA Power Hub is listed by the developer platform without a product name and every data request for it fails with error 1006, while the app's MQTT stream carries all of its modules (bbcin, bbcout, iclow, bp5000, kitscc, lddc, ichigh, ldac, wireless) as JSON wrapped twice. Add a POWER_KITS device type for private_api that reuses the public Power Kits entities, routes each module's heartbeat and the latestQuotas reply to its own sub device, and keeps the main battery's totals and the wireless module on the hub device. The config flow now discovers sub devices in the reconfigure flow too, and asks a private-API hub for latestQuotas over a short MQTT session to find its modules. quota_all sends one latestQuotas per topic instead of one per sub device. Commands reuse the 1st generation payloads and are untested on a 2nd generation hub. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
…power unit Built from a 5 kVA Power Hub's full latestQuotas reply and a minute of heartbeats: - The 2nd generation AC/DC panel (EF-PK-005-2) reports its AC board as ldac and its DC board as lddc under one serial; sub devices are listed by serial, so one board was dropped. Modules sharing a serial now get "<serial>#<type>" list keys while data routing, naming and commands keep using the real serial. - The hub device takes the system totals from the flat bmsTotal quota entry and from mainBP heartbeats: total current (signed 16-bit in 0.1 A), remaining time, charge and discharge limits, generator start and stop levels, plus the gps module. - New entities for what the 2nd generation reports: battery health and cumulative energy, inverter apparent power, charge power and effective settings (appCfg), DC circuits 13 to 16 and the L1/L2 AC buses. - Switches whose state is reported by another module than the one that takes the command (AC Output, AC Charging, charge current, Main DC Output) now live on the reporting module and address the sibling in the command; the DC panel has 12 relay switches. - pv1InWatts/pv2InWatts are reported in W, not 0.1 W (upstream issue tolwi#911); this also applies to the public Power Kits device. Commands remain unverified on 2nd generation hardware. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
…ion notes Home Assistant devices of the private-API Power Kits now carry EcoFlow's product names as their model (智控五合一充逆一体机 / Power Hub and its five functions, 磷酸铁锂电池 / LFP Battery with its capacity, the two boards of the 交直流智能配电盘 / AC/DC Smart Distribution Panel) and show the printed serial even when the sub device key carries a "#<type>" suffix. A device can set model_name; the entity base class falls back to the device type. docs/power_kits_2nd_gen.md collects the components, specifications, module to device map, serial prefixes, units and known limits of the 2nd generation 5 kVA kit, with the source of each figure. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
bp5000 is the 磷酸铁锂电池5度电 (LFP Battery 5kWh, 51.2 V / 100 Ah) and bp2000 the 磷酸铁锂电池2度电 (LFP Battery 2kWh, 51.2 V / 40 Ah), the only two packs offered for the Power Kits; any other bp type keeps a generic name. The 2nd generation notes get both packs' specifications. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
… remove Review follow-ups on the Power Kits sub devices: - Removing a hub takes its modules with it (entry data, options and the registry entries). A module whose parent is gone no longer raises in extract_devices and keeps the whole entry from loading; it is skipped with a warning instead. - The remove-device step no longer runs module discovery, which added the module just removed straight back. A removed module is recorded on its parent (ignored_modules) and left out of later discoveries. - Discovery now runs for every multi-module device on add and finish, merging modules that are not configured yet, so a battery or panel that was offline when the hub was added appears on the next reconfiguration. Configured sub devices keep their names and options. - A module missing from a latestQuotas reply no longer counts as fresh data: its status and readings are left alone instead of being marked online with empty params. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
…eration hub Captured from the app's set topic while switching things on a 5 kVA hub: - Main DC output goes to bbcout with module type 15363 (dischgParaSet, swSta), not to bbcin with 15362 as documented for the 1st generation. A Beeper switch uses the same message (beepEn). - DC input charging (alternator / generator) toggles chgPause through chgParaSet on bbcin. - The two solar ports toggle mpptt1 / mpptt2 through pvSwitch on kitscc. - Discharge lower and charge upper limits are socLowerLimit and socUpperLimit without a module serial; sliders on the hub device. - The DC panel's chSwitch uses module type 15368, and all 16 circuits answer to it; switches 13 to 16 read dcChRelayV2 and address channels 12 to 15 (BitMaskEnableEntity gains a command_index). - AC charging (acChgDisa through dischgIcParaSet on iclow) matches the 1st generation documentation. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
