This page details all available entities for LuxPower inverters supported by the Monitor My Solar integration.
| Type | Count | Description |
|---|---|---|
| Sensors | 200+ | Power, energy, voltage, current, temperature, status, GridBoss monitoring |
| Binary Sensors | 2 | Battery charge/discharge indicators |
| Switches | 25+ | EPS, charging, discharge, operation modes, GridBoss controls |
| Numbers | 80+ | Limits, thresholds, power settings, GridBoss configuration |
| Time | 50+ | Charge/discharge schedules, GridBoss load scheduling |
| Select | 60+ | Time-based operation modes, GridBoss port modes |
| Buttons | 2 | Restart inverter, firmware updates |
| Update | 1 | Firmware updates with progress |
All entities use the format: {type}.dongle_{mac_address}_{unique_id}
Where {mac_address} is the dongle's MAC address with colons replaced by underscores (e.g., 12_34_56_78_90_ab)
Example: sensor.dongle_12_34_56_78_90_ab_soc
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_ppv1 |
PV1 Power | W | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_ppv2 |
PV2 Power | W | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_ppv3 |
PV3 Power | W | FAAB, FAAA, EAAA, EAAB, HAAA |
sensor.dongle_XX_ppv1 |
PV Power (AC Coupled) | W | BAAA, BAAB |
sensor.dongle_XX_Pall |
Power PV All | W | All |
sensor.dongle_XX_pcharge |
Power Charge | W | All |
sensor.dongle_XX_pdischarge |
Power Discharge | W | All |
sensor.dongle_XX_pinv |
Power Inverter | W | All |
sensor.dongle_XX_prec |
Power Rectifier | W | All |
sensor.dongle_XX_peps |
Power EPS | W | All |
sensor.dongle_XX_ptogrid |
Power to Grid (live) | W | All |
sensor.dongle_XX_ptouser |
Power to User (live) | W | All |
sensor.dongle_XX_pload |
House Consumption (Live) | W | All |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_epv1_day |
Energy PV1 Day | kWh | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_epv1_day |
PV Energy Day (AC Coupled) | kWh | BAAA, BAAB |
sensor.dongle_XX_epv2_day |
Energy PV2 Day | kWh | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_epv3_day |
Energy PV3 Day | kWh | FAAB, FAAA, EAAA, EAAB, HAAA |
sensor.dongle_XX_epv_all |
Total PV Day | kWh | All |
sensor.dongle_XX_einv_day |
Energy Inverter Day | kWh | All |
sensor.dongle_XX_erec_day |
Energy Rectifier Day | kWh | All |
sensor.dongle_XX_echg_day |
Energy Charge Day | kWh | All |
sensor.dongle_XX_edischg_day |
Energy Discharge Day | kWh | All |
sensor.dongle_XX_eeps_day |
Energy EPS Day | kWh | All |
sensor.dongle_XX_etogrid_day |
Energy to Grid Day | kWh | All |
sensor.dongle_XX_etouser_day |
Energy to User Day | kWh | All |
sensor.dongle_XX_epv1_all |
Energy PV1 All | kWh | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_epv1_all |
PV Energy All (AC Coupled) | kWh | BAAA, BAAB |
sensor.dongle_XX_epv2_all |
Energy PV2 All | kWh | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_epv3_all |
Energy PV3 All | kWh | FAAB, FAAA, EAAA, EAAB, HAAA |
sensor.dongle_XX_einv_all |
Energy Inverter All | kWh | All |
sensor.dongle_XX_erec_all |
Energy Rectifier All | kWh | All |
sensor.dongle_XX_echg_all |
Energy Charge All | kWh | All |
sensor.dongle_XX_edischg_all |
Energy Discharge All | kWh | All |
sensor.dongle_XX_eeps_all |
Energy EPS All | kWh | All |
sensor.dongle_XX_etogrid_all |
Energy to Grid All | kWh | All |
sensor.dongle_XX_etouser_all |
Energy to User All | kWh | All |
sensor.dongle_XX_HourlyConsumption |
Hourly Consumption | kWh | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_DailyConsumption |
Daily Consumption | kWh | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_vpv1 |
Voltage PV1 | V | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_vpv2 |
Voltage PV2 | V | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa, HAAA, ceaa |
sensor.dongle_XX_vpv3 |
Voltage PV3 | V | FAAB, FAAA, EAAA, EAAB |
sensor.dongle_XX_vbat |
Voltage Battery | V | All |
sensor.dongle_XX_vacr |
Voltage AC R | V | All |
sensor.dongle_XX_vacs |
Voltage AC S | V | GAAB, GAAA |
sensor.dongle_XX_vact |
Voltage AC T | V | GAAB, GAAA |
sensor.dongle_XX_vepsr |
Voltage EPS R | V | All |
sensor.dongle_XX_vepss |
Voltage EPS S | V | GAAA, GAAB, FAAA, FAAB, EAAA, EAAB, ccaa, ceaa |
sensor.dongle_XX_vepst |
Voltage EPS T | V | GAAA, GAAB, FAAA, FAAB, EAAA, EAAB, ccaa, ceaa |
sensor.dongle_XX_vbus1 |
Voltage Bus 1 | V | All |
sensor.dongle_XX_vbus2 |
Voltage Bus 2 | V | All |
sensor.dongle_XX_ipv1 |
PV1 Current (calculated) | A | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa |
sensor.dongle_XX_ipv2 |
PV2 Current (calculated) | A | AAAA, AAAB, FAAA, FAAB, EAAA, EAAB, ccaa |
sensor.dongle_XX_ipv3 |
PV3 Current (calculated) | A | FAAB, FAAA, EAAA, EAAB |
sensor.dongle_XX_iinvrms |
Current Inverter RMS | A | All |
sensor.dongle_XX_fac |
Frequency AC | Hz | All |
sensor.dongle_XX_feps |
Frequency EPS | Hz | All |
sensor.dongle_XX_pf |
Power Factor | % | All |
sensor.dongle_XX_seps |
Apparent Power EPS | VA | All |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_soc |
State of Charge | % | All |
sensor.dongle_XX_soh |
State of Health | % | All |
sensor.dongle_XX_BatCapacity |
Battery Capacity (Ah) | Ah | All |
sensor.dongle_XX_BatCurrent_BMS |
Battery Current | A | All |
sensor.dongle_XX_MaxChgCurr |
Battery Max Charge Current | A | All |
