Notifications
You must be signed in to change notification settings - Fork 6
GridBoss Configuration
GridBoss is an advanced distribution monitoring and control system for LuxPower inverters. This guide covers setup and configuration.
GridBoss provides:
- 🔌 House Backup - Easy whole-house backup configuration
- ⚡ Smart Load Control - Manage up to 4 configurable SmartLoads
- 🔋 Generator Integration - Automatic start/stop control
- ☀️ AC Coupling - Monitor up to 4 external solar systems
- 📊 Split-Phase Monitoring - Individual L1, L2 tracking (USA standard)
- ⏰ Advanced Scheduling - Time-based automation with multiple schedules
Each of the 4 ports can be configured as either a SmartLoad or AC Coupling, but not both. The port mode determines which functionality is available for that specific port.
🔧 Configuration Sequence:
-
First: Set the port mode (
SmartLoadX_PortMode) to "Smart Load" or "Ac Coupled" - Then: Configure the port-specific settings (switches, numbers, time schedules, etc.)
❌ Common Mistake: Trying to configure port settings before setting the port mode will result in unavailable/grayed-out entities.
- ✅ LuxPower inverter
- ✅ Firmware code IAAB
- ✅ GridBoss hardware unit
- ✅ Integration v3.0.0+
During initial setup:
- Check "GridBoss Connected" option
- Complete setup normally
- Go to Settings → Devices & Services
- Find Monitor My Solar → Click Configure
- Select Update Settings
- Check "GridBoss Connected"
- Click Submit
- Integration will reload with GridBoss entities
When enabled, GridBoss adds 190+ new entities:
-
sensor.dongle_XX_midboxStatus- GridBoss Status -
sensor.dongle_XX_gridRMSVoltage- Grid RMS Voltage -
sensor.dongle_XX_buRMSVoltage- BU (Backup) RMS Voltage -
sensor.dongle_XX_genRMSVoltage- Generator RMS Voltage -
sensor.dongle_XX_PhaseLockFreq- Phase Lock Frequency -
sensor.dongle_XX_GridFreq- Grid Frequency -
sensor.dongle_XX_GenFreq- Generator Frequency -
sensor.dongle_XX_SmartPortMode- Smart Port Mode
-
sensor.dongle_XX_gridL1RMSVoltage- Grid L1 RMS Voltage -
sensor.dongle_XX_gridL2RMSVoltage- Grid L2 RMS Voltage -
sensor.dongle_XX_buL1RMSVoltage- BU L1 RMS Voltage -
sensor.dongle_XX_buL2RMSVoltage- BU L2 RMS Voltage -
sensor.dongle_XX_genL1RMSVoltage- Generator L1 RMS Voltage -
sensor.dongle_XX_genL2RMSVoltage- Generator L2 RMS Voltage
-
sensor.dongle_XX_gridL1RMSCurrent- Grid L1 RMS Current -
sensor.dongle_XX_gridL2RMSCurrent- Grid L2 RMS Current -
sensor.dongle_XX_loadL1RMSCurrent- Load L1 RMS Current -
sensor.dongle_XX_loadL2RMSCurrent- Load L2 RMS Current -
sensor.dongle_XX_genL1RMSCurrent- Generator L1 RMS Current -
sensor.dongle_XX_genL2RMSCurrent- Generator L2 RMS Current -
sensor.dongle_XX_buL1RMSCurrent- BU L1 RMS Current -
sensor.dongle_XX_buL2RMSCurrent- BU L2 RMS Current
-
sensor.dongle_XX_smartLoad1L1RMSCurrent- SmartLoad1 L1 RMS Current -
sensor.dongle_XX_smartLoad1L2RMSCurrent- SmartLoad1 L2 RMS Current -
sensor.dongle_XX_smartLoad2L1RMSCurrent- SmartLoad2 L1 RMS Current -
sensor.dongle_XX_smartLoad2L2RMSCurrent- SmartLoad2 L2 RMS Current -
sensor.dongle_XX_smartLoad3L1RMSCurrent- SmartLoad3 L1 RMS Current -
sensor.dongle_XX_smartLoad3L2RMSCurrent- SmartLoad3 L2 RMS Current -
sensor.dongle_XX_smartLoad4L1RMSCurrent- SmartLoad4 L1 RMS Current -
