@puddly puddly commented Jul 1, 2025

I'm going to be using 460800 baud for newer adapters.

57600 is used by I think one or two sticks, I wonder if it's time to drop it? Right now autoprobing is quite slow due to the sheer number of combinations.

@codecov
Copy link

codecov bot commented Jul 1, 2025

Codecov Report

All modified and coverable lines are covered by tests ✅

Project coverage is 99.44%. Comparing base (81e25be) to head (0862031).
Report is 1 commits behind head on dev.

Additional details and impacted files
@@           Coverage Diff           @@
##              dev     #677   +/-   ##
=======================================
  Coverage   99.44%   99.44%           
=======================================
  Files          52       52           
  Lines        3769     3769           
=======================================
  Hits         3748     3748           
  Misses         21       21           

☔ View full report in Codecov by Sentry.
📢 Have feedback on the report? Share it here.

🚀 New features to boost your workflow:
  • ❄️ Test Analytics: Detect flaky tests, report on failures, and find test suite problems.

@MattWestb
Copy link
Contributor

If i remember was old EM3X with original firmware using 57600 but the latest was compiled with 115200 but i think most of the EM3X dongles is now out then no current EZSP can being compiled for them plus need one tool-change that is very expensive and i think only Garry can do it in the community.
See old Wiki for hardware and EZSP version (all older then 6.7.8.0 is obselite) https://github.com/zigpy/zigpy/wiki/Coordinator-Firmware-Updates#recommended-firmware-versions-for-ezsp-coordinators

PS: most little older hardware with updated EZSP is using SW flow control at 115200 and only some hardware flow control so still importing have the 115200 probing.

@puddly
Copy link
Contributor Author

puddly commented Jul 1, 2025

The only stick that I have is the HUSBZB-1 with the original firmware (57600). All of the updated firmwares I think switch it to 115200?

@pipiche38
Copy link
Contributor

pipiche38 commented Jul 1, 2025

Would it make sense to start at 460800 then if no communication established switch to 115200 and finally to 57600?

@puddly
Copy link
Contributor Author

puddly commented Jul 1, 2025

This is precisely what ControllerApplication.probe does, these settings are specific to a radio library.

@MattWestb
Copy link
Contributor

The only stick that I have is the HUSBZB-1 with the original firmware (57600). All of the updated firmwares I think switch it to 115200?

Garry was cooking all community firmware for EM3X devices but i think it was both off some user was liking having the old slow HW and some like faster with SW but i think is nearly zero left of them now after Snoff and SC and so on.
If i have understanding right is only probing auto conf so if adding one coordinator manually its still possible setting the baud rate so shall working like before ding the probing = the EM3X time.

@puddly puddly merged commit 0a00d81 into zigpy:dev Jul 2, 2025
14 checks passed
@puddly
Copy link
Contributor Author

puddly commented Jul 2, 2025

We'll drop 57600 next release.