sensor.dongle_XX_MaxDischgCurr |
Battery Max Discharge Current | A | All |
sensor.dongle_XX_ChargeVoltRef |
Battery Charge Voltage Ref | V | All |
sensor.dongle_XX_DischgCutVolt |
Battery Discharge Voltage Ref | V | All |
sensor.dongle_XX_BatStatus0_BMS |
Battery BMS Status 0 | - | All |
sensor.dongle_XX_BatStatus5_BMS |
Battery BMS Status 5 | - | All |
sensor.dongle_XX_BatStatus_INV |
Battery Status Aggregrate Value | - | All |
sensor.dongle_XX_BatParallelNum |
Number Of Batteries (Parallel) | - | All |
sensor.dongle_XX_FaultCode_BMS |
Battery Fault Code | - | All |
sensor.dongle_XX_WarningCode_BMS |
Battery Warning Code | - | All |
sensor.dongle_XX_MaxCellVolt_BMS |
Max Cell Voltage | V | All |
sensor.dongle_XX_MinCellVolt_BMS |
Min Cell Voltage | V | All |
sensor.dongle_XX_MaxCellTemp_BMS |
Max Cell Temperature | °C | All |
sensor.dongle_XX_MinCellTemp_BMS |
Min Cell Temperature | °C | All |
sensor.dongle_XX_CycleCnt_BMS |
Battery Cycle Count | - | All |
sensor.dongle_XX_BatVoltSample_INV |
Inverter Battery Voltage Sample | V | All |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_tinner |
Internal Temperature | °C | All |
sensor.dongle_XX_tradiator1 |
Radiator Temperature 1 | °C | All |
sensor.dongle_XX_tradiator2 |
Radiator Temperature 2 | °C | E, F, G |
sensor.dongle_XX_tbat |
Battery Temperature | °C | All |
sensor.dongle_XX_MaxCellTemp_BMS |
Max Cell Temperature | °C | All |
sensor.dongle_XX_MinCellTemp_BMS |
Min Cell Temperature | °C | All |
sensor.dongle_XX_T1 |
Radiator T1 | °C | FAAB, FAAA |
sensor.dongle_XX_T2 |
Radiator T2 | °C | FAAB, FAAA |
sensor.dongle_XX_T3 |
Radiator T3 | °C | FAAB, FAAA |
sensor.dongle_XX_T4 |
Radiator T4 | °C | FAAB, FAAA |
| Entity ID | Description | Values | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_state |
State | Various states | All |
sensor.dongle_XX_statedescription |
Working Mode | Various modes | All |
sensor.dongle_XX_fault_status |
Fault Status | Text | All |
sensor.dongle_XX_warning_status |
Warning Status | Text | All |
sensor.dongle_XX_FaultCode |
Fault Code | Text | All |
sensor.dongle_XX_WarningCode |
Warning Code | Text | All |
sensor.dongle_XX_internalfault |
Internal Fault | - | All |
sensor.dongle_XX_uptime |
Uptime Sensor | seconds | All |
sensor.dongle_XX_RunningTime |
Running Time | seconds | All |
sensor.dongle_XX_MasterOrSlave |
Master or Slave Device | Text | All |
sensor.dongle_XX_FWCode |
FWCode | - | All |
sensor.dongle_XX_SlaveVer |
Slave Version | Text | All |
sensor.dongle_XX_ComVer |
Com Version | Text | All |
sensor.dongle_XX_CntlVer |
Control Version | Text | All |
sensor.dongle_XX_FWVer |
FW Version | Text | All |
sensor.dongle_XX_last_bank_update |
Last Bank Update | timestamp | All |
| Entity ID | Description | States | Firmware Codes |
|---|---|---|---|
binary_sensor.dongle_XX_battery_charge_status |
Battery Charge | on/off | All |
binary_sensor.dongle_XX_battery_discharge_status |
Battery Discharge | on/off | All |
| Entity ID | Description | Function | Firmware Codes |
|---|---|---|---|
switch.dongle_XX_ResetSetting |
Restart Inverter | Restart inverter | All |
switch.dongle_XX_EPS |
EPS | Enable emergency power | All |
switch.dongle_XX_NeutralDetect |
Ground neutral detection enable | Enable neutral detection | All |
switch.dongle_XX_ACCharge |
AC Charge | Allow grid charging | All |
switch.dongle_XX_SWSeamlessly |
Seamless off-grid mode switching | Enable seamless switching | All |
switch.dongle_XX_SetToStandby |
Standby Switch | Set to standby mode | All |
switch.dongle_XX_ForcedDischg |
Force Discharge | Force battery discharge | All |
switch.dongle_XX_ForcedChg |
Charge Priority | Battery/Load priority | All |
switch.dongle_XX_FeedInGrid |
Export Allowed | Allow export to grid | All |
| Entity ID | Description | Function | Firmware Codes |
|---|---|---|---|
switch.dongle_XX_ubPVGridOffEn |
PV Grid Off | Disable PV when grid off | All |
switch.dongle_XX_ubFastZeroExport |
Fast Zero Export | Enable fast zero export | All |
switch.dongle_XX_ubMicroGridEn |
Micro Grid On | Enable micro grid mode | All |
switch.dongle_XX_ubBatShared |
Battery Shared | Enable battery sharing | All |
switch.dongle_XX_ubChgLastEn |
Charge Last | Enable charge last mode | All |
switch.dongle_XX_TakeLoadTogether |
Take Load Together | Enable load sharing | All |
switch.dongle_XX_HalfHourACChrStartEn |
Half hour charge Switch | Enable half-hour charging | All |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_ActivePowerPercentCMD |
0-100% | Active Power | All |
number.dongle_XX_ChargePowerPercentCMD |
0-100% | Charge Power Rate | All |
number.dongle_XX_DischgPowerPercentCMD |
0-100% | Discharge Power Rate | All |
number.dongle_XX_ACChgPowerCMD |
0-100% | AC Charge Rate | All |
number.dongle_XX_ChgFirstPowerCMD |
0-100% | Charge First Rate | All |
number.dongle_XX_ForcedDischgPowerCMD |
0-100% | Force Discharge Power Rate | All |
number.dongle_XX_ForcedDischgSOCLimit |
0-100% | Force Discharge SOC Limit | All |
number.dongle_XX_DischgCurr |
0-140A | Discharge Current DC(A) | All |
number.dongle_XX_ChargeCurr |
0-140A | Charge Current DC(A) | All |
number.dongle_XX_ChargeRate |
0-140A | Lead acid Charge Rate (A) | All |
number.dongle_XX_DischgRate |