sensor.dongle_XX_smartLoad4L2RMSCurrent- SmartLoad4 L2 RMS Current
-
sensor.dongle_XX_gridL1ActivePower- Grid L1 Active Power -
sensor.dongle_XX_gridL2ActivePower- Grid L2 Active Power -
sensor.dongle_XX_loadL1ActivePower- Load L1 Active Power -
sensor.dongle_XX_loadL2ActivePower- Load L2 Active Power -
sensor.dongle_XX_genL1ActivePower- Generator L1 Active Power -
sensor.dongle_XX_genL2ActivePower- Generator L2 Active Power -
sensor.dongle_XX_buL1ActivePower- BU L1 Active Power -
sensor.dongle_XX_buL2ActivePower- BU L2 Active Power
-
sensor.dongle_XX_smartLoad1L1ActivePower- SmartLoad1 L1 Active Power -
sensor.dongle_XX_smartLoad1L2ActivePower- SmartLoad1 L2 Active Power -
sensor.dongle_XX_smartLoad2L1ActivePower- SmartLoad2 L1 Active Power -
sensor.dongle_XX_smartLoad2L2ActivePower- SmartLoad2 L2 Active Power -
sensor.dongle_XX_smartLoad3L1ActivePower- SmartLoad3 L1 Active Power -
sensor.dongle_XX_smartLoad3L2ActivePower- SmartLoad3 L2 Active Power -
sensor.dongle_XX_smartLoad4L1ActivePower- SmartLoad4 L1 Active Power -
sensor.dongle_XX_smartLoad4L2ActivePower- SmartLoad4 L2 Active Power
-
sensor.dongle_XX_eLoad_TodayAll- E Load Today All -
sensor.dongle_XX_EtoGrid_TodayAll- E to Grid Today All -
sensor.dongle_XX_EtoUser_TodayAll- E to User Today All -
sensor.dongle_XX_Egen_TodayAll- E Gen Today All -
sensor.dongle_XX_ESmartLoad1_TodayAll- E SmartLoad1 Today All -
sensor.dongle_XX_ESmartLoad2_TodayAll- E SmartLoad2 Today All -
sensor.dongle_XX_ESmartLoad3_TodayAll- E SmartLoad3 Today All -
sensor.dongle_XX_ESmartLoad4_TodayAll- E SmartLoad4 Today All -
sensor.dongle_XX_EAcouple1_TodayAll- E ACcouple1 Today All -
sensor.dongle_XX_EAcouple2_TodayAll- E ACcouple2 Today All -
sensor.dongle_XX_EAcouple3_TodayAll- E ACcouple3 Today All -
sensor.dongle_XX_EAcouple4_TodayAll- E ACcouple4 Today All
-
sensor.dongle_XX_ELoad_total- E Load Total -
sensor.dongle_XX_EBU_Total- E BU Total -
sensor.dongle_XX_EtoGrid_total- E to Grid Total -
sensor.dongle_XX_EtoUser_total- E to User Total -
sensor.dongle_XX_Egen_total- E Gen Total -
sensor.dongle_XX_ESmartLoad1_total- E SmartLoad1 Total -
sensor.dongle_XX_ESmartLoad2_total- E SmartLoad2 Total -
sensor.dongle_XX_ESmartLoad3_total- E SmartLoad3 Total -
sensor.dongle_XX_ESmartLoad4_total- E SmartLoad4 Total -
sensor.dongle_XX_EAcouple1_total- E ACcouple1 Total -
sensor.dongle_XX_EAcouple2_total- E ACcouple2 Total -
sensor.dongle_XX_EAcouple3_total- E ACcouple3 Total -
sensor.dongle_XX_EAcouple4_total- E ACcouple4 Total -
sensor.dongle_XX_MIDBoox_ACType- MIDBox AC Type
-
switch.dongle_XX_Generator_enable- Generator Enable
-
switch.dongle_XX_SmartLoad1_Enable- SmartLoad1 Enable -
switch.dongle_XX_SmartLoad2_Enable- SmartLoad2 Enable -
switch.dongle_XX_SmartLoad3_Enable- SmartLoad3 Enable -
switch.dongle_XX_SmartLoad4_Enable- SmartLoad4 Enable -
switch.dongle_XX_SmartLoad1_GridOn- SmartLoad1 Grid On -
switch.dongle_XX_SmartLoad2_GridOn- SmartLoad2 Grid On -
switch.dongle_XX_SmartLoad3_GridOn- SmartLoad3 Grid On -
switch.dongle_XX_SmartLoad4_GridOn- SmartLoad4 Grid On -
switch.dongle_XX_SmartLoad1_Shedding- SmartLoad1 Shedding -
switch.dongle_XX_SmartLoad2_Shedding- SmartLoad2 Shedding -
switch.dongle_XX_SmartLoad3_Shedding- SmartLoad3 Shedding -
switch.dongle_XX_SmartLoad4_Shedding- SmartLoad4 Shedding