The hub's ALT IN n / PV IN n ports (port 1 on bbcin, ports 2 and 3 on kitscc) can be set to auto, alternator or solar. The app sends setPortType through chgParaSet for port 1 and setPort1Type / setPort2Type through pvSwitch for ports 2 and 3, with 0 auto, 1 alternator, 2 solar. Port 1 also takes the alternator type (chgDsgAltmodeSet, alternatorMode 0 generic, 1 48 V excited; a 48 V excited alternator disables reverse discharge on that port). All four become select entities, and the charging switches of the three ports are named by port number like the app. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
…s them The app sends acCurrMaxSet (charging) and passByMaxCurr (input) together in one dischgIcParaSet to iclow, 2 to 20 A and 2 to 50 A on a 230 V hub, and never lets the charging current exceed the input current. The ichigh device gets both sliders; each sends the other value from the current appCfg and caps the charging current at the input limit. The two diagnostic sensors for these values are replaced by the sliders. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
…per confirmed Captured from the app: grid priority (passByModeEn 1 grid, 2 battery) is set through dsgIcParaSet on iclow with invNoLoadPwr and setInvTag left unchanged, not on ichigh as the 1st generation code does; the switch stays on the ichigh device that reports the state. The beeper toggles beepEn exactly as implemented. The main DC output voltage is volTag (0/1, read back as cfgVolTag); it becomes a select that is disabled by default because 24 V can damage 12 V loads. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
Model EF-PK-O05-3, port ratings, supported devices, the one-dock-per-hub-port topology (docks cannot be chained), firmware and app notes; confirms the hub model EF-PK-H05-1 and lists the battery models EFM100-BP / EFM100-BPB. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
… Insight 2 The owner confirmed the console is the bundled display; Power Insight 2 was taken from a retailer page and is not part of this system. Its official Chinese name and specs are left to be filled in from the manual. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
Read the hub, console, panel, Power Dock, Power Link and battery manuals the owner provided. The hub spec table now comes from the hub manual (48 V output 55 A / 3168 W, 12/24 V output 1360 / 1584 W, 15.7 kg, battery port limits, EF BUS, total 8752 W) with a section on charge priority, bypass, grid priority, X-Fusion and idle charging. The console is the 智触监控屏 EFM100-MT (7-inch, EF BUS powered); the Power Link is the 信息集成盒 EF-PK-O05-1; the panel model is EF-PK-O05-2. Battery specs come from the official battery manual. The unknown-modules note and known limits are updated accordingly. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
The 2nd generation hub documents no X-Boost mode (only X-Fusion and the 10000 VA peak that the Chinese product page files under 升维驱动); the 5200 W X-Boost figure belongs to the 1st generation hub. A DELTA 2 Max joins the system only through its smart extra battery on the Power Dock's MULTI CONNECTION port with the Smart Generator Adapter. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
volTag 0 is 12 V and 1 is 24 V, captured while switching the main DC output in the app; the 48 V option of the app is noted as not captured yet. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
… voltage option The main DC output only offers 12 V and 24 V; the 48V tab shows the hub's 48 V DC OUT port (battery bus voltage for third-party loads) with power and status only. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
… off by default The DC and AC boards of the distribution panel answer getDcAllAlias / getAcAllAlias with the names the owner gave the circuits in the app. The private client asks once after connecting, the boards' devices also pick up every later reply, and the circuit sensors and switches rename themselves (entity ids keep the default titles). The AC output and grid priority switches are disabled by default: toggling grid priority remotely cut the AC output and with it the hub's uplink; recovery needed the hub's AC button. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
Documents the alias requests and how entities follow the app's circuit names, the two switches now disabled by default and why, that the app has no X-Boost switch, that this system has no Power Link, and that the alternator current and idle charging settings are not shown by the app on a home system without an alternator. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
Each circuit of the DC and AC boards gets a text entity holding the name the app shows; writing it sends setDcChAlias / setAcChAlias (both captured from the app) with the circuit's icon kept. A rename made in the app is seen on the set topic and applied at once. Adds the text platform, the docs generator's text section and the icon numbers to the notes. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
The app takes 24 letters or digits, or 8 Chinese characters: 24 bytes of UTF-8. Longer names are rejected with a service validation error. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LSsPaZYtMrC9vzT5hHeSRb
Contributor
There was a problem hiding this comment.