0-140A | Lead Acid Discharge Rate (A) | All |
number.dongle_XX_PtoUserStartdischg |
1-50W | Battery Discharge Start Point (W) | All |
number.dongle_XX_PtoUserStartchg |
-50-1W | Battery Charge Start Point (W) | All |
number.dongle_XX_wCT_PowerOffset |
0-1000W | CT Offset (W) | All |
number.dongle_XX_MaxBackFlow |
0-200W | Export Power (%) | All |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_ACChgSOCLimit |
0-100% | AC Charge SOC Limit | All |
number.dongle_XX_ChgFirstSOCLimit |
0-100% | Charge First SOC Limit | All |
number.dongle_XX_EOD |
0-90% | On-grid Discharge Cut-off SOC Limit | All |
number.dongle_XX_SOCLowLimitForESPSDischg |
0-90% | Off-grid Discharge Cut-off SOC Limit | All |
number.dongle_XX_ACChgStartSOC |
0-100% | AC Charge Start (SOC) | All |
number.dongle_XX_ACChgEndSOC |
0-100% | AC Charge End (SOC) | All |
number.dongle_XX_ACChgStartVolt |
38.5-52V | AC Charge Start (Voltage) | All |
number.dongle_XX_ACChgEndVolt |
48-59V | AC Charge End (Voltage) | All |
number.dongle_XX_BatStopChgSOC |
0-101% | System Charge SOC Limit % | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_BatStopChgVolt |
40-56V | System Charge Volt limit (v) | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_ForceDichgEndVolt |
40-56V | Stop Discharge (Voltage) | All |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_MaxGridInputPower |
0-24kW | Max Grid Input Power | All |
number.dongle_XX_GenRatePower |
0-24kW | Generator Rated Input Power | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_GenChgStartVolt |
40-56V | Generator Charge Start Voltage | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_GenChgEndVolt |
50-60V | Generator Charge End Voltage | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_GenChgStartSOC |
0-100% | Generator Charge Start SOC | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_GenChgEndSOC |
0-100% | Generator Charge End SOC | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_MaxGenChgBatCurr |
0-140A | Max Generator Charge Battery Current | HAAA, FAAA, FAAB, ccaa, ceaa |
number.dongle_XX_GenChgStartCurr |
0-140A | Generator Charge Start Current | HAAA, FAAA, FAAB, ccaa, ceaa |
| Entity ID | Format | Description | Firmware Codes |
|---|---|---|---|
time.dongle_XX_ACChgStart |
HH:MM | AC Charge Start | All |
time.dongle_XX_ACChgEnd |
HH:MM | AC Charge End | All |
time.dongle_XX_ACChgStart1 |
HH:MM | AC Charge Start1 | All |
time.dongle_XX_ACChgEnd1 |
HH:MM | AC Charge End1 | All |
time.dongle_XX_ACChgStart2 |
HH:MM | AC Charge Start2 | All |
time.dongle_XX_ACChgEnd2 |
HH:MM | AC Charge End2 | All |
time.dongle_XX_ChgFirstStart |
HH:MM | Charge Priority Start | All |
time.dongle_XX_ChgFirstEnd |
HH:MM | Charge Priority End | All |
time.dongle_XX_ChgFirstStart1 |
HH:MM | Charge Priority Start1 | All |
time.dongle_XX_ChgFirstEnd1 |
HH:MM | Charge Priority End1 | All |
time.dongle_XX_ChgFirstStart2 |
HH:MM | Charge Priority Start2 | All |
time.dongle_XX_ChgFirstEnd2 |
HH:MM | Charge Priority End2 | All |
| Entity ID | Format | Description | Firmware Codes |
|---|---|---|---|
time.dongle_XX_ForcedDischgStart |
HH:MM | Force Discharge Start | All |
time.dongle_XX_ForcedDischgEnd |
HH:MM | Force Discharge End | All |
time.dongle_XX_ForcedDischgStart1 |
HH:MM | Force Discharge Start1 | All |
time.dongle_XX_ForcedDischgEnd1 |
HH:MM | Force Discharge End1 | All |
time.dongle_XX_ForcedDischgStart2 |
HH:MM | Force Discharge Start2 | All |
time.dongle_XX_ForcedDischgEnd2 |
HH:MM | Force Discharge End2 | All |
| Entity ID | Description | Options | Firmware Codes |
|---|---|---|---|
select.dongle_XX_Time0 |
00:00-00:30 | Does Not Operate, AC Charge, PV Charge, Discharge | All |
select.dongle_XX_Time1 |
00:30-01:00 | Does Not Operate, AC Charge, PV Charge, Discharge | All |
| ... | ... | ... | ... |
select.dongle_XX_Time47 |
23:30-00:00 | Does Not Operate, AC Charge, PV Charge, Discharge | All |
| Entity ID | Description | Options | Firmware Codes |
|---|---|---|---|
select.dongle_XX_CTSampleRatio |
CT Sample Ratio | 1:1000, 1:3000 | All |
select.dongle_XX_ClearParallelAlarm |
Clear Parallel Alarm | N/A, Clear | All |
select.dongle_XX_ACChargeType |
Charge Based on | Time According To, SOC/Volt According To | AAAA, AAAB, BAAA, BAAB |
select.dongle_XX_ACChargeType |
Charge Based on | Time According To, SOC/Volt According To, Time and SOC/Volt According To | ccaa, FAAB, FAAA, EAAA, EAAB, HAAA, ceaa |
select.dongle_XX_ubBatChgcontrol |
Charge Control | Voltage, SOC | All |
select.dongle_XX_ubBatDischgControl |
Discharge Control | Voltage, SOC | All |
select.dongle_XX_quickchgtime |
Quick Charge Duration | 0, 15, 30, 45, 60, 90, 120 | All |
| Entity ID | Description | Action | Firmware Codes |
|---|---|---|---|
button.dongle_XX_firmware_update_button |
Dongle Firmware Update | Updates dongle firmware | All |
button.dongle_XX_INVReboot |
Restart Inverter | Reboots the inverter | All |
| Entity ID | Description | Features | Firmware Codes |
|---|---|---|---|
update.dongle_XX_firmware_update |
Firmware Update | Progress tracking, release notes | IAAB, AAAA, AAAB, BAAA, BAAB, ccaa, FAAB, FAAA, EAAA, EAAB, HAAA, ceaa |
GridBoss adds 190+ entities for advanced distribution control. All GridBoss entities are only available with IAAB firmware.