-
switch.dongle_XX_ACcouple1_Enable- ACcouple1 Enable -
switch.dongle_XX_ACcouple2_Enable- ACcouple2 Enable -
switch.dongle_XX_ACcouple3_Enable- ACcouple3 Enable -
switch.dongle_XX_ACcouple4_Enable- ACcouple4 Enable
-
number.dongle_XX_Generator_Warmup- Generator Warmup Time (0-600s) -
number.dongle_XX_Generator_CoolDown- Generator Cool Down Time (0-600s) -
number.dongle_XX_Generator_Exercise_Period- Generator Exercise Period (0-365d)
-
number.dongle_XX_SmartLoad1_StartSOC- SmartLoad1 Start SOC (0-100%) -
number.dongle_XX_SmartLoad1_EndSOC- SmartLoad1 End SOC (0-100%) -
number.dongle_XX_SmartLoad2_StartSOC- SmartLoad2 Start SOC (0-100%) -
number.dongle_XX_SmartLoad2_EndSOC- SmartLoad2 End SOC (0-100%) -
number.dongle_XX_SmartLoad3_StartSOC- SmartLoad3 Start SOC (0-100%) -
number.dongle_XX_SmartLoad3_EndSOC- SmartLoad3 End SOC (0-100%) -
number.dongle_XX_SmartLoad4_StartSOC- SmartLoad4 Start SOC (0-100%) -
number.dongle_XX_SmartLoad4_EndSOC- SmartLoad4 End SOC (0-100%)
-
number.dongle_XX_SmartLoad1_StartVolt- SmartLoad1 Start Voltage (40-60V) -
number.dongle_XX_SmartLoad1_EndVolt- SmartLoad1 End Voltage (40-60V) -
number.dongle_XX_SmartLoad2_StartVolt- SmartLoad2 Start Voltage (40-60V) -
number.dongle_XX_SmartLoad2_EndVolt- SmartLoad2 End Voltage (40-60V) -
number.dongle_XX_SmartLoad3_StartVolt- SmartLoad3 Start Voltage (40-60V) -
number.dongle_XX_SmartLoad3_EndVolt- SmartLoad3 End Voltage (40-60V) -
number.dongle_XX_SmartLoad4_StartVolt- SmartLoad4 Start Voltage (40-60V) -
number.dongle_XX_SmartLoad4_EndVolt- SmartLoad4 End Voltage (40-60V)
-
number.dongle_XX_ACcouple1_StartSOC- ACcouple1 Start SOC (0-100%) -
number.dongle_XX_ACcouple1_EndSOC- ACcouple1 End SOC (0-100%) -
number.dongle_XX_ACcouple2_StartSOC- ACcouple2 Start SOC (0-100%) -
number.dongle_XX_ACcouple2_EndSOC- ACcouple2 End SOC (0-100%) -
number.dongle_XX_ACcouple3_StartSOC- ACcouple3 Start SOC (0-100%) -
number.dongle_XX_ACcouple3_EndSOC- ACcouple3 End SOC (0-100%) -
number.dongle_XX_ACcouple4_StartSOC- ACcouple4 Start SOC (0-100%) -
number.dongle_XX_ACcouple4_EndSOC- ACcouple4 End SOC (0-100%)
-
number.dongle_XX_ACcouple1_StartVolt- ACcouple1 Start Voltage (40-60V) -
number.dongle_XX_ACcouple1_EndVolt- ACcouple1 End Voltage (40-60V) -
number.dongle_XX_ACcouple2_StartVolt- ACcouple2 Start Voltage (40-60V) -
number.dongle_XX_ACcouple2_EndVolt- ACcouple2 End Voltage (40-60V) -
number.dongle_XX_ACcouple3_StartVolt- ACcouple3 Start Voltage (40-60V) -
number.dongle_XX_ACcouple3_EndVolt- ACcouple3 End Voltage (40-60V) -
number.dongle_XX_ACcouple4_StartVolt- ACcouple4 Start Voltage (40-60V) -
number.dongle_XX_ACcouple4_EndVolt- ACcouple4 End Voltage (40-60V)
-
number.dongle_XX_SmartLoad1_SheddingStartPv_Power- SmartLoad1 Shedding Start PV Power (0-10000W) -
number.dongle_XX_SmartLoad2_SheddingStartPv_Power- SmartLoad2 Shedding Start PV Power (0-10000W) -
number.dongle_XX_SmartLoad3_SheddingStartPv_Power- SmartLoad3 Shedding Start PV Power (0-10000W) -
number.dongle_XX_SmartLoad4_SheddingStartPv_Power- SmartLoad4 Shedding Start PV Power (0-10000W) -
number.dongle_XX_SmartLoad1_SheddingStartSOC- SmartLoad1 Shedding Start SOC (0-100%) -
number.dongle_XX_SmartLoad1_SheddingEndSOC- SmartLoad1 Shedding End SOC (0-100%) -