🟡 Changes recommended
Discovery can overwrite sibling devices or restore ignored boards, while removing iclow can misroute AC control commands to ichigh.
2 open issues
What changed in this PR
This PR adds second-generation Power Hub support to the EcoFlow Home Assistant integration, including module discovery, circuit controls and naming, and supporting documentation.
Changes:
- Adds private-API Power Kits devices, telemetry, controls, and circuit-name text entities.
- Extends module discovery and removal handling, including ignored modules and missing-parent recovery.
- Documents supported hardware, commands, entities, and operational limitations.
| File | Description |
|---|---|
| README.md | Adds setup guidance and the Power Kits entity summary. |
| docs/summary.md | Lists Power Kits entities by module. |
| docs/power_kits_2nd_gen.md | Documents hardware, protocol details, and limitations. |
| docs/integration.md | Links the new Power Kits documentation. |
| docs/gen.py | Generates hub/module sections and text-entity documentation. |
| docs/devices/POWER_KITS.md | Provides detailed entity and command references. |
| docs/device_management.md | Explains module removal and rediscovery. |
| custom_components/ecoflow_cloud/text.py | Sets up Home Assistant text entities. |
| custom_components/ecoflow_cloud/entities/__init__.py | Displays module models and real serial numbers. |
| custom_components/ecoflow_cloud/devices/registry.py | Registers private-API Power Kits support. |
| custom_components/ecoflow_cloud/devices/public/powerkit.py | Extends bitmask controls and module serial handling. |
| custom_components/ecoflow_cloud/devices/internal/powerkit.py | Implements private-API telemetry, controls, and circuit naming. |
| custom_components/ecoflow_cloud/devices/internal/powerkit_data.py | Parses module payloads and circuit-alias messages. |
| custom_components/ecoflow_cloud/devices/__init__.py | Adds text-entity and startup-command hooks. |
| custom_components/ecoflow_cloud/config_flow.py | Extends module discovery and removal tracking. |
| custom_components/ecoflow_cloud/api/private_api.py | Fetches discovery quotas over MQTT and requests startup settings. |
| custom_components/ecoflow_cloud/__init__.py | Registers text support and skips orphaned modules. |
Review effort: Balanced
Comment on lines
+188
to
+192
| key = sub_device_sn | ||
| if serial_count[sub_device_sn] > 1: | ||
| key = f"{sub_device_sn}{SN_TYPE_SEPARATOR}{sub_device_type}" | ||
| if (sub_device_type, sub_device_sn) in configured or key in ignored or sub_device_sn in ignored: | ||
| continue |
Comment on lines
+505
to
+506
| _LOGGER.warning("No %s module found for %s; sending the command to %s", module_type, parent.sn, self.module_sn) | ||
| return self.module_sn |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.

This pull request introduces comprehensive support for EcoFlow Power Kits (particularly the 2nd generation Power Hub) and improves handling of multi-module device discovery and configuration. It updates documentation, enhances the configuration flow to robustly discover and manage sub-devices (modules), and adds support for new Home Assistant entity types. The changes also ensure that missing parent devices do not block configuration loading, and that ignored modules are tracked.
Power Kits support and module discovery:
README.md. [1] [2]latestQuotasvia a short-lived MQTT session for module enumeration inprivate_api.py.Configuration flow and device management:
CONF_IGNORED_MODULESto track modules removed via the remove-device flow, ensuring ignored modules are not rediscovered. [1] [2]Device loading and error handling:
extract_devicesto gracefully handle sub-devices whose parent is missing, logging a warning and skipping them instead of failing the entire entry.Home Assistant integration:
Platform.TEXTentity type for Home Assistant, enabling support for text entities (such as naming circuits).Internal and dependency updates:
private_api.pyto support threading, asyncio, and MQTT for module discovery. [1] [2]These changes collectively enable robust, user-friendly integration of EcoFlow Power Kits and their modules into Home Assistant, with improved error handling and configuration flexibility.