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_midboxStatus |
GridBoss Status | Text | IAAB |
sensor.dongle_XX_gridRMSVoltage |
Grid RMS Voltage | V | IAAB |
sensor.dongle_XX_buRMSVoltage |
BU RMS Voltage | V | IAAB |
sensor.dongle_XX_genRMSVoltage |
Gen RMS Voltage | V | IAAB |
sensor.dongle_XX_PhaseLockFreq |
Phase Lock Frequency | Hz | IAAB |
sensor.dongle_XX_GridFreq |
Grid Frequency | Hz | IAAB |
sensor.dongle_XX_GenFreq |
Gen Frequency | Hz | IAAB |
sensor.dongle_XX_SmartPortMode |
Smart Port Mode | Text | IAAB |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_gridL1RMSVoltage |
Grid L1 RMS Voltage | V | IAAB |
sensor.dongle_XX_gridL2RMSVoltage |
Grid L2 RMS Voltage | V | IAAB |
sensor.dongle_XX_buL1RMSVoltage |
BU L1 RMS Voltage | V | IAAB |
sensor.dongle_XX_buL2RMSVoltage |
BU L2 RMS Voltage | V | IAAB |
sensor.dongle_XX_genL1RMSVoltage |
Gen L1 RMS Voltage | V | IAAB |
sensor.dongle_XX_genL2RMSVoltage |
Gen L2 RMS Voltage | V | IAAB |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_gridL1RMSCurrent |
Grid L1 RMS Current | A | IAAB |
sensor.dongle_XX_gridL2RMSCurrent |
Grid L2 RMS Current | A | IAAB |
sensor.dongle_XX_loadL1RMSCurrent |
Load L1 RMS Current | A | IAAB |
sensor.dongle_XX_loadL2RMSCurrent |
Load L2 RMS Current | A | IAAB |
sensor.dongle_XX_genL1RMSCurrent |
Gen L1 RMS Current | A | IAAB |
sensor.dongle_XX_genL2RMSCurrent |
Gen L2 RMS Current | A | IAAB |
sensor.dongle_XX_buL1RMSCurrent |
BU L1 RMS Current | A | IAAB |
sensor.dongle_XX_buL2RMSCurrent |
BU L2 RMS Current | A | IAAB |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_smartLoad1L1RMSCurrent |
SmartLoad1 L1 RMS Current | A | IAAB |
sensor.dongle_XX_smartLoad1L2RMSCurrent |
SmartLoad1 L2 RMS Current | A | IAAB |
sensor.dongle_XX_smartLoad2L1RMSCurrent |
SmartLoad2 L1 RMS Current | A | IAAB |
sensor.dongle_XX_smartLoad2L2RMSCurrent |
SmartLoad2 L2 RMS Current | A | IAAB |
sensor.dongle_XX_smartLoad3L1RMSCurrent |
SmartLoad3 L1 RMS Current | A | IAAB |
sensor.dongle_XX_smartLoad3L2RMSCurrent |
SmartLoad3 L2 RMS Current | A | IAAB |
sensor.dongle_XX_smartLoad4L1RMSCurrent |
SmartLoad4 L1 RMS Current | A | IAAB |
sensor.dongle_XX_smartLoad4L2RMSCurrent |
SmartLoad4 L2 RMS Current | A | IAAB |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_gridL1ActivePower |
Grid L1 Active Power | W | IAAB |
sensor.dongle_XX_gridL2ActivePower |
Grid L2 Active Power | W | IAAB |
sensor.dongle_XX_loadL1ActivePower |
Load L1 Active Power | W | IAAB |
sensor.dongle_XX_loadL2ActivePower |
Load L2 Active Power | W | IAAB |
sensor.dongle_XX_genL1ActivePower |
Gen L1 Active Power | W | IAAB |
sensor.dongle_XX_genL2ActivePower |
Gen L2 Active Power | W | IAAB |
sensor.dongle_XX_buL1ActivePower |
BU L1 Active Power | W | IAAB |
sensor.dongle_XX_buL2ActivePower |
BU L2 Active Power | W | IAAB |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_smartLoad1L1ActivePower |
SmartLoad1 L1 Active Power | W | IAAB |
sensor.dongle_XX_smartLoad1L2ActivePower |
SmartLoad1 L2 Active Power | W | IAAB |
sensor.dongle_XX_smartLoad2L1ActivePower |
SmartLoad2 L1 Active Power | W | IAAB |
sensor.dongle_XX_smartLoad2L2ActivePower |
SmartLoad2 L2 Active Power | W | IAAB |
sensor.dongle_XX_smartLoad3L1ActivePower |
SmartLoad3 L1 Active Power | W | IAAB |
sensor.dongle_XX_smartLoad3L2ActivePower |
SmartLoad3 L2 Active Power | W | IAAB |
sensor.dongle_XX_smartLoad4L1ActivePower |
SmartLoad4 L1 Active Power | W | IAAB |
sensor.dongle_XX_smartLoad4L2ActivePower |
SmartLoad4 L2 Active Power | W | IAAB |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_eLoad_TodayAll |
E Load Today All | kWh | IAAB |
sensor.dongle_XX_EtoGrid_TodayAll |
E to Grid Today All | kWh | IAAB |
sensor.dongle_XX_EtoUser_TodayAll |
E to User Today All | kWh | IAAB |
sensor.dongle_XX_Egen_TodayAll |
E Gen Today All | kWh | IAAB |
sensor.dongle_XX_ESmartLoad1_TodayAll |
E SmartLoad1 Today All | kWh | IAAB |
sensor.dongle_XX_ESmartLoad2_TodayAll |
E SmartLoad2 Today All | kWh | IAAB |
sensor.dongle_XX_ESmartLoad3_TodayAll |
E SmartLoad3 Today All | kWh | IAAB |
sensor.dongle_XX_ESmartLoad4_TodayAll |
E SmartLoad4 Today All | kWh | IAAB |