number.dongle_XX_SmartLoad2_SheddingStartSOC- SmartLoad2 Shedding Start SOC (0-100%) -
number.dongle_XX_SmartLoad2_SheddingEndSOC- SmartLoad2 Shedding End SOC (0-100%) -
number.dongle_XX_SmartLoad3_SheddingStartSOC- SmartLoad3 Shedding Start SOC (0-100%) -
number.dongle_XX_SmartLoad3_SheddingEndSOC- SmartLoad3 Shedding End SOC (0-100%) -
number.dongle_XX_SmartLoad4_SheddingStartSOC- SmartLoad4 Shedding Start SOC (0-100%) -
number.dongle_XX_SmartLoad4_SheddingEndSOC- SmartLoad4 Shedding End SOC (0-100%) -
number.dongle_XX_SmartLoad1_SheddingStartVolt- SmartLoad1 Shedding Start Voltage (40-60V) -
number.dongle_XX_SmartLoad1_SheddingEndVolt- SmartLoad1 Shedding End Voltage (40-60V) -
number.dongle_XX_SmartLoad2_SheddingStartVolt- SmartLoad2 Shedding Start Voltage (40-60V) -
number.dongle_XX_SmartLoad2_SheddingEndVolt- SmartLoad2 Shedding End Voltage (40-60V) -
number.dongle_XX_SmartLoad3_SheddingStartVolt- SmartLoad3 Shedding Start Voltage (40-60V) -
number.dongle_XX_SmartLoad3_SheddingEndVolt- SmartLoad3 Shedding End Voltage (40-60V) -
number.dongle_XX_SmartLoad4_SheddingStartVolt- SmartLoad4 Shedding Start Voltage (40-60V) -
number.dongle_XX_SmartLoad4_SheddingEndVolt- SmartLoad4 Shedding End Voltage (40-60V) -
number.dongle_XX_Flash_5060hz- Flash 50/60Hz (0-1) -
number.dongle_XX_NEC_120CurrLimit- NEC 120 Current Limit (0-200A)
-
select.dongle_XX_SmartLoad1_PortMode- Smart Port 1 (Does Not Operate, Smart Load, Ac Coupled) -
select.dongle_XX_SmartLoad2_PortMode- Smart Port 2 (Does Not Operate, Smart Load, Ac Coupled) -
select.dongle_XX_SmartLoad3_PortMode- Smart Port 3 (Does Not Operate, Smart Load, Ac Coupled) -
select.dongle_XX_SmartLoad4_PortMode- Smart Port 4 (Does Not Operate, Smart Load, Ac Coupled)
Port Mode Options:
- "Does Not Operate" - Port is disabled
- "Smart Load" - Port functions as a SmartLoad (load control)
- "Ac Coupled" - Port functions as AC Coupling (external solar monitoring)
-
select.dongle_XX_SmartLoad1_SOC_Volt- Smart Load 1 Mode (Time, SOC/Volt) -
select.dongle_XX_SmartLoad2_SOC_Volt- Smart Load 2 Mode (Time, SOC/Volt) -
select.dongle_XX_SmartLoad3_SOC_Volt- Smart Load 3 Mode (Time, SOC/Volt) -
select.dongle_XX_SmartLoad4_SOC_Volt- Smart Load 4 Mode (Time, SOC/Volt)
SmartLoad Mode Options:
- "Time" - SmartLoad operates based on time schedules
- "SOC/Volt" - SmartLoad operates based on battery SOC/voltage thresholds
Each SmartLoad has 3 time schedules (Start0/End0, Start1/End1, Start2/End2):
-
time.dongle_XX_SmartLoad1Start0- SmartLoad1 Start0 -
time.dongle_XX_SmartLoad1End0- SmartLoad1 End0 -
time.dongle_XX_SmartLoad1Start1- SmartLoad1 Start1 -
time.dongle_XX_SmartLoad1End1- SmartLoad1 End1 -
time.dongle_XX_SmartLoad1Start2- SmartLoad1 Start2 -
time.dongle_XX_SmartLoad1End2- SmartLoad1 End2 -
time.dongle_XX_SmartLoad2Start0- SmartLoad2 Start0 -
time.dongle_XX_SmartLoad2End0- SmartLoad2 End0 -
time.dongle_XX_SmartLoad2Start1- SmartLoad2 Start1 -
time.dongle_XX_SmartLoad2End1- SmartLoad2 End1 -
time.dongle_XX_SmartLoad2Start2- SmartLoad2 Start2 -
time.dongle_XX_SmartLoad2End2- SmartLoad2 End2 -
time.dongle_XX_SmartLoad3Start0- SmartLoad3 Start0 -
time.dongle_XX_SmartLoad3End0- SmartLoad3 End0 -
time.dongle_XX_SmartLoad3Start1- SmartLoad3 Start1 -
time.dongle_XX_SmartLoad3End1- SmartLoad3 End1 -
time.dongle_XX_SmartLoad3Start2- SmartLoad3 Start2 -