sensor.dongle_XX_EAcouple1_TodayAll |
E ACcouple1 Today All | kWh | IAAB |
sensor.dongle_XX_EAcouple2_TodayAll |
E ACcouple2 Today All | kWh | IAAB |
sensor.dongle_XX_EAcouple3_TodayAll |
E ACcouple3 Today All | kWh | IAAB |
sensor.dongle_XX_EAcouple4_TodayAll |
E ACcouple4 Today All | kWh | IAAB |
| Entity ID | Description | Unit | Firmware Codes |
|---|---|---|---|
sensor.dongle_XX_ELoad_total |
E Load Total | kWh | IAAB |
sensor.dongle_XX_EBU_Total |
E BU Total | kWh | IAAB |
sensor.dongle_XX_EtoGrid_total |
E to Grid Total | kWh | IAAB |
sensor.dongle_XX_EtoUser_total |
E to User Total | kWh | IAAB |
sensor.dongle_XX_Egen_total |
E Gen Total | kWh | IAAB |
sensor.dongle_XX_ESmartLoad1_total |
E SmartLoad1 Total | kWh | IAAB |
sensor.dongle_XX_ESmartLoad2_total |
E SmartLoad2 Total | kWh | IAAB |
sensor.dongle_XX_ESmartLoad3_total |
E SmartLoad3 Total | kWh | IAAB |
sensor.dongle_XX_ESmartLoad4_total |
E SmartLoad4 Total | kWh | IAAB |
sensor.dongle_XX_EAcouple1_total |
E ACcouple1 Total | kWh | IAAB |
sensor.dongle_XX_EAcouple2_total |
E ACcouple2 Total | kWh | IAAB |
sensor.dongle_XX_EAcouple3_total |
E ACcouple3 Total | kWh | IAAB |
sensor.dongle_XX_EAcouple4_total |
E ACcouple4 Total | kWh | IAAB |
sensor.dongle_XX_MIDBoox_ACType |
MIDBox AC Type | - | IAAB |
| Entity ID | Description | Function | Firmware Codes |
|---|---|---|---|
switch.dongle_XX_Generator_enable |
Generator Enable | Enable generator | IAAB |
| Entity ID | Description | Function | Firmware Codes |
|---|---|---|---|
switch.dongle_XX_SmartLoad1_Enable |
SmartLoad1 Enable | Enable SmartLoad1 | IAAB |
switch.dongle_XX_SmartLoad2_Enable |
SmartLoad2 Enable | Enable SmartLoad2 | IAAB |
switch.dongle_XX_SmartLoad3_Enable |
SmartLoad3 Enable | Enable SmartLoad3 | IAAB |
switch.dongle_XX_SmartLoad4_Enable |
SmartLoad4 Enable | Enable SmartLoad4 | IAAB |
switch.dongle_XX_SmartLoad1_GridOn |
SmartLoad1 Grid On | SmartLoad1 grid connection | IAAB |
switch.dongle_XX_SmartLoad2_GridOn |
SmartLoad2 Grid On | SmartLoad2 grid connection | IAAB |
switch.dongle_XX_SmartLoad3_GridOn |
SmartLoad3 Grid On | SmartLoad3 grid connection | IAAB |
switch.dongle_XX_SmartLoad4_GridOn |
SmartLoad4 Grid On | SmartLoad4 grid connection | IAAB |
switch.dongle_XX_SmartLoad1_Shedding |
SmartLoad1 Shedding | Enable SmartLoad1 shedding | IAAB |
switch.dongle_XX_SmartLoad2_Shedding |
SmartLoad2 Shedding | Enable SmartLoad2 shedding | IAAB |
switch.dongle_XX_SmartLoad3_Shedding |
SmartLoad3 Shedding | Enable SmartLoad3 shedding | IAAB |
switch.dongle_XX_SmartLoad4_Shedding |
SmartLoad4 Shedding | Enable SmartLoad4 shedding | IAAB |
| Entity ID | Description | Function | Firmware Codes |
|---|---|---|---|
switch.dongle_XX_ACcouple1_Enable |
ACcouple1 Enable | Enable AC coupling 1 | IAAB |
switch.dongle_XX_ACcouple2_Enable |
ACcouple2 Enable | Enable AC coupling 2 | IAAB |
switch.dongle_XX_ACcouple3_Enable |
ACcouple3 Enable | Enable AC coupling 3 | IAAB |
switch.dongle_XX_ACcouple4_Enable |
ACcouple4 Enable | Enable AC coupling 4 | IAAB |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_Generator_Warmup |
0-600s | Generator Warmup Time | IAAB |
number.dongle_XX_Generator_CoolDown |
0-600s | Generator Cool Down Time | IAAB |
number.dongle_XX_Generator_Exercise_Period |
0-365d | Generator Exercise Period | IAAB |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_SmartLoad1_StartSOC |
0-100% | SmartLoad1 Start SOC | IAAB |
number.dongle_XX_SmartLoad1_EndSOC |
0-100% | SmartLoad1 End SOC | IAAB |
number.dongle_XX_SmartLoad2_StartSOC |
0-100% | SmartLoad2 Start SOC | IAAB |
number.dongle_XX_SmartLoad2_EndSOC |
0-100% | SmartLoad2 End SOC | IAAB |
number.dongle_XX_SmartLoad3_StartSOC |
0-100% | SmartLoad3 Start SOC | IAAB |
number.dongle_XX_SmartLoad3_EndSOC |
0-100% | SmartLoad3 End SOC | IAAB |
number.dongle_XX_SmartLoad4_StartSOC |
0-100% | SmartLoad4 Start SOC | IAAB |
number.dongle_XX_SmartLoad4_EndSOC |
0-100% | SmartLoad4 End SOC | IAAB |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_SmartLoad1_StartVolt |
40-60V | SmartLoad1 Start Voltage | IAAB |
number.dongle_XX_SmartLoad1_EndVolt |
40-60V | SmartLoad1 End Voltage | IAAB |