time.dongle_XX_SmartLoad3End2- SmartLoad3 End2 -
time.dongle_XX_SmartLoad4Start0- SmartLoad4 Start0 -
time.dongle_XX_SmartLoad4End0- SmartLoad4 End0 -
time.dongle_XX_SmartLoad4Start1- SmartLoad4 Start1 -
time.dongle_XX_SmartLoad4End1- SmartLoad4 End1 -
time.dongle_XX_SmartLoad4Start2- SmartLoad4 Start2 -
time.dongle_XX_SmartLoad4End2- SmartLoad4 End2
Each AC Coupling port has 3 time schedules (Start0/End0, Start1/End1, Start2/End2):
-
time.dongle_XX_ACcouple1Start0- ACcouple1 Start0 -
time.dongle_XX_ACcouple1End0- ACcouple1 End0 -
time.dongle_XX_ACcouple1Start1- ACcouple1 Start1 -
time.dongle_XX_ACcouple1End1- ACcouple1 End1 -
time.dongle_XX_ACcouple1Start2- ACcouple1 Start2 -
time.dongle_XX_ACcouple1End2- ACcouple1 End2 -
time.dongle_XX_ACcouple2Start0- ACcouple2 Start0 -
time.dongle_XX_ACcouple2End0- ACcouple2 End0 -
time.dongle_XX_ACcouple2Start1- ACcouple2 Start1 -
time.dongle_XX_ACcouple2End1- ACcouple2 End1 -
time.dongle_XX_ACcouple2Start2- ACcouple2 Start2 -
time.dongle_XX_ACcouple2End2- ACcouple2 End2 -
time.dongle_XX_ACcouple3Start0- ACcouple3 Start0 -
time.dongle_XX_ACcouple3End0- ACcouple3 End0 -
time.dongle_XX_ACcouple3Start1- ACcouple3 Start1 -
time.dongle_XX_ACcouple3End1- ACcouple3 End1 -
time.dongle_XX_ACcouple3Start2- ACcouple3 Start2 -
time.dongle_XX_ACcouple3End2- ACcouple3 End2 -
time.dongle_XX_ACcouple4Start0- ACcouple4 Start0 -
time.dongle_XX_ACcouple4End0- ACcouple4 End0 -
time.dongle_XX_ACcouple4Start1- ACcouple4 Start1 -
time.dongle_XX_ACcouple4End1- ACcouple4 End1 -
time.dongle_XX_ACcouple4Start2- ACcouple4 Start2 -
time.dongle_XX_ACcouple4End2- ACcouple4 End2
Control SmartLoads based on battery SOC:
automation:
- alias: "Disable non-essential SmartLoads on low battery"
trigger:
- platform: numeric_state
entity_id: sensor.dongle_12_34_56_78_90_ab_soc
below: 20
action:
- service: switch.turn_off
entity_id:
- switch.dongle_12_34_56_78_90_ab_SmartLoad3_Enable
- switch.dongle_12_34_56_78_90_ab_SmartLoad4_EnableStart generator on low battery:
automation:
- alias: "Auto-start generator"
trigger:
- platform: numeric_state
entity_id: sensor.dongle_12_34_56_78_90_ab_vbat
below: 47.5
condition:
- condition: state
entity_id: switch.dongle_12_34_56_78_90_ab_Generator_enable
state: "off"
action:
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_Generator_enable
- service: notify.mobile_app
data:
message: "Generator started - Low battery voltage"Schedule SmartLoads for off-peak usage:
# First, configure the port as a SmartLoad with Time mode
script:
setup_smartload_time_mode:
sequence:
# Step 1: Set port mode to Smart Load (REQUIRED FIRST)
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_PortMode
data:
option: "Smart Load"
# Step 2: Set SmartLoad mode to Time
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_SOC_Volt
data:
option: "Time"
# Then use automations to control the SmartLoad
automation:
- alias: "Enable water heater off-peak"
trigger:
- platform: time
at: "23:00:00"
action:
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_SmartLoad1_Enable
- alias: "Disable water heater peak"
trigger:
- platform: time
at: "06:00:00"
action:
- service: switch.turn_off
entity_id: switch.dongle_12_34_56_78_90_ab_SmartLoad1_EnableConfigure SmartLoad to operate based on battery SOC:
script:
configure_smartload_soc:
sequence:
# Step 1: Set port mode to Smart Load (REQUIRED FIRST)
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_PortMode
data:
option: "Smart Load"
# Step 2: Set SmartLoad mode to SOC/Volt
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_SOC_Volt
data:
option: "SOC/Volt"
# Step 3: Configure SOC thresholds
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_SmartLoad1_StartSOC
data:
value: 80 # Start when SOC > 80%
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_SmartLoad1_EndSOC
data:
value: 20 # Stop when SOC < 20%Configure AC coupling for external solar:
script:
configure_ac_coupling:
sequence:
# First, set port mode to AC Coupled (this disables SmartLoad functionality)
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_PortMode
data:
option: "Ac Coupled"
# Then enable AC coupling
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_ACcouple1_Enable
# Configure AC coupling SOC thresholds
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_ACcouple1_StartSOC
data:
value: 90 # Start AC coupling when SOC > 90%script:
configure_mixed_ports:
sequence:
# Port 1: SmartLoad
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_PortMode
data:
option: "Smart Load"
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_SOC_Volt
data:
option: "SOC/Volt"
# Port 2: AC Coupling
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad2_PortMode
data:
option: "Ac Coupled"
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_ACcouple2_Enable
# Port 3: Disabled
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad3_PortMode
data:
option: "Does Not Operate"
# Port 4: SmartLoad with Time mode
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad4_PortMode
data:
option: "Smart Load"
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad4_SOC_Volt
data:
option: "Time"script:
convert_port_to_ac_coupling:
sequence:
# Step 1: Disable SmartLoad first
- service: switch.turn_off
entity_id: switch.dongle_12_34_56_78_90_ab_SmartLoad1_Enable
# Step 2: Change port mode to AC Coupled
- service: select.select_option
target:
entity_id: select.dongle_12_34_56_78_90_ab_SmartLoad1_PortMode
data:
option: "Ac Coupled"
# Step 3: Enable AC coupling
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_ACcouple1_EnableCreate a card showing split-phase balance (USA standard):
type: entities
title: Split-Phase Balance
entities:
- entity: sensor.dongle_12_34_56_78_90_ab_gridL1ActivePower
name: L1 Power
- entity: sensor.dongle_12_34_56_78_90_ab_gridL2ActivePower
name: L2 Power
- type: divider
- entity: sensor.dongle_12_34_56_78_90_ab_gridL1RMSVoltage
name: L1 Voltage
- entity: sensor.dongle_12_34_56_78_90_ab_gridL2RMSVoltage
name: L2 VoltageMonitor external solar systems:
- Enable AC coupling:
switch.dongle_12_34_56_78_90_ab_ACcouple1_Enable: on- Monitor AC-coupled power:
sensor.dongle_12_34_56_78_90_ab_EAcouple1_TodayAll # Today's energy
sensor.dongle_12_34_56_78_90_ab_EAcouple1_total # Total energyConfigure SmartLoad shedding based on PV power and SOC:
script:
configure_smartload_shedding:
sequence:
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_SmartLoad1_Shedding
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_SmartLoad1_SheddingStartPv_Power
data:
value: 5000 # Start shedding when PV > 5kW
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_SmartLoad1_SheddingStartSOC
data:
value: 30 # Start shedding when SOC < 30%Configure generator with warmup and cooldown periods:
script:
configure_generator:
sequence:
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_Generator_Warmup
data:
value: 60 # 60 second warmup
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_Generator_CoolDown
data:
value: 120 # 2 minute cooldown
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_Generator_Exercise_Period
data:
value: 7 # Exercise weeklytype: vertical-stack
cards:
- type: entities
title: GridBoss Status
entities:
- entity: sensor.dongle_12_34_56_78_90_ab_gridL1ActivePower
name: Grid L1 Power
- entity: sensor.dongle_12_34_56_78_90_ab_gridL2ActivePower
name: Grid L2 Power
- entity: sensor.dongle_12_34_56_78_90_ab_loadL1ActivePower
name: Load L1 Power
- entity: sensor.dongle_12_34_56_78_90_ab_loadL2ActivePower
name: Load L2 Power
- entity: sensor.dongle_12_34_56_78_90_ab_genL1ActivePower
name: Generator L1 Power
- entity: sensor.dongle_12_34_56_78_90_ab_genL2ActivePower
name: Generator L2 Power
- type: horizontal-stack
cards:
- type: gauge
entity: sensor.dongle_12_34_56_78_90_ab_gridL1RMSVoltage
name: L1 Voltage
min: 200
max: 260
- type: gauge
entity: sensor.dongle_12_34_56_78_90_ab_gridL2RMSVoltage
name: L2 Voltage
min: 200
max: 260type: entities
title: SmartLoad Control
entities:
- entity: switch.dongle_12_34_56_78_90_ab_SmartLoad1_Enable
name: Water Heater
secondary_info: last-changed
- entity: switch.dongle_12_34_56_78_90_ab_SmartLoad2_Enable
name: Pool Pump
- entity: switch.dongle_12_34_56_78_90_ab_SmartLoad3_Enable
name: Air Conditioner
- entity: switch.dongle_12_34_56_78_90_ab_SmartLoad4_Enable
name: EV Chargertype: entities
title: AC Coupling Status
entities:
- entity: switch.dongle_12_34_56_78_90_ab_ACcouple1_Enable
name: AC Couple 1
- entity: switch.dongle_12_34_56_78_90_ab_ACcouple2_Enable
name: AC Couple 2
- entity: switch.dongle_12_34_56_78_90_ab_ACcouple3_Enable
name: AC Couple 3
- entity: switch.dongle_12_34_56_78_90_ab_ACcouple4_Enable
name: AC Couple 4
- type: divider
- entity: sensor.dongle_12_34_56_78_90_ab_EAcouple1_TodayAll
name: AC Couple 1 Today
- entity: sensor.dongle_12_34_56_78_90_ab_EAcouple2_TodayAll
name: AC Couple 2 Today
- entity: sensor.dongle_12_34_56_78_90_ab_EAcouple3_TodayAll
name: AC Couple 3 Today
- entity: sensor.dongle_12_34_56_78_90_ab_EAcouple4_TodayAll
name: AC Couple 4 Today-
Verify firmware code is IAAB:
- Check in integration configuration status
- Look in Home Assistant logs
-
Ensure GridBoss is enabled:
- Integration → Configure → Update Settings
- Check "GridBoss Connected"
-
Restart Home Assistant after enabling
-
Check generator is enabled:
switch.dongle_12_34_56_78_90_ab_Generator_enable
-
Verify generator settings:
number.dongle_12_34_56_78_90_ab_Generator_Warmupnumber.dongle_12_34_56_78_90_ab_Generator_CoolDown
-
Check physical connections
-
First, verify port mode is set to Smart Load:
-
select.dongle_12_34_56_78_90_ab_SmartLoad1_PortMode= "Smart Load" - Critical: Port must be in "Smart Load" mode before any SmartLoad settings are available
-
-
Verify SmartLoad is enabled:
-
switch.dongle_12_34_56_78_90_ab_SmartLoad1_Enable(etc.)