number.dongle_XX_SmartLoad2_StartVolt |
40-60V | SmartLoad2 Start Voltage | IAAB |
number.dongle_XX_SmartLoad2_EndVolt |
40-60V | SmartLoad2 End Voltage | IAAB |
number.dongle_XX_SmartLoad3_StartVolt |
40-60V | SmartLoad3 Start Voltage | IAAB |
number.dongle_XX_SmartLoad3_EndVolt |
40-60V | SmartLoad3 End Voltage | IAAB |
number.dongle_XX_SmartLoad4_StartVolt |
40-60V | SmartLoad4 Start Voltage | IAAB |
number.dongle_XX_SmartLoad4_EndVolt |
40-60V | SmartLoad4 End Voltage | IAAB |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_ACcouple1_StartSOC |
0-100% | ACcouple1 Start SOC | IAAB |
number.dongle_XX_ACcouple1_EndSOC |
0-100% | ACcouple1 End SOC | IAAB |
number.dongle_XX_ACcouple2_StartSOC |
0-100% | ACcouple2 Start SOC | IAAB |
number.dongle_XX_ACcouple2_EndSOC |
0-100% | ACcouple2 End SOC | IAAB |
number.dongle_XX_ACcouple3_StartSOC |
0-100% | ACcouple3 Start SOC | IAAB |
number.dongle_XX_ACcouple3_EndSOC |
0-100% | ACcouple3 End SOC | IAAB |
number.dongle_XX_ACcouple4_StartSOC |
0-100% | ACcouple4 Start SOC | IAAB |
number.dongle_XX_ACcouple4_EndSOC |
0-100% | ACcouple4 End SOC | IAAB |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_ACcouple1_StartVolt |
40-60V | ACcouple1 Start Voltage | IAAB |
number.dongle_XX_ACcouple1_EndVolt |
40-60V | ACcouple1 End Voltage | IAAB |
number.dongle_XX_ACcouple2_StartVolt |
40-60V | ACcouple2 Start Voltage | IAAB |
number.dongle_XX_ACcouple2_EndVolt |
40-60V | ACcouple2 End Voltage | IAAB |
number.dongle_XX_ACcouple3_StartVolt |
40-60V | ACcouple3 Start Voltage | IAAB |
number.dongle_XX_ACcouple3_EndVolt |
40-60V | ACcouple3 End Voltage | IAAB |
number.dongle_XX_ACcouple4_StartVolt |
40-60V | ACcouple4 Start Voltage | IAAB |
number.dongle_XX_ACcouple4_EndVolt |
40-60V | ACcouple4 End Voltage | IAAB |
| Entity ID | Range | Description | Firmware Codes |
|---|---|---|---|
number.dongle_XX_SmartLoad1_SheddingStartPv_Power |
0-10000W | SmartLoad1 Shedding Start PV Power | IAAB |
number.dongle_XX_SmartLoad2_SheddingStartPv_Power |
0-10000W | SmartLoad2 Shedding Start PV Power | IAAB |
number.dongle_XX_SmartLoad3_SheddingStartPv_Power |
0-10000W | SmartLoad3 Shedding Start PV Power | IAAB |
number.dongle_XX_SmartLoad4_SheddingStartPv_Power |
0-10000W | SmartLoad4 Shedding Start PV Power | IAAB |
number.dongle_XX_SmartLoad1_SheddingStartSOC |
0-100% | SmartLoad1 Shedding Start SOC | IAAB |
number.dongle_XX_SmartLoad1_SheddingEndSOC |
0-100% | SmartLoad1 Shedding End SOC | IAAB |
number.dongle_XX_SmartLoad2_SheddingStartSOC |
0-100% | SmartLoad2 Shedding Start SOC | IAAB |
number.dongle_XX_SmartLoad2_SheddingEndSOC |
0-100% | SmartLoad2 Shedding End SOC | IAAB |
number.dongle_XX_SmartLoad3_SheddingStartSOC |
0-100% | SmartLoad3 Shedding Start SOC | IAAB |
number.dongle_XX_SmartLoad3_SheddingEndSOC |
0-100% | SmartLoad3 Shedding End SOC | IAAB |
number.dongle_XX_SmartLoad4_SheddingStartSOC |
0-100% | SmartLoad4 Shedding Start SOC | IAAB |
number.dongle_XX_SmartLoad4_SheddingEndSOC |
0-100% | SmartLoad4 Shedding End SOC | IAAB |
number.dongle_XX_SmartLoad1_SheddingStartVolt |
40-60V | SmartLoad1 Shedding Start Voltage | IAAB |
number.dongle_XX_SmartLoad1_SheddingEndVolt |
40-60V | SmartLoad1 Shedding End Voltage | IAAB |
number.dongle_XX_SmartLoad2_SheddingStartVolt |
40-60V | SmartLoad2 Shedding Start Voltage | IAAB |
number.dongle_XX_SmartLoad2_SheddingEndVolt |
40-60V | SmartLoad2 Shedding End Voltage | IAAB |
number.dongle_XX_SmartLoad3_SheddingStartVolt |
40-60V | SmartLoad3 Shedding Start Voltage | IAAB |
number.dongle_XX_SmartLoad3_SheddingEndVolt |
40-60V | SmartLoad3 Shedding End Voltage | IAAB |
number.dongle_XX_SmartLoad4_SheddingStartVolt |
40-60V | SmartLoad4 Shedding Start Voltage | IAAB |
number.dongle_XX_SmartLoad4_SheddingEndVolt |
40-60V | SmartLoad4 Shedding End Voltage | IAAB |
number.dongle_XX_Flash_5060hz |
0-1 | Flash 50/60Hz | IAAB |
number.dongle_XX_NEC_120CurrLimit |
0-200A | NEC 120 Current Limit | IAAB |
| Entity ID | Description | Options | Firmware Codes |
|---|---|---|---|
select.dongle_XX_SmartLoad1_PortMode |
Smart Port 1 | Does Not Operate, Smart Load, Ac Coupled | IAAB |
select.dongle_XX_SmartLoad2_PortMode |
Smart Port 2 | Does Not Operate, Smart Load, Ac Coupled | IAAB |
select.dongle_XX_SmartLoad3_PortMode |
Smart Port 3 | Does Not Operate, Smart Load, Ac Coupled | IAAB |
select.dongle_XX_SmartLoad4_PortMode |
Smart Port 4 | Does Not Operate, Smart Load, Ac Coupled | IAAB |
| Entity ID | Description | Options | Firmware Codes |
|---|---|---|---|
select.dongle_XX_SmartLoad1_SOC_Volt |
Smart Load 1 Mode | Time, SOC/Volt | IAAB |
select.dongle_XX_SmartLoad2_SOC_Volt |
Smart Load 2 Mode | Time, SOC/Volt | IAAB |
select.dongle_XX_SmartLoad3_SOC_Volt |
Smart Load 3 Mode | Time, SOC/Volt | IAAB |
select.dongle_XX_SmartLoad4_SOC_Volt |
Smart Load 4 Mode | Time, SOC/Volt | IAAB |
| Entity ID | Format | Description | Firmware Codes |
|---|---|---|---|
time.dongle_XX_SmartLoad1Start0 |
HH:MM | SmartLoad1 Start0 | IAAB |
time.dongle_XX_SmartLoad1End0 |
HH:MM | SmartLoad1 End0 | IAAB |
time.dongle_XX_SmartLoad1Start1 |
HH:MM | SmartLoad1 Start1 | IAAB |
time.dongle_XX_SmartLoad1End1 |
HH:MM | SmartLoad1 End1 | IAAB |
time.dongle_XX_SmartLoad1Start2 |
HH:MM | SmartLoad1 Start2 | IAAB |
time.dongle_XX_SmartLoad1End2 |
HH:MM | SmartLoad1 End2 | IAAB |
time.dongle_XX_SmartLoad2Start0 |
HH:MM | SmartLoad2 Start0 | IAAB |
time.dongle_XX_SmartLoad2End0 |
HH:MM | SmartLoad2 End0 | IAAB |
time.dongle_XX_SmartLoad2Start1 |
HH:MM | SmartLoad2 Start1 | IAAB |
time.dongle_XX_SmartLoad2End1 |
HH:MM | SmartLoad2 End1 | IAAB |
time.dongle_XX_SmartLoad2Start2 |
HH:MM | SmartLoad2 Start2 | IAAB |
time.dongle_XX_SmartLoad2End2 |
HH:MM | SmartLoad2 End2 | IAAB |
time.dongle_XX_SmartLoad3Start0 |
HH:MM | SmartLoad3 Start0 | IAAB |
time.dongle_XX_SmartLoad3End0 |
HH:MM | SmartLoad3 End0 | IAAB |
time.dongle_XX_SmartLoad3Start1 |
HH:MM | SmartLoad3 Start1 | IAAB |
time.dongle_XX_SmartLoad3End1 |
HH:MM | SmartLoad3 End1 | IAAB |
time.dongle_XX_SmartLoad3Start2 |
HH:MM | SmartLoad3 Start2 | IAAB |
time.dongle_XX_SmartLoad3End2 |
HH:MM | SmartLoad3 End2 | IAAB |
time.dongle_XX_SmartLoad4Start0 |
HH:MM | SmartLoad4 Start0 | IAAB |
time.dongle_XX_SmartLoad4End0 |
HH:MM | SmartLoad4 End0 | IAAB |
time.dongle_XX_SmartLoad4Start1 |
HH:MM | SmartLoad4 Start1 | IAAB |
time.dongle_XX_SmartLoad4End1 |
HH:MM | SmartLoad4 End1 | IAAB |
time.dongle_XX_SmartLoad4Start2 |
HH:MM | SmartLoad4 Start2 | IAAB |
time.dongle_XX_SmartLoad4End2 |
HH:MM | SmartLoad4 End2 | IAAB |
| Entity ID | Format | Description | Firmware Codes |
|---|---|---|---|
time.dongle_XX_ACcouple1Start0 |
HH:MM | ACcouple1 Start0 | IAAB |
time.dongle_XX_ACcouple1End0 |
HH:MM | ACcouple1 End0 | IAAB |
time.dongle_XX_ACcouple1Start1 |
HH:MM | ACcouple1 Start1 | IAAB |
time.dongle_XX_ACcouple1End1 |
HH:MM | ACcouple1 End1 | IAAB |
time.dongle_XX_ACcouple1Start2 |
HH:MM | ACcouple1 Start2 | IAAB |
time.dongle_XX_ACcouple1End2 |
HH:MM | ACcouple1 End2 | IAAB |
time.dongle_XX_ACcouple2Start0 |
HH:MM | ACcouple2 Start0 | IAAB |
time.dongle_XX_ACcouple2End0 |
HH:MM | ACcouple2 End0 | IAAB |
time.dongle_XX_ACcouple2Start1 |
HH:MM | ACcouple2 Start1 | IAAB |
time.dongle_XX_ACcouple2End1 |
HH:MM | ACcouple2 End1 | IAAB |
time.dongle_XX_ACcouple2Start2 |
HH:MM | ACcouple2 Start2 | IAAB |
time.dongle_XX_ACcouple2End2 |
HH:MM | ACcouple2 End2 | IAAB |
time.dongle_XX_ACcouple3Start0 |
HH:MM | ACcouple3 Start0 | IAAB |
time.dongle_XX_ACcouple3End0 |
HH:MM | ACcouple3 End0 | IAAB |
time.dongle_XX_ACcouple3Start1 |
HH:MM | ACcouple3 Start1 | IAAB |
time.dongle_XX_ACcouple3End1 |
HH:MM | ACcouple3 End1 | IAAB |
time.dongle_XX_ACcouple3Start2 |
HH:MM | ACcouple3 Start2 | IAAB |
time.dongle_XX_ACcouple3End2 |
HH:MM | ACcouple3 End2 | IAAB |
time.dongle_XX_ACcouple4Start0 |
HH:MM | ACcouple4 Start0 | IAAB |
time.dongle_XX_ACcouple4End0 |
HH:MM | ACcouple4 End0 | IAAB |
time.dongle_XX_ACcouple4Start1 |
HH:MM | ACcouple4 Start1 | IAAB |
time.dongle_XX_ACcouple4End1 |
HH:MM | ACcouple4 End1 | IAAB |
time.dongle_XX_ACcouple4Start2 |
HH:MM | ACcouple4 Start2 | IAAB |
time.dongle_XX_ACcouple4End2 |
HH:MM | ACcouple4 End2 | IAAB |
When multiple inverters are configured, combined entities are created automatically. These entities aggregate data from all configured dongles and provide unified control.