-
-
Check SmartLoad mode configuration:
-
select.dongle_12_34_56_78_90_ab_SmartLoad1_SOC_Volt(Time or SOC/Volt)
-
-
Verify SOC/voltage settings (only available if mode is SOC/Volt):
number.dongle_12_34_56_78_90_ab_SmartLoad1_StartSOCnumber.dongle_12_34_56_78_90_ab_SmartLoad1_EndSOC
-
Monitor SmartLoad current/power sensors:
sensor.dongle_12_34_56_78_90_ab_smartLoad1L1RMSCurrentsensor.dongle_12_34_56_78_90_ab_smartLoad1L1ActivePower
-
First, verify port mode is set to AC Coupled:
-
select.dongle_12_34_56_78_90_ab_SmartLoad1_PortMode= "Ac Coupled" - Critical: Port must be in "Ac Coupled" mode before any AC Coupling settings are available
-
-
Verify AC coupling is enabled:
switch.dongle_12_34_56_78_90_ab_ACcouple1_Enable
-
Monitor AC coupling energy:
sensor.dongle_12_34_56_78_90_ab_EAcouple1_TodayAll
-
Cannot use both SmartLoad and AC Coupling on same port:
- If port is set to "Smart Load", AC Coupling entities will be unavailable
- If port is set to "Ac Coupled", SmartLoad entities will be unavailable
- Change port mode first, then configure the desired functionality
-
Configuration sequence is critical:
-
Step 1: Set port mode (
SmartLoadX_PortMode) to "Smart Load" or "Ac Coupled" - Step 2: Configure port-specific settings (switches, numbers, time schedules)
- ❌ Wrong: Trying to configure settings before setting port mode results in unavailable entities
-
Step 1: Set port mode (
-
Entity availability based on port mode:
- "Smart Load" mode: SmartLoad switches, SOC/Volt settings, time schedules available
- "Ac Coupled" mode: AC Coupling switches, AC Coupling SOC/Volt settings, AC Coupling time schedules available
- "Does Not Operate" mode: All port-specific entities unavailable
- Test Thoroughly: Test SmartLoad switching and generator control during installation
- Set Appropriate SOC/Voltage Limits: Configure SOC and voltage thresholds for SmartLoads
- Monitor Split-Phase Balance: Keep L1/L2 phases balanced for optimal performance
- Document Connections: Label all GridBoss connections clearly
- Regular Testing: Test generator auto-start monthly
- Configure Shedding: Set up SmartLoad shedding for grid stability
- Use Time Schedules: Configure multiple time schedules for flexible load management
- Monitor AC Coupling: Track external solar system performance
- Plan Port Configuration: Decide which ports will be SmartLoads vs AC Coupling before configuration
- Port Mode First: Always set port mode before configuring port-specific settings
- Understand Exclusivity: Remember that each port can only be one type at a time
For GridBoss-specific issues:
- Include firmware code (IAAB) in reports
- List which GridBoss features are enabled
- Provide debug logs with GridBoss MQTT topics
- Include photos of physical connections if relevant