All power and energy sensors have combined versions that sum values from all dongles:
-
sensor.combined_ppv1- Total PV1 power -
sensor.combined_ppv2- Total PV2 power -
sensor.combined_ppv3- Total PV3 power -
sensor.combined_Pall- Total PV power -
sensor.combined_pcharge- Total charge power -
sensor.combined_pdischarge- Total discharge power -
sensor.combined_pload- Total load power -
sensor.combined_ptogrid- Total grid power -
sensor.combined_ptouser- Total user power -
sensor.combined_peps- Total EPS power
-
sensor.combined_epv1_day- Total PV1 energy today -
sensor.combined_epv2_day- Total PV2 energy today -
sensor.combined_epv3_day- Total PV3 energy today -
sensor.combined_epv_all- Total PV energy today -
sensor.combined_echg_day- Total charge energy today -
sensor.combined_edischg_day- Total discharge energy today -
sensor.combined_etogrid_day- Total grid energy today -
sensor.combined_etouser_day- Total user energy today
All switches and numbers have combined versions that control all inverters simultaneously:
-
switch.combined_EPS- Control EPS on all inverters -
switch.combined_ACCharge- Control AC charging on all inverters -
switch.combined_ForcedDischg- Control forced discharge on all inverters -
switch.combined_ForcedChg- Control charge priority on all inverters -
number.combined_ActivePowerPercentCMD- Set active power on all inverters -
number.combined_ChargePowerPercentCMD- Set charge power on all inverters -
number.combined_DischgPowerPercentCMD- Set discharge power on all inverters -
number.combined_ACChgPowerCMD- Set AC charge power on all inverters
For GridBoss systems, additional combined entities are created:
-
switch.combined_Generator_enable- Control generator on all GridBoss units -
switch.combined_SmartLoad1_Enable- Control SmartLoad1 on all units -
switch.combined_SmartLoad2_Enable- Control SmartLoad2 on all units -
switch.combined_SmartLoad3_Enable- Control SmartLoad3 on all units -
switch.combined_SmartLoad4_Enable- Control SmartLoad4 on all units
Many entities include additional attributes:
sensor.dongle_XX_ppv:
state: 3500
attributes:
unit_of_measurement: W
device_class: power
state_class: measurement
last_updated: 2024-01-15 10:30:00sensor.dongle_XX_fault_status:
state: "No Fault"
attributes:
value: 0
description: null
start_time: null
end_time: nullsensor.dongle_XX_bms_battery_voltage:
state: 52.4
attributes:
cell_voltages: [3.35, 3.34, 3.35, ...]
min_cell_voltage: 3.34
max_cell_voltage: 3.35Different firmware codes enable different entities. The integration uses a conditional entity system that automatically shows/hides entities based on your inverter's firmware code.
| Firmware Code | Model Type | Key Features |
|---|---|---|
| AAAA | 3-6k Hybrid Standard | Basic hybrid functionality, 2 PV strings |
| AAAB | 3-6k Hybrid Parallel | Parallel inverter support, 2 PV strings |
| BAAA | AC Coupled Standard | AC coupling support, 1 PV string |
| BAAB | AC Coupled Parallel | AC coupling with parallel support |
| ccaa | 6-12k Standard | Higher power capacity, 2 PV strings |
| ceaa | Off Grid | Off-grid operation, 2 PV strings |
| EAAA | 8-10k Hybrid Standard | High power hybrid, 2 PV strings |
| EAAB | 8-10k Hybrid Parallel | High power parallel, 2 PV strings |
| FAAA | 12k Hybrid Standard | 12kW capacity, 3 PV strings |
| FAAB | 12k Hybrid Parallel | 12kW parallel, 3 PV strings |
| HAAA | Gen Models | Generator support, 2 PV strings |
| IAAB | GridBoss | Advanced distribution control, 190+ entities |
- 1 String: BAAA, BAAB
- 2 Strings: AAAA, AAAB, ccaa, ceaa, EAAA, EAAB, HAAA
- 3 Strings: FAAA, FAAB
- Generator Support: HAAA, FAAA, FAAB, ccaa, ceaa
- GridBoss Features: IAAB only
- 3-Phase Support: GAAB, GAAA (not in current const.py)
- AC Coupling: BAAA, BAAB, IAAB
The integration automatically manages entity availability based on your firmware code:
- Available Entities: Shown normally and fully functional
- Unavailable Entities: Grayed out and disabled in the UI
- Dynamic Updates: Entities appear/disappear when firmware is updated
This prevents configuration errors and provides clear visual feedback about which features are available for your specific inverter model.
The integration provides several calculated sensors for enhanced monitoring:
| Entity ID | Description | Attributes |
|---|---|---|
sensor.dongle_XX_battery_time_empty |
Battery Time to Empty | calculated_kwh_storage_total, calculated_kwh_left, time_battery_empty, human_readable_time_left |
| Entity ID | Description | Attributes |
|---|---|---|
sensor.dongle_XX_gridflow_live |
Grid Flow Live | ptouser, ptogrid |
sensor.dongle_XX_batteryflow_live |
Battery Flow Live | pdischarge, pcharge |
automation:
- trigger:
- platform: numeric_state
entity_id: sensor.dongle_12_34_56_78_90_ab_soc
below: 20
action:
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_ACChargescript:
charge_to_80:
sequence:
- service: number.set_value
target:
entity_id: number.dongle_12_34_56_78_90_ab_ACChgSOCLimit
data:
value: 80template:
- sensor:
- name: "Battery Power kW"
unit_of_measurement: "kW"
state: >
{{ (states('sensor.dongle_12_34_56_78_90_ab_pcharge')|float / 1000)|round(2) }}automation:
- trigger:
- platform: numeric_state
entity_id: sensor.dongle_12_34_56_78_90_ab_soc
below: 30
action:
- service: switch.turn_on
entity_id: switch.dongle_12_34_56_78_90_ab_Generator_enable- Use state_class: For energy tracking in statistics
- Monitor availability: Check for unavailable states
- Handle units: Convert W to kW for display
- Group related: Create entity groups for organization
- Template carefully: Add error handling to templates
- Firmware awareness: Check firmware code before using advanced features
- GridBoss features: Use conditional logic for GridBoss-specific entities
- Combined entities: Use combined entities for multi-inverter setups